👉What is a Dispute?
▶️Many construction disputes arise out of terms set forth in the contract. Unfortunately, many construction contracts were never reviewed by a construction attorney and are not models of clarity. Because many disputes are won or lost depending on the interpretation of the contract terms, it is imperative that those in the construction industry have in their skill set at least a basic knowledge of the rules and law governing contract interpretation. A claim has to be made before a dispute can arise. The dispute comes into being when the claim is not admitted and the claimant does not accept its rejection.
There are innumerable ways of not admitting a claim. The most obvious is a formal rejection. Discussions may follow the submission of a claim during which it becomes evident that the claim is not accepted; procrastination or prevarication on the part of the respondent will permit the inference that the claim is not accepted; or the respondent may simply not respond to the claim, with a similar result.
The time for which a respondent may remain silent before a dispute can be inferred varies and is dependent upon the contract as well as the facts of the case. An engineer has an obligation to consider a claim independently and to respond in a professional manner; this requires a reasonable length of time before the existence of a dispute can be inferred.
The imposition of a deadline by a claimant cannot cut short the reasonable time necessary to respond to a claim. However, a stated deadline and the reasons for it may have weight when establishing what a reasonable time for a response is.
The claim must be sufficiently well defined for a sensible response to be formulated. If it is not, a failure to respond or an outright rejection of the claim will not necessarily give rise to a dispute.
.
@etconp
▶️Many construction disputes arise out of terms set forth in the contract. Unfortunately, many construction contracts were never reviewed by a construction attorney and are not models of clarity. Because many disputes are won or lost depending on the interpretation of the contract terms, it is imperative that those in the construction industry have in their skill set at least a basic knowledge of the rules and law governing contract interpretation. A claim has to be made before a dispute can arise. The dispute comes into being when the claim is not admitted and the claimant does not accept its rejection.
There are innumerable ways of not admitting a claim. The most obvious is a formal rejection. Discussions may follow the submission of a claim during which it becomes evident that the claim is not accepted; procrastination or prevarication on the part of the respondent will permit the inference that the claim is not accepted; or the respondent may simply not respond to the claim, with a similar result.
The time for which a respondent may remain silent before a dispute can be inferred varies and is dependent upon the contract as well as the facts of the case. An engineer has an obligation to consider a claim independently and to respond in a professional manner; this requires a reasonable length of time before the existence of a dispute can be inferred.
The imposition of a deadline by a claimant cannot cut short the reasonable time necessary to respond to a claim. However, a stated deadline and the reasons for it may have weight when establishing what a reasonable time for a response is.
The claim must be sufficiently well defined for a sensible response to be formulated. If it is not, a failure to respond or an outright rejection of the claim will not necessarily give rise to a dispute.
.
@etconp
Forwarded from Ethio Construction Engineering (Fîłmøñ Łûël)
Forwarded from Ethio Construction Engineering (Fîłmøñ Łûël)
Forwarded from Ethio Construction Engineering (Fîłmøñ Łûël)
Honeycombs are hollow spaces and cavities left in
concrete mass on surface or inside the concrete mass where concrete could not reach. These look like honey bees nest.
Honeycombs which are on sides are visible to naked eyes and can be detected easily as soon shuttering is removed. Honey combs which are inside mass of concrete can only be detected by advanced techniques.
There are many reasons for Honeycombs the main reasons are:
1) Improper vibration during concrete.
2) Less cover to reinforcement bars.
3) Use of very stiff concrete (this can be avoided by
controlling water as per slump test).
4) Places like junction of beam to beam to column
and to one or more beams are the typical spots where honey combs are observed. This is due to jumbling of reinforcement of beams and column rods at one place; special attention is required at such place during concreting and vibrating.
5) Presence of more percentage of bigger size of aggregate in concrete also prevents concrete to fill narrow spaces between the Rc.
concrete mass on surface or inside the concrete mass where concrete could not reach. These look like honey bees nest.
Honeycombs which are on sides are visible to naked eyes and can be detected easily as soon shuttering is removed. Honey combs which are inside mass of concrete can only be detected by advanced techniques.
There are many reasons for Honeycombs the main reasons are:
1) Improper vibration during concrete.
2) Less cover to reinforcement bars.
3) Use of very stiff concrete (this can be avoided by
controlling water as per slump test).
4) Places like junction of beam to beam to column
and to one or more beams are the typical spots where honey combs are observed. This is due to jumbling of reinforcement of beams and column rods at one place; special attention is required at such place during concreting and vibrating.
5) Presence of more percentage of bigger size of aggregate in concrete also prevents concrete to fill narrow spaces between the Rc.
Forwarded from Ethio Construction Engineering (Fîłmøñ Łûël)
Forwarded from Ethio Construction Engineering (Fîłmøñ Łûël)
Forwarded from Ethio Construction Engineering (Fîłmøñ Łûël)
Forwarded from Ethio Construction Engineering (Fîłmøñ Łûël)
Forwarded from Ethio Construction Engineering (Fîłmøñ Łûël)
Forwarded from Ethio Construction Engineering (Fîłmøñ Łûël)
Forwarded from Ethio Construction Engineering (Fîłmøñ Łûël)
Forwarded from Ethio Construction Engineering (Fîłmøñ Łûël)
Forwarded from Ethio Construction Engineering (Fîłmøñ Łûël)
Forwarded from Ethio Construction Engineering (Fîłmøñ Łûël)
Forwarded from Ethio Construction Engineering (Fîłmøñ Łûël)
👉For Fun ... @COTMp
.
Question. : - What did the Steel say to the Concrete?
Answer. : - Don't take the Tension Bro.
.
*Column to Beam
Hey Bro, Whats up??
Beam: just enjoying "Moments"
.
*What did Reinforcement say to Concrete?
Just give me a Cover Bro!
.
*Coarse Aggregate to Sand: How are you, Bro?.
Sand: I am fine
.
✌The uniqueness of this joke can be understood
only by *CONSTRUCTION ENGINEERS...*
.
Question. : - What did the Steel say to the Concrete?
Answer. : - Don't take the Tension Bro.
.
*Column to Beam
Hey Bro, Whats up??
Beam: just enjoying "Moments"
.
*What did Reinforcement say to Concrete?
Just give me a Cover Bro!
.
*Coarse Aggregate to Sand: How are you, Bro?.
Sand: I am fine
.
✌The uniqueness of this joke can be understood
only by *CONSTRUCTION ENGINEERS...*
Forwarded from Ethio Construction Engineering (Fîłmøñ Łûël)
👉 ውድ ተከታዮቻችን እስቲ ኣሁን ደሞ የ @COTMp "Tip" ይሀው...
.
*ለሳኒቴሪ ገጠማ (installation) የሚያስፈልጉ የባኞ ቤት ስታንዳርድ
.
*Standards for bathroom and toilet.
.
*ለሳኒቴሪ ገጠማ (installation) የሚያስፈልጉ የባኞ ቤት ስታንዳርድ
.
*Standards for bathroom and toilet.
Forwarded from Ethio Construction Engineering
👉እናስተዋውቅዎ @COTMp
*ይህ ከላይ የምታዩት Cold Planer ይባላል።
የአስፓልትን layer በፈለግነው ጥልቀት በመቁረጥ እላያቸው ላይ በተገጠመላቸው conveyor ወደ ጭነት መኪናዎች የሚጭኑ ለአስፓልት maintenance የምንጠቀምባቸው አስፓልት
መቁረጪያ ማሽኖች ናቸው።
*ይህ ከላይ የምታዩት Cold Planer ይባላል።
የአስፓልትን layer በፈለግነው ጥልቀት በመቁረጥ እላያቸው ላይ በተገጠመላቸው conveyor ወደ ጭነት መኪናዎች የሚጭኑ ለአስፓልት maintenance የምንጠቀምባቸው አስፓልት
መቁረጪያ ማሽኖች ናቸው።