👉Beam section
.
🚩Dimensions in millimeters
👍2
Design Step 1: depth from deflection( deformation) control

👉Since C30/37 concrete is used the limiting span to depth ratio from table 7.4 N Is 14 ( the beam is assumed to be highly stressed with ρ=1.5 %).

👉The limiting depth to prevent excessive deformation is:

👉d=le/14 ....where le is effective length of beam.

👉d=6000 mm/14=428.57 mm

Design step 2:- cover to reinforcement

👉Exposure class is assumed to be XC 1 and the value of Cmin,dur becomes 15 mm.

👉 for separate bar, the value of Cmin,b is equals to the diameter of bar( φ). Assuming φ=20 mm, and Cmin,b=20 mm.

➡️Cₘᵢₙ= max {Cₘᵢₙ,b ; Cₘᵢₙ,dᵤᵣ; 10 mm }

➡️Cₘᵢₙ=max{20 mm,15 mm, 10 mm}

➡️Cₘᵢₙ=20 mm

And the nominal cover becomes

➡️Cnom=Cmin+10=20+10=30 mm cover.

Design step 3:- overall depth

For stirrup assume 8 mm bars.

👉D=d+cover +φₛ+φₗ/2

👉D=428.57mm+30mm+8+20/2=476.57 mm

For ease of construction take D=500 mm ( nearest 50 ).

Design step 4:- Load calculation

Dead load
👉 self weight of beam
Unit weight of concrete(γ)= 25 KN/m³
Weight per meter:-
➡️γ*b*D
➡️25*0.25 *0.5=3.125 KN/m
👉 total dead load

Superimposed+self weight=10KN/m+3.125 KN/m=13.125 KN/M.

Design Load

Pd=1.35Gk+1.5Qk
Pd=1.35*13.125+1.5*8=29.72 KN/m.
.
@COTMp 👇
👍2
👉Beam model with
.
design load @COTMp 👇
Design step 5:-design strength of material

Concrete(fcd)

👉fcd=αcc*fck/γc

👉for C30/37 concrete fck is 30 Mpa.

👉αcc=0.85

👉γc=1.5

👉fcd=(0.85*30/1.5)=17 Mpa

Steel (fyd)

👉fyd=fyk/γs

👉γs=1.15

👉fyd=500/1.15=434.78 Mpa

Design step 6:- design moment calculation

👉 for simply supported beam the maximum moment occurs at mid span and it's vale is

➡️Mmax=Msd=Pd*L²/8

➡️Mmax=Msd=(29.72)*(6²)/8=133.73 KN-m

Design step 6:- check depth for flexure

👉effective depth of beam in order to be singly reinforced is calculated from

✓d=sqrt(Msd/(μsd*fcd*b))

✓Sqrt...[square root of ]
For zero percent redistribution of moment the limiting μsd is 0.295.

d=sqrt({133.73*10⁶}/{0.295*17*250})=326.59 mm

And the provided effective depth:

d= 500 - 30 - 8 - 20/2 = 452 mm

Since the provided depth is greater than calculated from flexure, depth is ok!

Design step 7:- Reinforcement calculation

Using design chart method

✓μsd={Msd*10⁶}/{fcd*b*d²)

✓μsd={133.73*10⁶}/{17*250*452²}=0.154 <0.295 ok!

from design chart the value of kz is

✓kz=0.92

and z( moment arm , the distance between Cc and Ts)

✓Z=kz*d=0.92*452=415.84 mm

Now the amount of reinforcement

✓As={Msd}/{Z*fyd}

✓As={133.73*10⁶}/{415.84*434.77}=739.65 mm²
.
@COTMp 👇
👍1
Design step 8:- check for minimum and maximum longitudinal reinforcement

Minimum reinforcement

✅As,min=0.26{fctm/fyk}bt*d. ( ES EN 1992-1-1:2015 equation 9.1 N)

✅From table 3.1 of ES EN 1992-1-1:2015 the value of fctm for C30/37 concrete is 2.9 Mpa.

👉As,min=0.26*{2.6/500}*250*452=152.776 mm²

👉As> As,min....provide As

Maximum reinforcement

ES EN 1992-1-1:2015 Article 9.2.1.1[3] " the cross sectional area of tension or compression reinforcement should not exceed 0.04Ac" and the national annex recommends the same value.

As,max=0.04*250*500=5000 mm²

As< As,max.....ok!

Design step 9:- calculate the number of bars

👉# of bars=As/as

Where
👉As calculated area of reinforcement

👉as is the area of one bar

👉as=(πφ²/4)=(π*20²/4)≈314 mm²

of bar=(739.65/314)=2.355≈3

🚩provide 3φ20 bars
.
@COTMp ... Finally 👇
👉 beam section detail

➡ All dimensions are in centimetres

➡ The two bars at the top are nominal reinforcement to hang the stirrups( the blue lines).
.
👏THANK YOU @COTMp
👆👆👆👆👆👆👆
👉ውድ የ @COTMp ቤተሰቦች ዛሬ ደሞ በጠየቃችሁን መሰረት ስለ ቢም ዲዛይን ማለትም ኣንድ የተሰራ ( Example Of Beam Design) ኣዘጋጅተናል።እናመሰግናለን።
.
⚡SHARE SHARE SHARE
👉ውድ የ @COTMp ተከታዮች ቻናላችን ቅድም Beam Design ኣይተናል ለ ነገ ሊቀርብላቹ እምትፈልጉትን Design ምረጡ።
👇👇👇👇👇
.
👍)Footing ✔)Shear
👉ይህ የምትመለከቱት ቤት በ ኣብዛኛው በ ትግራይ ክልል የ ገጠሪቱ ክፍል የሚገኝ ሲሆን "ህድሞ" በመባል ይታወቃል።
.
🚩የኋላው ከሌለ የለም የፊቱ✌
.
⚡ሼር በማድረግ @COTMP ያጋሩ።
Isolated Footing Design.pdf
704.7 KB
👉ትላንት በመረጣችሁት መሰረት Isolated Footing Design ኣዘጋጅተናል።
.
☑️ Isolated footing design to ES EN 1992-1-1:2015

👆The pdf Above shows isolated footing design using ES EN 1992-1-1:2015.

If you have any comment don't forget to leave it @COTMp
.
🚩In the document
.
👉Cx is the column dimension in x direction
👉Cy is the column dimension in y direction
Interior Planning Tips @COTMp
Interior Planning Tips @COTMp
Interior Planning Tips @COTMp
Interior Planning Tips @COTMp
Interior Planning Tips @COTMp
Interior Planning Tips @COTMp
Interior Planning Tips @COTMp
Interior Planning Tips @COTMp
Interior Planning Tips @COTMp
👆👆👆👆👆
👉ወድ የ @COTMp ቤተሰቦች ኣሁን ደሞ Interior Planning Tips ኣዘጋጅተናል። ለጓደኞችዎ እያጋሩ ይማማሩ።