As you know to determine weight of the bar we use two formulas
1. W= D² x Length of the bar
162
2. W = D² X length of the bar
52.9
When do we use the first formula when do we use the second formula ?
Share this question with your friends ?
@etconp
1. W= D² x Length of the bar
162
2. W = D² X length of the bar
52.9
When do we use the first formula when do we use the second formula ?
Share this question with your friends ?
@etconp
Telegram
Ethio Construction Engineering
🔨 World Construction Engineering
Latest updates, tips, and tutorials on building, civil engineering, and construction in World.
Learn, build, and grow with us!
📨 @Philemona7 Or @ETCONpBOT
For Ad:- https://telega.io/c/etconp
Latest updates, tips, and tutorials on building, civil engineering, and construction in World.
Learn, build, and grow with us!
📨 @Philemona7 Or @ETCONpBOT
For Ad:- https://telega.io/c/etconp
Forwarded from Ethio Construction Engineering (जॉर्डनो ג׳ורדנו ጆርዳኖ جوردانو จอร์แดโน่ JORDANO Ιορδάνοςஜார்டானோ)
Archicad manual @ETCONP.pdf
20.2 MB
ACHICAD MANUAL
Contents
👉🏿Introduction
👉🏿concepts and tools
👉🏿 project and office setup
👉🏿creating a virtual building
👉🏿visualization
👉🏿 project information
👉🏿Document Layout
👉🏿 project management and coordination
#archicad #virtual #3D
@etconp
Contents
👉🏿Introduction
👉🏿concepts and tools
👉🏿 project and office setup
👉🏿creating a virtual building
👉🏿visualization
👉🏿 project information
👉🏿Document Layout
👉🏿 project management and coordination
#archicad #virtual #3D
@etconp
Archicad manual @ETCONP.pdf
20.2 MB
ACHICAD MANUAL
Contents
👉🏿Introduction
👉🏿concepts and tools
👉🏿 project and office setup
👉🏿creating a virtual building
👉🏿visualization
👉🏿 project information
👉🏿Document Layout
👉🏿 project management and coordination
#archicad #virtual #3D
@etconp
Contents
👉🏿Introduction
👉🏿concepts and tools
👉🏿 project and office setup
👉🏿creating a virtual building
👉🏿visualization
👉🏿 project information
👉🏿Document Layout
👉🏿 project management and coordination
#archicad #virtual #3D
@etconp
@etconp crack.zip
41.4 MB
ARCHICAD CRACK
ይህን crack copy አርጋችሁ local disc ጋር ሄዳችሁ archicad የሚል file ላይ paste ስትሉ replace ይላል yes ብላችው ውጡ።
Copy this crack file and go to local disc and open program file and search for archicad then paste on archicad file then replace it .
ይህ crack XF patch አይደለም።
This crack file is not XF patch file.
Turn off your internet while installing
Internet መጥፋቱን ያረጋግጡ
@etconp
ይህን crack copy አርጋችሁ local disc ጋር ሄዳችሁ archicad የሚል file ላይ paste ስትሉ replace ይላል yes ብላችው ውጡ።
Copy this crack file and go to local disc and open program file and search for archicad then paste on archicad file then replace it .
ይህ crack XF patch አይደለም።
This crack file is not XF patch file.
Turn off your internet while installing
Internet መጥፋቱን ያረጋግጡ
@etconp
@etconp ARCHICAD-20-Update-5011-1.0.exe
576.5 MB
ARCHICAD UPDATE PATCH
አብዛኞቻችሁ በጠየቃችሁን መሰረት የ Archicad setup ይዘንላችሁ መተናል
Instructions /መመሪያ
👉🏿Make sure to turn off your internet while installing
👉🏿ይህን software በምትጭኑበት ጊዜ internet አጦፉ።
How to install / እንዴት ነው የሚጫነው?
1. Install the setup / setup’ው በቅድሚያም ይጫኑ launch ሳይሉ ይተውት
Don’t launch it leave it
2. Install update patch / በመቀጠል update patch’ሁን ይጫኑት
3. Program file ውስጥ ሄደው Archid file ላይ crack file’ሁን copy pate ከዛን repalce በሉት/ fo to local disc and you will get archicad file copy the crack file and paste on the program file ( replace it )
Turn off your internet while installing
The crack is not XF patch file
Crack’ሁ XF patch file አይደለም
ፋይሉ 0.5 GB ስለሆነ WiFi ቢጠቀሙ ይመረጣል
@etconp
አብዛኞቻችሁ በጠየቃችሁን መሰረት የ Archicad setup ይዘንላችሁ መተናል
Instructions /መመሪያ
👉🏿Make sure to turn off your internet while installing
👉🏿ይህን software በምትጭኑበት ጊዜ internet አጦፉ።
How to install / እንዴት ነው የሚጫነው?
1. Install the setup / setup’ው በቅድሚያም ይጫኑ launch ሳይሉ ይተውት
Don’t launch it leave it
2. Install update patch / በመቀጠል update patch’ሁን ይጫኑት
3. Program file ውስጥ ሄደው Archid file ላይ crack file’ሁን copy pate ከዛን repalce በሉት/ fo to local disc and you will get archicad file copy the crack file and paste on the program file ( replace it )
Turn off your internet while installing
The crack is not XF patch file
Crack’ሁ XF patch file አይደለም
ፋይሉ 0.5 GB ስለሆነ WiFi ቢጠቀሙ ይመረጣል
@etconp
@etconp ARCHICAD-20-INT-3012-1.3.exe
1.4 GB
ARCHICAD setup
አብዛኞቻችሁ በጠየቃችሁን መሰረት የ Archicad setup ይዘንላችሁ መተናል
Instructions
👉🏿Make sure to turn off your internet while installing
👉🏿ይህን software በምትጭኑበት ጊዜ internet አጦፉ።
How to install / እንዴት ነው የሚጫነው?
1. Install the setup / setup’ው በቅድሚያም ይጫኑ launch ሳይሉ ይተውት
Don’t launch it leave it
2. Install update patch / በመቀጠል update patch’ሁን ይጫኑት
3. Program file ውስጥ ሄደው Archid file ላይ crack file’ሁን copy pate ከዛን repalce በሉት/ fo to local disc and you will get archicad file copy the crack file and paste on the program file ( replace it )
Turn off your internet while installing
The crack is not XF patch file
Crack’ሁ XF patch file አይደለም
ፋይሉ 1.4GB ስለሆነ WiFi ቢጠቀሙ ይመረጣል
@etconp
አብዛኞቻችሁ በጠየቃችሁን መሰረት የ Archicad setup ይዘንላችሁ መተናል
Instructions
👉🏿Make sure to turn off your internet while installing
👉🏿ይህን software በምትጭኑበት ጊዜ internet አጦፉ።
How to install / እንዴት ነው የሚጫነው?
1. Install the setup / setup’ው በቅድሚያም ይጫኑ launch ሳይሉ ይተውት
Don’t launch it leave it
2. Install update patch / በመቀጠል update patch’ሁን ይጫኑት
3. Program file ውስጥ ሄደው Archid file ላይ crack file’ሁን copy pate ከዛን repalce በሉት/ fo to local disc and you will get archicad file copy the crack file and paste on the program file ( replace it )
Turn off your internet while installing
The crack is not XF patch file
Crack’ሁ XF patch file አይደለም
ፋይሉ 1.4GB ስለሆነ WiFi ቢጠቀሙ ይመረጣል
@etconp
👍5
#beam
Find the number of bar and the spacing
➪ As(area of steel)
= 0.00503m² or 5032.248mm²
➪ Length of the bar
= 300 cm or 3m
➪ #22 bar ( diameter = 22.225mm)
➪ concrete cover = 5cm or 50mm
@etconp
Facebook:- https://www.facebook.com/etconp/
Find the number of bar and the spacing
➪ As(area of steel)
= 0.00503m² or 5032.248mm²
➪ Length of the bar
= 300 cm or 3m
➪ #22 bar ( diameter = 22.225mm)
➪ concrete cover = 5cm or 50mm
@etconp
Facebook:- https://www.facebook.com/etconp/
👍1
The maximum shear stress is equal to _______ of morh’s circle ⭕️
Anonymous Quiz
18%
Area
20%
Diameter
23%
Circumference
39%
Radius
Find the side of square column footing
Given information
Load (P) = 2000 kN
Column size = 400 mm x 400 mm
Soil Bearing Capacity = 150 kN/m2
*Footing area for the column
Take 10% of the load P
@etconp
Facebook:- https://www.Facebook.com/etconp/
Given information
Load (P) = 2000 kN
Column size = 400 mm x 400 mm
Soil Bearing Capacity = 150 kN/m2
*Footing area for the column
Take 10% of the load P
@etconp
Facebook:- https://www.Facebook.com/etconp/
#soilmechanics #soil
Given 1870g (gram) of wet compacted soil into mold with volume of 1000cm³. The soil is put into oven and dried to a constant weight of 1667 gram. The specific gravity of the soil is assumed to be 2.56.
Calculate
A. Water content (Ww)
B. Dry unit weight (γdry)
C. Porosity of the soil (n)
D. Degree of saturation (S)
E. Saturated unit weight of the soil (γsaturated)
@etconp
Facebook:- https://www.Facebook.com/etconp/
Given 1870g (gram) of wet compacted soil into mold with volume of 1000cm³. The soil is put into oven and dried to a constant weight of 1667 gram. The specific gravity of the soil is assumed to be 2.56.
Calculate
A. Water content (Ww)
B. Dry unit weight (γdry)
C. Porosity of the soil (n)
D. Degree of saturation (S)
E. Saturated unit weight of the soil (γsaturated)
@etconp
Facebook:- https://www.Facebook.com/etconp/
#soil mechanics #soil
The moist unit weight of a soil is 16.5KN/m³. Given water content of soil is 15% and specific gravity (Gs) = 2.7 based on the given information find
A. Dry unit weight( γdry)
B. The porosity (n)
C. The degree of saturation (S), and
D. The mass of water in kg/m³ that must
be reach full saturation
@etconp
Facebook:- https://www.Facebook.com/etconp/
The moist unit weight of a soil is 16.5KN/m³. Given water content of soil is 15% and specific gravity (Gs) = 2.7 based on the given information find
A. Dry unit weight( γdry)
B. The porosity (n)
C. The degree of saturation (S), and
D. The mass of water in kg/m³ that must
be reach full saturation
@etconp
Facebook:- https://www.Facebook.com/etconp/
What’s the weight 16mm diameter and 12m long bar ?
@etconp
Facebook:- https://www.Facebook.com/etconp/
@etconp
Facebook:- https://www.Facebook.com/etconp/
Ethio Construction Engineering
#soil mechanics #soil The moist unit weight of a soil is 16.5KN/m³. Given water content of soil is 15% and specific gravity (Gs) = 2.7 based on the given information find A. Dry unit weight( γdry) B. The porosity (n) C. The degree of saturation (S), and…
#soilmechanics
Question and answer
Soil mechanics
@etconp
Facebook:- https://www.Facebook.com/etconp/
Question and answer
Soil mechanics
@etconp
Facebook:- https://www.Facebook.com/etconp/
The most stable cement for under water construction 🚧
Anonymous Quiz
30%
Rapid hardening cement
20%
OPC
18%
PPC
32%
Quick setting cement
Ethio Construction Engineering
The most stable cement for under water construction 🚧
What’s the difference between rapid setting cement and quick setting cement?
@etconp
Facebook:- https://www.Facebook.com/etconp/
@etconp
Facebook:- https://www.Facebook.com/etconp/
👍1
Ethio Construction Engineering
What’s the difference between rapid setting cement and quick setting cement? @etconp Facebook:- https://www.Facebook.com/etconp/
Answer
The difference between the quick setting cement and rapid hardening cement is that quick–setting cement sets earlier. At the same time, the rate of gain of strength is similar to Ordinary Portland Cement, while quick hardening cement gains strength quickly. Formworks in both cases can be removed earlier. The construction which is done by using Ordinary Portland cement generally takes 24 hours to set and hardened completely and it requires consistent curing. The OPC cement shuttering removal time is about 14 days.
In some special cases, it is not possible to keep shuttering for 14 days. Some construction required to be completed very fast. For example, Construction of roads and underwater construction, in this case Extra Rapid Hardening cement is used which will set and hardened quickly.
@etconp
Facebook:- https://www.Facebook.com/etconp/
The difference between the quick setting cement and rapid hardening cement is that quick–setting cement sets earlier. At the same time, the rate of gain of strength is similar to Ordinary Portland Cement, while quick hardening cement gains strength quickly. Formworks in both cases can be removed earlier. The construction which is done by using Ordinary Portland cement generally takes 24 hours to set and hardened completely and it requires consistent curing. The OPC cement shuttering removal time is about 14 days.
In some special cases, it is not possible to keep shuttering for 14 days. Some construction required to be completed very fast. For example, Construction of roads and underwater construction, in this case Extra Rapid Hardening cement is used which will set and hardened quickly.
@etconp
Facebook:- https://www.Facebook.com/etconp/
Telegram
Ethio Construction Engineering
🔨 World Construction Engineering
Latest updates, tips, and tutorials on building, civil engineering, and construction in World.
Learn, build, and grow with us!
📨 @Philemona7 Or @ETCONpBOT
For Ad:- https://telega.io/c/etconp
Latest updates, tips, and tutorials on building, civil engineering, and construction in World.
Learn, build, and grow with us!
📨 @Philemona7 Or @ETCONpBOT
For Ad:- https://telega.io/c/etconp