๐Ÿ‘‰TYPES OF STAIRS: @COTMp
.
โ–ถDepending upon the various arrangement of steps, stairs can be classified under following categories:
1. STRAIGHT STAIR:
In this stair, all the steps are arranged continuously
along in one direction. One flight may be split into
one or more than one flight by interposing a
landing. This stair can be used where narrow and
long space is available for a staircase such as
entrance, porch etc.
2. DOGGED-LEGGED STAIR:
This stair consists of two straight flights of steps
with direct turns between them. This stair is very
useful where the total width of the stair is just twice
the width of the steps.
3. OPEN NEWEL STAIR:
This type of stair consists of two or more flights
arranging a well or opening between the backward
and forward flights. When all the steps are difficult
to arrange in two flights, a short third flight of 3 to
6 steps may be provided along the direction
perpendicular to the hall. Open newel stair is mostly
adopted in the lift.
4. GEOMETRICAL STAIR:
This is another type of open newel stair where the
open well between the forward and the backward
flight is curved. This stair may contain different
geometrical shape. Here the change in direction is
achieved by using winders.
5. CIRCULAR STAIR:
In this type of stair, all the steps radiate from a
newel or well hole, in the form of winders. The
circular stair is adopted at the back side of a
building to access its various floors.
6. SPIRAL STAIR:
Spiral stair is very similar to a circular stair. It
consists of individual steps or treads, connecting to
a centre column. The overall diameter of the stair
may range from 1 to 2.5 m.
7. QUARTER-TURN STAIR:
The quarter-turn stair can be defined as the stairs
that are turned at 90 degrees with the help of level
landing.
8. BIFURCATED STAIR:
This type of stair is provided in modern public
buildings as well as residential buildings. In this
stair, the flight is so arranged that there is a wide
flight at the start which is sub-divided into narrow
flights at the mid-landing. The narrow flights start
from either side of the mid landing.
.
๐ŸšฉJoin for more Discussion @COTMA
๐Ÿ‘‡๐Ÿ‘‡๐Ÿ‘‡๐Ÿ‘‡๐Ÿ‘‡๐Ÿ‘‡
@COTMA @COTMA @COTMA
๐Ÿ‘‰SLUMP TEST OF CONCRETE @COTMp
~~~~~~~~~~~~~~~~
โ–ถThe concrete slump test is an empirical test that
measures the workability of fresh concrete. The test
is performed to check the consistency of freshly
mixed concrete in a specific batch. *Consistency refers to the ease and homogeneity with which the concrete can be mixed, placed, compacted and finished. *This test is most widely used due to the simplicity of apparatus and simple test procedure.
*The slump test gives satisfactory results for the
concrete mix of medium to high workability and
unfortunately, it does not give the correct indication
of low workability, which may give zero slumps.
This test is also known as slump cone test.
โ–ถAPPARATUS FOR CONCRETE SLUMP TEST:
1. Mould or slump cone with a height of 300 mm,
bottom diameter 200 mm, and top diameter 100
mm.
2. Standard tamping rod.
3. Non-porous base plate.
4. Measuring scale.
โ–ถPROCEDURE OF TEST:
1. First, clean the inner surface of the empty mould and then apply oil to it.
2. Set the mould on a horizontal non-porous and
non-absorbent base plate.
3. Fill the mould fully by pouring freshly mixed
concrete in three equal layers.
4. Stroke each layer 25 times with the standard
tamping rod over the cross section.
5. After stroking 25 times the top layer is struck off
level, now lift the mould slowly in the vertical
direction without disturbing the concrete cone.
6. Use the measuring scale to measure the difference level between the height of the mould and the concrete sample.
*The subsidence of concrete is known as the slump and the value of slump is measured in mm.
โ–ถTYPES OF SLUMP:
*True Slump: The concrete mass after the test when
slumps evenly all around without disintegration is
called the true slump.
*Shear Slump: When one-half of the concrete mass
slide down the other is called the shear slump. This type of slump is obtained in a lean concrete mix.
*Collapse Slump: When the sample is collapsed due to adding excessive water, it is known as collapse slump.
*Zero Slump: For very stiff or dry mixes it does not
show any changes of the slump after removing the
slump cone.
โ–ถADVANTAGES OF CONCRETE SLUMP TEST:
1. The procedure of slump test is simple and easy
than any other workability test.
2. Inexpensive and portable apparatus are required
for this test.
3. Slump test can be performed at the construction site as well as in the laboratory.
โ–ถLIMITATIONS OF CONCRETE SLUMP TEST:
1. The slump test is limited to concretes with the
maximum size of aggregate less than 38 mm.
2. The test is suitable only for concretes of medium
or high workabilities (i.e having slump values of 25
mm to 125 mm).
3. For very stiff mixes having zero slumps, the
slump test does not show any difference in concretes of different workabilities.
*Recommended Values Of Slumps For Different
Concrete Mixes:
โ–ถTypes Of Concrete Slump Range In mm
1. Heavy mass construction 25-50
2. Pavements 20-30
3. Bridge deck 25-75
4. Beams and slabs 50-100
5. Columns, retaining
walls and thin vertical members etc. 75-150
6. Vibrated concrete 12-25
.
๐Ÿšฉแˆผแˆญ แ‰ แˆ›แˆญแŒ แˆˆแˆแˆ‰แˆ แŠฅแŠ“แ‹ณแˆญแˆตแข
๐Ÿ‘‰OPC VS PPC cement @COTMp
.
โ–ถPPC: PPC or Portland Pozzolan's Cement is a mixture of Pozzolan's panic material with Argillaceous and Calcareous materials in powdered form. *Pozzolan's increases the strength of the cement but initial setting time is more than OPC.
*Pozzolan's should be in the range of 10โ€“30%. If more than this range
then strength will be reduced.
*It is useful for most
Civil construction works like mass concreting etc. It
is economical for projects as less cost of cement
than OPC. Gypsum is used for controlling of setting
time.
โ–ถADVANTAGES OF PPC:
1. Higher durability of concrete structure due to less permeability of water.
2. More resistance towards the attack of alkalies,
sulfates, chlorides, chemicals.
3. Better workability.
4. Low heat of hydration.
5. Due to high fineness, PPC has better cohesion
with aggregates and makes more dense
concreteness.
6. Comparative lower Water-Cement ratio provides an added advantage for the further increase of compressive strength of the concrete.
7. Better surface finish.
.
โžกOPC: OPC or Ordinary Portland Cement is a mixture of Calcareous materials with Argillaceous material in
proportional ratio. Gypsum is used for controlling
the setting time. It has less setting time than PPC.
It is useful where work to be complete soon. It is
costlier than PPC. It is available in various grades
such 33, 43 & 53. OPC grade 43 is very useful
nowadays.
โ–ถADVANTAGES OF OPC:
1. Produces highly durable and sound concrete due
to very low percentage of alkalis, chlorides,
magnesia and free lime in its composition.
2. Almost negligible chloride content results in
restraining corrosion of concrete structure in hostile environments.
3. Significant saving in cement consumption while
making concrete of grades M15, M20, M25, M35
and pre-cast segments due to high strength.
โ–ถDIFFERENCE BETWEEN OPC AND PPC:
โžกORDINARY PORTLAND CEMENT (OPC):
1. OPC is produced simply by grinding limestone
and secondary materials to a powder.
*The main raw materials used for manufacturing OPC is calcareous material, argillaceous material, and gypsum.
2. The durability of OPC is lower than PPC.
3. The setting time is of OPC is less than PPC.
4. Costlier than PPC.
5. Mostly used where fast construction is required.
6. The different grades of OPC are:
*OPC 33 Grade
*OPC 43 Grade
*OPC 53 Grade
.
โ–ถPOZZOLANIC PORTLAND CEMENT (PPC):
1. PPC is a variation of OPC which includes a
mixture of a pozzolanic material which is known to
increase the strength of concrete. The raw materials used for manufacturing of PPC is OPC, gypsum, pozzolanic materials such as fly ash, rice husk ash, volcanic tuffs and pumicites, clay & shale, etc.
2. Mostly used in mass concreting, plaster and
masonry.
3. Durability is high.
4. Setting time is greater than OPC.
5. Curing period is a little higher than OPC.
6. It can be used in all type of construction work.
7. There are no such specific grades of PPC like
OPC.
8. Low cost.
.
๐Ÿ‘‡๐Ÿ‘‡๐Ÿ‘‡๐Ÿ‘‡๐Ÿ‘‡
Join for more updates via the link below;
t.me/COTMp
๐Ÿ‘†๐Ÿ‘†๐Ÿ‘†๐Ÿ‘†๐Ÿ‘†
โšก แŠ แˆแŠ‘แŠ‘ Join แ‰ แˆ›แˆจแŒ แŠฅแŠ“ แˆˆแŒ“แ‹ฐแŠ›แ‹Ž แŠฅแŠ“ แˆˆแˆšแ‹ซแ‰แ‰ต แˆแˆ‰ แˆผแˆญ แ‹ซแ‹ตแˆญแŒ‰แข
๐Ÿ‘‰BASICS OF CRACKING PROBLEMS: @COTMp
.
โ–ถThe subject โ€œ CRACKS โ€œ or โ€œ CRACKING โ€œ in
concrete is indeed much debated. However, there is
inadequate clarity as to the reason for cracking and
what mey be done to limit its occurrence or
eliminate it altogether.
The phenomenon of the appearance of cracks in
concrete is often a subject that raises several
questions. Either at the initial stage or with time,
cracks may appear in a concrete structure. It should
first of all be accepted that cracks of some type or
other are inevitable in any concrete. They can be
minimized to a large extent by proper practices.
Cracks may be big or small, structural or non-
structural. All of them can be a nuisance by way of
either marring the appearance or function as a
passage for atmospheric polluting gases and
moisture to either the body of concrete and causes
distress.
Cracks in the concrete structure do not always
mean that the structure is not useable. As cracking
of concrete is inherent, what really matters is the
type of structure and the nature of cracking. Cracks
that are acceptable for building structures may not
be acceptable for water relating structures.
Considering that cracking xan never be completely
eliminated, it is necessary to be aware of the
causes, evaluation and the methods of repair
whoever required.
CRACKS
Cracks are generally of towtypes : Structural and
non-structural. Cracks can occur in hardened or
unhardened concrete.
STRUCTURAL CRACKS
It is fundamental that hardened reinforced concrete
cracks in the tensile zone when subjected to
externally imposed structural loads. By means of
appropriate design and detailing technique, these
cracks can be limited to acceptable levels in terms
of structural integrity and aesthetics.
NON_STRUCTURAL CRACKS
Concrete is also liable to crack in both the plastic
and hardened states due to the nature of its
constituent materials. These intrinsic cracks are as
inevitable as structural cracks. Ti is often possible
to predict when intrinsic cracks are likely and to
limit them to acceptable levels by means of good
design and/or proper construction techniques.
DORMANT AND LIVE CRACKS:
Cracks caused by shrinkage, temperature gradient
due to hydration and alkali silica reaction ( ASR )
are less dangerous the cracks caused by thermal
expansion and loads. This is because shrinkage
and hydration temperature gradient result in
dormant cracks ( where the width does not vary
with time) and other mechanisms result in live
cracks (where the width increases with time
Dormant cracks, especially narrow ones, are more
likely to undergo autogenous healing and
realkalisation. The crack may heal owing to
following conditions:
โ€ข carbon dioxide diffusing into the crack leading to
carbonation of the calcium hydroxide and
precipitation of calcium carbonate.
โ€ข Cement hydration due to presence of moisture.
โ€ข Hydration diffusing from the bulk concrete into the
heaked zone thereby increasing the pH in that area.
Live cracks are more likely than domant ones. They
result in collection of debris at the base owing to
movement of the sides on the cracks. This can
impede temporarily the passage of depassivating
substances to the reinforcements. However,
autodeneous healing is unlikely with live cracks.
CAUSES OF CRACKING:
Cracking will occur whenever the applied strain
exceeds the tensile strain capacity of the concrete.
The tensile strain capacity of concrete varies with
age and with
Age at which cracks may occur.
Cracks can appear at any time. The age which
some typical can occur are given in the Table.
TABLE โ€“ AGE AT WHICH CRACKS MAY APPEAR:
Sr. no. types of cracks Age
1. plastic shrinkage First few minutes or hours after
concreting .
2. plastic settlement First few minutes or hours
after concreting.
3. due to corrosion After one year or many years.
4. due to loads After loads are imposed and the
time duration of loading
5. due to weight Just after formwork support are
removed.๐Ÿ‘‡๐Ÿ‘‡๐Ÿ‘‡
6. due to chemical changes in hardened
concrete After one or many years depending in
chemical attack from outside (sulphate ) Or
chemical reaction from within (ASR)
.
โ–ถCRITICAL CRACK WIDTH: The most common reasons for controlling crack
width are following:
APPERANCE : Unsightly cracking should be avoid
since it may cause concern to the occupants of the external structure.
Ti may also contribute to
unsightly staining on exposed external surfaces,
where salts and rust are washed out from the crack.
DURABILITY: Excessively wide cracks may lead to
corrosion of the reinforcement which in turn may lead to spalling of concrete due to the expansive nature of the corrosion process.
WATER-TIGHTNESS: This is of importance in water
retaining structures.
In particular instances there may be other reasons for controlling cracking in addition to the three reasons cited above.
Crack width is, generally, to be taken to mean the
measurable width of a crack at the surface of
concrete. Crack width limitation is important from durability considerations. Most structural codes
prescribe maximum allowed crack widths.
Codes normally consider cracking caused by
external imposed conditions such as live loading
and provide formula for calculating the crack width
in the design phase. Mainly bending and tension or
bending and axial load are considered. The
direction of such cracks is perpendicular to the
direction of the main reinforcement. Plastic
shrinkage cracks follow the line of reinforcement.
According to IS: 456-2000 the surface of the width
of the cracks should not in general exceeds o.3 mm
in members where cracking is not harmful and does
not have any serious effect either on the
preservation of reinforceing steel or on the durability
of the structures.
In members, where cracking of the tensile zone is
harmful either because they are moisture or in
contact with soil or groundwater, an upper limlt of
0.2 mm is suggested.
For aggressive conditions the surface width of
cracks should not generally exceed 0.1 mm. The
crack width conditions the surface width of cracks
should not be generally exceed 0.1 mm. The crack
width is measured at the surface for the above
purposes. However some other codes specify the
width at points near the reinforcement.
.
๐ŸšฉShare Share Share
๐Ÿ‘‰TYPES OF STAIRS: @COTMp
.
โ–ถDepending upon the various arrangement of steps, stairs can be classified under following categories:
1. STRAIGHT STAIR:
In this stair, all the steps are arranged continuously
along in one direction. One flight may be split into
one or more than one flight by interposing a
landing. This stair can be used where narrow and
long space is available for a staircase such as
entrance, porch etc.
2. DOGGED-LEGGED STAIR:
This stair consists of two straight flights of steps
with direct turns between them. This stair is very
useful where the total width of the stair is just twice
the width of the steps.
3. OPEN NEWEL STAIR:
This type of stair consists of two or more flights
arranging a well or opening between the backward
and forward flights. When all the steps are difficult
to arrange in two flights, a short third flight of 3 to
6 steps may be provided along the direction
perpendicular to the hall. Open newel stair is mostly
adopted in the lift.
4. GEOMETRICAL STAIR:
This is another type of open newel stair where the
open well between the forward and the backward
flight is curved. This stair may contain different
geometrical shape. Here the change in direction is
achieved by using winders.
5. CIRCULAR STAIR:
In this type of stair, all the steps radiate from a
newel or well hole, in the form of winders. The
circular stair is adopted at the back side of a
building to access its various floors.
6. SPIRAL STAIR:
Spiral stair is very similar to a circular stair. It
consists of individual steps or treads, connecting to
a centre column. The overall diameter of the stair
may range from 1 to 2.5 m.
7. QUARTER-TURN STAIR:
The quarter-turn stair can be defined as the stairs
that are turned at 90 degrees with the help of level
landing.
8. BIFURCATED STAIR:
This type of stair is provided in modern public
buildings as well as residential buildings. In this
stair, the flight is so arranged that there is a wide
flight at the start which is sub-divided into narrow
flights at the mid-landing. The narrow flights start
from either side of the mid landing.
.
๐ŸšฉGo for Conversation
๐Ÿ‘‡๐Ÿ‘‡๐Ÿ‘‡๐Ÿ‘‡๐Ÿ‘‡
@COTMA
๐Ÿ‘‰TOP 8 TYPES OF ESTIMATE IN CONSTRUCTION WORKS @COTMp
.
โ–ถVarious types of estimates as prepared
are of following types:-
1. Approximate or Preliminary Estimate
The estimate is prepared to know the approximate cost of the work and to take the administrative approval by the competent authority of the department for which the work is to be executed this
estimate is also called as *ROUGH COST ESTIMATE. The cost of building, cost of land, cost of roads etc. are shown separately in this estimate.
The necessity and urgency of the estimate and rates
arrived at for knowing the cost are fully explained in this estimate.
The specifications to be adopted are also fully explained. The rates provided in the estimate and for unit basis i.e., per sq.m for buildings, per km length of road or canal and per running meter of span for culverts and bridges.
2. Plinth Area Estimate
The estimate prepared on the plinth area basis of the building by using suitable
plinth area rates is called the plinth area estimate. The area of the building at the plinth level, by taking the external dimensions is worked out and is multiplied by suitable rate per sq m. The cost thus arrived at is the cost of
building based on plinth area. The plinth area rates for different types of buildings are different i.e., the rates for residential
buildings are less than the rates for the hospital buildings etc. Plinth area
estimate is also a rough cost estimate.
3. Cubical Content Estimate This estimate is also an approximate and
is prepared on the basis of cubical contents of the building. The cost of the
building is calculated by multiplying the plinth area by the height of building and cubical content rate i.e., plinth area multiplied by; height multiplied by;
cubical content rate. The plinth area is calculated as staved above and the
height is taken from the top of flat roof (or halfway of the sloped roof) to the top of concrete in foundation. The cubical
content rate is deduced from the cost of similar building in the locality. The
parapet is not taken in the calculations.
*This estimate is more accurate than the
plinth area estimate.
4. Detailed Estimate
After obtaining the administrative
approval of the concerned department against the rough cost estimate.
As this estimate is based on the plans and sections of the building so
it is the most accurate estimate. The quantities of items under various sub
heads of work are calculated from the drawings and cost of each item is worked out separately according to the prevalent market rates and is totaled. After doing the total of all items
a percentage of 3 to 5 is added for unforeseen items, change of design and provision of petty-establishment. Grand
total so obtained gives the estimated cost of building. This estimate is then
submitted to the competent authority for
according technical sanction.
The detailed estimate is accompanied by report,
design and scope, detailed drawings, detailed specifications, justification of the rates provided and the limit for execution
of the work. The work us executed according to the detailed estimate.
5. Revised Estimate
When the cost of the estimate exceeds
or likely to increase by 10% or more, a revised estimate is required to be
prepared.
It is accompanied by the
comparative statement showing the variations of each item of work and
giving the reasons of excess.
6. Supplementary Estimate
When some addition to the original work is made a fresh detailed estimate for the additional work is prepared to supplement the original estimate
7. Annual Repair of Annual Maintenance Estimate This estimate is prepared to carry out annual repairs or maintenance.
8. Extension and Improvement Estimate
When some changes and extensions are required to be made in the old work, the cost of which cannot be met by the annual repair/maintenance estimate, a detailed estimate is prepared for such work which is called as Extension and Improvement estimate.
.
๐Ÿšฉแˆผแˆญ แ‰ แˆ›แ‹ตแˆจแŒ แˆˆแ‹ˆแ‹ณแŒ…แ‹Ž แ‹ซแŒ‹แˆฉแข แŠฅแŠ“แˆ˜แˆฐแŒแŠ“แˆˆแŠ•แข
๐Ÿ‘‰PROPERTIES OF HARDENED CONCRETE @COTMp
.
โ–ถThe following are the properties of concrete
in its hardened state, used by the designer
during design process of reinforced concrete structure.
1. COMPRESSIVE STRENGTH
The characteristics strength is defined as
the strength of concrete below which not
more than 5% of the test results are expected to fall. As per IS: 456 concrete
mix always designed for the target strength
computed as,*Target strength: Characteristics strength + (1.65 x standard deviation) C-20 is the minimum grade of concrete for
use in RCC work.
2. TENSILE STRENGTH
Flexural strength is one measure of the
Tensile strength of concrete. In concrete
structure one set of visible cracks occur under flexure to compute load factor
against cracking .
According to IS: 456 the
tensile strength of concrete can be
computed from the compressive strength
using empirical relation given by:
Flexural strength: f =0.7โˆšfck N/mm
3. MODULUS ELASTICITY
Modulus of elasticity of concrete which is
significantly influenced by the following
factors.
*Type of the aggregates used
*Type of cement and
*Mix proportions
***This property is required for the computations of deflections of strutural
concrete members which forms an
important limit state in the design of concrete members. In the absence of test data, the modulus of elasticity of concrete
is normally related to the compressive strength and is computed by the empirical relation recommended by IS: 456-2000 code and is expressed as,
E =5000โˆšfck
Where E is the short term static modulus
of elasticity of concrete expressed in N/
mm
f is the characteristic compressive
strength of concrete expressed in N/mm .
4. SHRINKAGE OF CONCRETE
The ingredients of concrete and
environmental conditions like temperature
and humidity influence the total shrinkage
of concrete. Water content in concrete
significantly affects the shrinkage. The IS:
456-2000 recommends the total shrinkage
strain as 0.0003 in the absence of test
data. Drying shrinkage in plain concrete
may result in surface cracks. Shrinkage of
concrete also influences the deflections of
reinforced concrete members.
5. CREEP OF CONCRETE
The inelastic time dependent strain
developed in a concrete emeber under
sustained loading is refered to as creep of
concrete. Creep of concrete is influenced
by following factors.
Cement content,
W/C ratio,
Temperature and humidity,
Size of structural element,
Type of loading and period of loading.
In the absence of reliable experimental
data, the creep coefficient is expressed as
the ratio of ultimate creep strain/elastic
strain at various ages of loading as
recommended by IS: 456-2000 are given
below.
Age at Loading Creep Coefficient
7 days 2.2
28 days 1.6
1 year 1.1
Creep of concrete significantly affects the
deflections of reinforced concrete flexural
members. Higher creep coefficient results
in large deflections. The value of creep
coefficient is useful in the computation of
time dependent deflections in reinforced
concrete members.
6. COEFFICIENT OF THERMAL
EXPANSION
The coefficient of thermal expansion of
concrete, influenced mainly by the type of
aggregate used in concrete is required for
the design of structures like chimneys,
water tanks, silos etc.
.
๐ŸšฉSHARE SHARE SHARE
๐Ÿ‘‰แ‹›แˆฌ แ‹ฐแˆž แˆตแˆˆ Load Combination แ‰  แŠฃแ‹ฒแˆฑ แ‹จ EBCS แŠฎแ‹ต แŠฃแ‰ฅแˆจแŠ• แŠฅแŠ•แ‹ญ @COTMp
.
Combo 1= DL + LL
Combo 2= 1.35DL + 1.5LL
Combo 3= DL + 0.3LL + EQx
Combo 4= DL + 0.3LL - EQx
Combo 5= DL + 0.3LL + EQy
Combo 6= DL + 0.3LL - EQy
Combo 7= max( Combo 2 up to 6)
.
.
แˆแˆŒ แŒแŠ• แŠขแˆ„ แАแ‹ แˆ›แˆˆแ‰ต แŠ แ‹ญแ‹ฐแˆˆแˆแกแก แˆˆแˆแˆณแˆŒ 0.3LL แ‹จแˆšแˆˆแ‹
แˆ…แŠ•แƒแ‹แŠ• แ‹จแˆแŠ•แŒ แ‰€แˆ˜แ‹ แˆˆDomestic/residential purpose
แŠจแˆ†แА แАแ‹แกแก Shop แŠจแˆ†แА 0.6LL storage แŠจแˆ†แА แ‹ฐแˆž 0.8LL
แ‹ญแˆ†แŠ“แˆแกแก แŠจแ‹šแˆ…แˆ แ‰ แ‰ฐแŒจแˆ›แˆช แˆแˆ‰แˆ แŽแˆญแˆ™แˆ‹ แˆ‹แ‹ญ แ‹จแ‰ฐแˆˆแ‹ซแ‹ฉ
แŠฎแŠ•แ‹ฒแˆฝแŠ–แ‰ฝ แˆตแˆ‹แˆ‰ แŠฅแАแˆฑแŠ• แˆ›แ‹จแ‰ต แ‹ซแˆตแˆแˆแŒ‹แˆแกแก แˆ˜แŒˆแŠ›แ‰ธแ‹แˆ EBCS
EN 1990: 2014 แŠจ Equation 6.9 แŠฅแˆตแŠจ 6.16 แАแ‹แกแก

แŽแˆญแˆ™แˆ‹แ‹Žแ‰น แ‹แˆตแŒฅ แ‹จแˆšแŒˆแ‰กแ‰ตแŠ• variable แˆˆแˆ›แŒแŠ˜แ‰ต แ‹ฐแˆž
check the Annex part แŠฅแ‹ฉแ‰ตแข
.
combination แˆฐแ‰ฃแ‰ต แАแ‹ แ‹˜แŒ แŠ แАแ‹ แˆตแˆ‹แˆแŠฉแ‰ต แ‹ฐแˆž แ‰ฅแ‹™แ‹Žแ‰ฝ
Earth Quakeแˆ แŠฅแ‹ซแˆˆ แ‰ แˆแˆˆแ‰ตแŠ“ แ‰ แˆถแˆตแ‰ต Combination แˆฒแˆฐแˆฉ
แˆตแˆ‹แ‹จแ‹ แАแ‹แกแก แŠฅแŠ•แŒ‚ แŒแ‹ดแ‰ณ 7 แ‹ˆแ‹ญ แˆแŠ“แˆแŠ• แˆ˜แˆ†แŠ• แ‹จแˆˆแ‰ แ‰ตแˆแกแก
แˆˆแˆแˆณแˆŒ Serviceability แ‰ฅแ‰ป แŠฎแŠ•แˆฒแ‹ฐแˆญ แŠซแ‹ฐแˆจแŒแŠ• แŠ แŠ•แ‹ต แŠฎแˆแ‰ฆ //
แˆ›แˆˆแ‰ตแˆ DL+LL// แˆŠแ‰ แ‰ƒ แ‹ญแ‰ฝแˆ‹แˆแกแก แ…แˆแ‰ แŒแˆแ… แˆตแˆ‹แˆแˆ†แАแŠ“
แ‹ˆแ‹ณแˆแˆ†แА แŠ แ‰…แŒฃแŒซ แŠฅแŠ•แ‹ณแ‹ญแ‹ˆแˆฐแ‹ต แŠ แŠ•แˆตแ‰ผแ‹‹แˆˆแ‹แกแก
.
๐Ÿ‘‰แˆˆแ‰ฐแŒจแˆ›แˆœ แ‹จ แŠฎแŠ•แˆตแ‰ตแˆซแŠญแˆฝแŠ• แŠฅแ‹แ‰€แ‰ถแ‰ฝ...
๐Ÿšฉ แŠฅแ‹šแˆ… แ‹ญแŒซแŠ‘
๐Ÿ‘‡๐Ÿ‘‡๐Ÿ‘‡๐Ÿ‘‡๐Ÿ‘‡
https://telegram.me/COTMp