๐TYPES OF STAIRS: @COTMp
.
โถDepending upon the various arrangement of steps, stairs can be classified under following categories:
1. STRAIGHT STAIR:
In this stair, all the steps are arranged continuously
along in one direction. One flight may be split into
one or more than one flight by interposing a
landing. This stair can be used where narrow and
long space is available for a staircase such as
entrance, porch etc.
2. DOGGED-LEGGED STAIR:
This stair consists of two straight flights of steps
with direct turns between them. This stair is very
useful where the total width of the stair is just twice
the width of the steps.
3. OPEN NEWEL STAIR:
This type of stair consists of two or more flights
arranging a well or opening between the backward
and forward flights. When all the steps are difficult
to arrange in two flights, a short third flight of 3 to
6 steps may be provided along the direction
perpendicular to the hall. Open newel stair is mostly
adopted in the lift.
4. GEOMETRICAL STAIR:
This is another type of open newel stair where the
open well between the forward and the backward
flight is curved. This stair may contain different
geometrical shape. Here the change in direction is
achieved by using winders.
5. CIRCULAR STAIR:
In this type of stair, all the steps radiate from a
newel or well hole, in the form of winders. The
circular stair is adopted at the back side of a
building to access its various floors.
6. SPIRAL STAIR:
Spiral stair is very similar to a circular stair. It
consists of individual steps or treads, connecting to
a centre column. The overall diameter of the stair
may range from 1 to 2.5 m.
7. QUARTER-TURN STAIR:
The quarter-turn stair can be defined as the stairs
that are turned at 90 degrees with the help of level
landing.
8. BIFURCATED STAIR:
This type of stair is provided in modern public
buildings as well as residential buildings. In this
stair, the flight is so arranged that there is a wide
flight at the start which is sub-divided into narrow
flights at the mid-landing. The narrow flights start
from either side of the mid landing.
.
๐ฉJoin for more Discussion @COTMA
๐๐๐๐๐๐
@COTMA @COTMA @COTMA
.
โถDepending upon the various arrangement of steps, stairs can be classified under following categories:
1. STRAIGHT STAIR:
In this stair, all the steps are arranged continuously
along in one direction. One flight may be split into
one or more than one flight by interposing a
landing. This stair can be used where narrow and
long space is available for a staircase such as
entrance, porch etc.
2. DOGGED-LEGGED STAIR:
This stair consists of two straight flights of steps
with direct turns between them. This stair is very
useful where the total width of the stair is just twice
the width of the steps.
3. OPEN NEWEL STAIR:
This type of stair consists of two or more flights
arranging a well or opening between the backward
and forward flights. When all the steps are difficult
to arrange in two flights, a short third flight of 3 to
6 steps may be provided along the direction
perpendicular to the hall. Open newel stair is mostly
adopted in the lift.
4. GEOMETRICAL STAIR:
This is another type of open newel stair where the
open well between the forward and the backward
flight is curved. This stair may contain different
geometrical shape. Here the change in direction is
achieved by using winders.
5. CIRCULAR STAIR:
In this type of stair, all the steps radiate from a
newel or well hole, in the form of winders. The
circular stair is adopted at the back side of a
building to access its various floors.
6. SPIRAL STAIR:
Spiral stair is very similar to a circular stair. It
consists of individual steps or treads, connecting to
a centre column. The overall diameter of the stair
may range from 1 to 2.5 m.
7. QUARTER-TURN STAIR:
The quarter-turn stair can be defined as the stairs
that are turned at 90 degrees with the help of level
landing.
8. BIFURCATED STAIR:
This type of stair is provided in modern public
buildings as well as residential buildings. In this
stair, the flight is so arranged that there is a wide
flight at the start which is sub-divided into narrow
flights at the mid-landing. The narrow flights start
from either side of the mid landing.
.
๐ฉJoin for more Discussion @COTMA
๐๐๐๐๐๐
@COTMA @COTMA @COTMA
๐SLUMP TEST OF CONCRETE @COTMp
~~~~~~~~~~~~~~~~
โถThe concrete slump test is an empirical test that
measures the workability of fresh concrete. The test
is performed to check the consistency of freshly
mixed concrete in a specific batch. *Consistency refers to the ease and homogeneity with which the concrete can be mixed, placed, compacted and finished. *This test is most widely used due to the simplicity of apparatus and simple test procedure.
*The slump test gives satisfactory results for the
concrete mix of medium to high workability and
unfortunately, it does not give the correct indication
of low workability, which may give zero slumps.
This test is also known as slump cone test.
โถAPPARATUS FOR CONCRETE SLUMP TEST:
1. Mould or slump cone with a height of 300 mm,
bottom diameter 200 mm, and top diameter 100
mm.
2. Standard tamping rod.
3. Non-porous base plate.
4. Measuring scale.
โถPROCEDURE OF TEST:
1. First, clean the inner surface of the empty mould and then apply oil to it.
2. Set the mould on a horizontal non-porous and
non-absorbent base plate.
3. Fill the mould fully by pouring freshly mixed
concrete in three equal layers.
4. Stroke each layer 25 times with the standard
tamping rod over the cross section.
5. After stroking 25 times the top layer is struck off
level, now lift the mould slowly in the vertical
direction without disturbing the concrete cone.
6. Use the measuring scale to measure the difference level between the height of the mould and the concrete sample.
*The subsidence of concrete is known as the slump and the value of slump is measured in mm.
โถTYPES OF SLUMP:
*True Slump: The concrete mass after the test when
slumps evenly all around without disintegration is
called the true slump.
*Shear Slump: When one-half of the concrete mass
slide down the other is called the shear slump. This type of slump is obtained in a lean concrete mix.
*Collapse Slump: When the sample is collapsed due to adding excessive water, it is known as collapse slump.
*Zero Slump: For very stiff or dry mixes it does not
show any changes of the slump after removing the
slump cone.
โถADVANTAGES OF CONCRETE SLUMP TEST:
1. The procedure of slump test is simple and easy
than any other workability test.
2. Inexpensive and portable apparatus are required
for this test.
3. Slump test can be performed at the construction site as well as in the laboratory.
โถLIMITATIONS OF CONCRETE SLUMP TEST:
1. The slump test is limited to concretes with the
maximum size of aggregate less than 38 mm.
2. The test is suitable only for concretes of medium
or high workabilities (i.e having slump values of 25
mm to 125 mm).
3. For very stiff mixes having zero slumps, the
slump test does not show any difference in concretes of different workabilities.
*Recommended Values Of Slumps For Different
Concrete Mixes:
โถTypes Of Concrete Slump Range In mm
1. Heavy mass construction 25-50
2. Pavements 20-30
3. Bridge deck 25-75
4. Beams and slabs 50-100
5. Columns, retaining
walls and thin vertical members etc. 75-150
6. Vibrated concrete 12-25
.
๐ฉแผแญ แ แแญแ แแแแ แฅแแณแญแตแข
~~~~~~~~~~~~~~~~
โถThe concrete slump test is an empirical test that
measures the workability of fresh concrete. The test
is performed to check the consistency of freshly
mixed concrete in a specific batch. *Consistency refers to the ease and homogeneity with which the concrete can be mixed, placed, compacted and finished. *This test is most widely used due to the simplicity of apparatus and simple test procedure.
*The slump test gives satisfactory results for the
concrete mix of medium to high workability and
unfortunately, it does not give the correct indication
of low workability, which may give zero slumps.
This test is also known as slump cone test.
โถAPPARATUS FOR CONCRETE SLUMP TEST:
1. Mould or slump cone with a height of 300 mm,
bottom diameter 200 mm, and top diameter 100
mm.
2. Standard tamping rod.
3. Non-porous base plate.
4. Measuring scale.
โถPROCEDURE OF TEST:
1. First, clean the inner surface of the empty mould and then apply oil to it.
2. Set the mould on a horizontal non-porous and
non-absorbent base plate.
3. Fill the mould fully by pouring freshly mixed
concrete in three equal layers.
4. Stroke each layer 25 times with the standard
tamping rod over the cross section.
5. After stroking 25 times the top layer is struck off
level, now lift the mould slowly in the vertical
direction without disturbing the concrete cone.
6. Use the measuring scale to measure the difference level between the height of the mould and the concrete sample.
*The subsidence of concrete is known as the slump and the value of slump is measured in mm.
โถTYPES OF SLUMP:
*True Slump: The concrete mass after the test when
slumps evenly all around without disintegration is
called the true slump.
*Shear Slump: When one-half of the concrete mass
slide down the other is called the shear slump. This type of slump is obtained in a lean concrete mix.
*Collapse Slump: When the sample is collapsed due to adding excessive water, it is known as collapse slump.
*Zero Slump: For very stiff or dry mixes it does not
show any changes of the slump after removing the
slump cone.
โถADVANTAGES OF CONCRETE SLUMP TEST:
1. The procedure of slump test is simple and easy
than any other workability test.
2. Inexpensive and portable apparatus are required
for this test.
3. Slump test can be performed at the construction site as well as in the laboratory.
โถLIMITATIONS OF CONCRETE SLUMP TEST:
1. The slump test is limited to concretes with the
maximum size of aggregate less than 38 mm.
2. The test is suitable only for concretes of medium
or high workabilities (i.e having slump values of 25
mm to 125 mm).
3. For very stiff mixes having zero slumps, the
slump test does not show any difference in concretes of different workabilities.
*Recommended Values Of Slumps For Different
Concrete Mixes:
โถTypes Of Concrete Slump Range In mm
1. Heavy mass construction 25-50
2. Pavements 20-30
3. Bridge deck 25-75
4. Beams and slabs 50-100
5. Columns, retaining
walls and thin vertical members etc. 75-150
6. Vibrated concrete 12-25
.
๐ฉแผแญ แ แแญแ แแแแ แฅแแณแญแตแข
๐OPC VS PPC cement @COTMp
.
โถPPC: PPC or Portland Pozzolan's Cement is a mixture of Pozzolan's panic material with Argillaceous and Calcareous materials in powdered form. *Pozzolan's increases the strength of the cement but initial setting time is more than OPC.
*Pozzolan's should be in the range of 10โ30%. If more than this range
then strength will be reduced.
*It is useful for most
Civil construction works like mass concreting etc. It
is economical for projects as less cost of cement
than OPC. Gypsum is used for controlling of setting
time.
โถADVANTAGES OF PPC:
1. Higher durability of concrete structure due to less permeability of water.
2. More resistance towards the attack of alkalies,
sulfates, chlorides, chemicals.
3. Better workability.
4. Low heat of hydration.
5. Due to high fineness, PPC has better cohesion
with aggregates and makes more dense
concreteness.
6. Comparative lower Water-Cement ratio provides an added advantage for the further increase of compressive strength of the concrete.
7. Better surface finish.
.
โกOPC: OPC or Ordinary Portland Cement is a mixture of Calcareous materials with Argillaceous material in
proportional ratio. Gypsum is used for controlling
the setting time. It has less setting time than PPC.
It is useful where work to be complete soon. It is
costlier than PPC. It is available in various grades
such 33, 43 & 53. OPC grade 43 is very useful
nowadays.
โถADVANTAGES OF OPC:
1. Produces highly durable and sound concrete due
to very low percentage of alkalis, chlorides,
magnesia and free lime in its composition.
2. Almost negligible chloride content results in
restraining corrosion of concrete structure in hostile environments.
3. Significant saving in cement consumption while
making concrete of grades M15, M20, M25, M35
and pre-cast segments due to high strength.
โถDIFFERENCE BETWEEN OPC AND PPC:
โกORDINARY PORTLAND CEMENT (OPC):
1. OPC is produced simply by grinding limestone
and secondary materials to a powder.
*The main raw materials used for manufacturing OPC is calcareous material, argillaceous material, and gypsum.
2. The durability of OPC is lower than PPC.
3. The setting time is of OPC is less than PPC.
4. Costlier than PPC.
5. Mostly used where fast construction is required.
6. The different grades of OPC are:
*OPC 33 Grade
*OPC 43 Grade
*OPC 53 Grade
.
โถPOZZOLANIC PORTLAND CEMENT (PPC):
1. PPC is a variation of OPC which includes a
mixture of a pozzolanic material which is known to
increase the strength of concrete. The raw materials used for manufacturing of PPC is OPC, gypsum, pozzolanic materials such as fly ash, rice husk ash, volcanic tuffs and pumicites, clay & shale, etc.
2. Mostly used in mass concreting, plaster and
masonry.
3. Durability is high.
4. Setting time is greater than OPC.
5. Curing period is a little higher than OPC.
6. It can be used in all type of construction work.
7. There are no such specific grades of PPC like
OPC.
8. Low cost.
.
๐๐๐๐๐
Join for more updates via the link below;
t.me/COTMp
๐๐๐๐๐
โก แ แแแ Join แ แแจแ แฅแ แแแฐแแ แฅแ แแแซแแต แแ แผแญ แซแตแญแแข
.
โถPPC: PPC or Portland Pozzolan's Cement is a mixture of Pozzolan's panic material with Argillaceous and Calcareous materials in powdered form. *Pozzolan's increases the strength of the cement but initial setting time is more than OPC.
*Pozzolan's should be in the range of 10โ30%. If more than this range
then strength will be reduced.
*It is useful for most
Civil construction works like mass concreting etc. It
is economical for projects as less cost of cement
than OPC. Gypsum is used for controlling of setting
time.
โถADVANTAGES OF PPC:
1. Higher durability of concrete structure due to less permeability of water.
2. More resistance towards the attack of alkalies,
sulfates, chlorides, chemicals.
3. Better workability.
4. Low heat of hydration.
5. Due to high fineness, PPC has better cohesion
with aggregates and makes more dense
concreteness.
6. Comparative lower Water-Cement ratio provides an added advantage for the further increase of compressive strength of the concrete.
7. Better surface finish.
.
โกOPC: OPC or Ordinary Portland Cement is a mixture of Calcareous materials with Argillaceous material in
proportional ratio. Gypsum is used for controlling
the setting time. It has less setting time than PPC.
It is useful where work to be complete soon. It is
costlier than PPC. It is available in various grades
such 33, 43 & 53. OPC grade 43 is very useful
nowadays.
โถADVANTAGES OF OPC:
1. Produces highly durable and sound concrete due
to very low percentage of alkalis, chlorides,
magnesia and free lime in its composition.
2. Almost negligible chloride content results in
restraining corrosion of concrete structure in hostile environments.
3. Significant saving in cement consumption while
making concrete of grades M15, M20, M25, M35
and pre-cast segments due to high strength.
โถDIFFERENCE BETWEEN OPC AND PPC:
โกORDINARY PORTLAND CEMENT (OPC):
1. OPC is produced simply by grinding limestone
and secondary materials to a powder.
*The main raw materials used for manufacturing OPC is calcareous material, argillaceous material, and gypsum.
2. The durability of OPC is lower than PPC.
3. The setting time is of OPC is less than PPC.
4. Costlier than PPC.
5. Mostly used where fast construction is required.
6. The different grades of OPC are:
*OPC 33 Grade
*OPC 43 Grade
*OPC 53 Grade
.
โถPOZZOLANIC PORTLAND CEMENT (PPC):
1. PPC is a variation of OPC which includes a
mixture of a pozzolanic material which is known to
increase the strength of concrete. The raw materials used for manufacturing of PPC is OPC, gypsum, pozzolanic materials such as fly ash, rice husk ash, volcanic tuffs and pumicites, clay & shale, etc.
2. Mostly used in mass concreting, plaster and
masonry.
3. Durability is high.
4. Setting time is greater than OPC.
5. Curing period is a little higher than OPC.
6. It can be used in all type of construction work.
7. There are no such specific grades of PPC like
OPC.
8. Low cost.
.
๐๐๐๐๐
Join for more updates via the link below;
t.me/COTMp
๐๐๐๐๐
โก แ แแแ Join แ แแจแ แฅแ แแแฐแแ แฅแ แแแซแแต แแ แผแญ แซแตแญแแข
Telegram
ETCONp Discussion
๐ฉแแแแแแ แแณแฅ แฅแ แ แตแฐแซแจแต @Philemona7
โ๏ธแญแ แจ @etconp แแแซแซ แแฉแแน แแแข
โThis is discussion group of @ETCONpWORK
.
๐แแณแฐแฅแซ ...
.
โก๏ธแแฉแ แแญ แแแแแ แจ แฎแแตแตแซแญแฝแ แแณแฎแฝ แแช แแแ แ แ แแแ แ แญแแแตแ!
@ETCONpBOT แแแแ แฅแแแฐแแแแ๐
โ๏ธแญแ แจ @etconp แแแซแซ แแฉแแน แแแข
โThis is discussion group of @ETCONpWORK
.
๐แแณแฐแฅแซ ...
.
โก๏ธแแฉแ แแญ แแแแแ แจ แฎแแตแตแซแญแฝแ แแณแฎแฝ แแช แแแ แ แ แแแ แ แญแแแตแ!
@ETCONpBOT แแแแ แฅแแแฐแแแแ๐
๐BASICS OF CRACKING PROBLEMS: @COTMp
.
โถThe subject โ CRACKS โ or โ CRACKING โ in
concrete is indeed much debated. However, there is
inadequate clarity as to the reason for cracking and
what mey be done to limit its occurrence or
eliminate it altogether.
The phenomenon of the appearance of cracks in
concrete is often a subject that raises several
questions. Either at the initial stage or with time,
cracks may appear in a concrete structure. It should
first of all be accepted that cracks of some type or
other are inevitable in any concrete. They can be
minimized to a large extent by proper practices.
Cracks may be big or small, structural or non-
structural. All of them can be a nuisance by way of
either marring the appearance or function as a
passage for atmospheric polluting gases and
moisture to either the body of concrete and causes
distress.
Cracks in the concrete structure do not always
mean that the structure is not useable. As cracking
of concrete is inherent, what really matters is the
type of structure and the nature of cracking. Cracks
that are acceptable for building structures may not
be acceptable for water relating structures.
Considering that cracking xan never be completely
eliminated, it is necessary to be aware of the
causes, evaluation and the methods of repair
whoever required.
CRACKS
Cracks are generally of towtypes : Structural and
non-structural. Cracks can occur in hardened or
unhardened concrete.
STRUCTURAL CRACKS
It is fundamental that hardened reinforced concrete
cracks in the tensile zone when subjected to
externally imposed structural loads. By means of
appropriate design and detailing technique, these
cracks can be limited to acceptable levels in terms
of structural integrity and aesthetics.
NON_STRUCTURAL CRACKS
Concrete is also liable to crack in both the plastic
and hardened states due to the nature of its
constituent materials. These intrinsic cracks are as
inevitable as structural cracks. Ti is often possible
to predict when intrinsic cracks are likely and to
limit them to acceptable levels by means of good
design and/or proper construction techniques.
DORMANT AND LIVE CRACKS:
Cracks caused by shrinkage, temperature gradient
due to hydration and alkali silica reaction ( ASR )
are less dangerous the cracks caused by thermal
expansion and loads. This is because shrinkage
and hydration temperature gradient result in
dormant cracks ( where the width does not vary
with time) and other mechanisms result in live
cracks (where the width increases with time
Dormant cracks, especially narrow ones, are more
likely to undergo autogenous healing and
realkalisation. The crack may heal owing to
following conditions:
โข carbon dioxide diffusing into the crack leading to
carbonation of the calcium hydroxide and
precipitation of calcium carbonate.
โข Cement hydration due to presence of moisture.
โข Hydration diffusing from the bulk concrete into the
heaked zone thereby increasing the pH in that area.
Live cracks are more likely than domant ones. They
result in collection of debris at the base owing to
movement of the sides on the cracks. This can
impede temporarily the passage of depassivating
substances to the reinforcements. However,
autodeneous healing is unlikely with live cracks.
CAUSES OF CRACKING:
Cracking will occur whenever the applied strain
exceeds the tensile strain capacity of the concrete.
The tensile strain capacity of concrete varies with
age and with
Age at which cracks may occur.
Cracks can appear at any time. The age which
some typical can occur are given in the Table.
TABLE โ AGE AT WHICH CRACKS MAY APPEAR:
Sr. no. types of cracks Age
1. plastic shrinkage First few minutes or hours after
concreting .
2. plastic settlement First few minutes or hours
after concreting.
3. due to corrosion After one year or many years.
4. due to loads After loads are imposed and the
time duration of loading
5. due to weight Just after formwork support are
removed.๐๐๐
.
โถThe subject โ CRACKS โ or โ CRACKING โ in
concrete is indeed much debated. However, there is
inadequate clarity as to the reason for cracking and
what mey be done to limit its occurrence or
eliminate it altogether.
The phenomenon of the appearance of cracks in
concrete is often a subject that raises several
questions. Either at the initial stage or with time,
cracks may appear in a concrete structure. It should
first of all be accepted that cracks of some type or
other are inevitable in any concrete. They can be
minimized to a large extent by proper practices.
Cracks may be big or small, structural or non-
structural. All of them can be a nuisance by way of
either marring the appearance or function as a
passage for atmospheric polluting gases and
moisture to either the body of concrete and causes
distress.
Cracks in the concrete structure do not always
mean that the structure is not useable. As cracking
of concrete is inherent, what really matters is the
type of structure and the nature of cracking. Cracks
that are acceptable for building structures may not
be acceptable for water relating structures.
Considering that cracking xan never be completely
eliminated, it is necessary to be aware of the
causes, evaluation and the methods of repair
whoever required.
CRACKS
Cracks are generally of towtypes : Structural and
non-structural. Cracks can occur in hardened or
unhardened concrete.
STRUCTURAL CRACKS
It is fundamental that hardened reinforced concrete
cracks in the tensile zone when subjected to
externally imposed structural loads. By means of
appropriate design and detailing technique, these
cracks can be limited to acceptable levels in terms
of structural integrity and aesthetics.
NON_STRUCTURAL CRACKS
Concrete is also liable to crack in both the plastic
and hardened states due to the nature of its
constituent materials. These intrinsic cracks are as
inevitable as structural cracks. Ti is often possible
to predict when intrinsic cracks are likely and to
limit them to acceptable levels by means of good
design and/or proper construction techniques.
DORMANT AND LIVE CRACKS:
Cracks caused by shrinkage, temperature gradient
due to hydration and alkali silica reaction ( ASR )
are less dangerous the cracks caused by thermal
expansion and loads. This is because shrinkage
and hydration temperature gradient result in
dormant cracks ( where the width does not vary
with time) and other mechanisms result in live
cracks (where the width increases with time
Dormant cracks, especially narrow ones, are more
likely to undergo autogenous healing and
realkalisation. The crack may heal owing to
following conditions:
โข carbon dioxide diffusing into the crack leading to
carbonation of the calcium hydroxide and
precipitation of calcium carbonate.
โข Cement hydration due to presence of moisture.
โข Hydration diffusing from the bulk concrete into the
heaked zone thereby increasing the pH in that area.
Live cracks are more likely than domant ones. They
result in collection of debris at the base owing to
movement of the sides on the cracks. This can
impede temporarily the passage of depassivating
substances to the reinforcements. However,
autodeneous healing is unlikely with live cracks.
CAUSES OF CRACKING:
Cracking will occur whenever the applied strain
exceeds the tensile strain capacity of the concrete.
The tensile strain capacity of concrete varies with
age and with
Age at which cracks may occur.
Cracks can appear at any time. The age which
some typical can occur are given in the Table.
TABLE โ AGE AT WHICH CRACKS MAY APPEAR:
Sr. no. types of cracks Age
1. plastic shrinkage First few minutes or hours after
concreting .
2. plastic settlement First few minutes or hours
after concreting.
3. due to corrosion After one year or many years.
4. due to loads After loads are imposed and the
time duration of loading
5. due to weight Just after formwork support are
removed.๐๐๐
6. due to chemical changes in hardened
concrete After one or many years depending in
chemical attack from outside (sulphate ) Or
chemical reaction from within (ASR)
.
โถCRITICAL CRACK WIDTH: The most common reasons for controlling crack
width are following:
APPERANCE : Unsightly cracking should be avoid
since it may cause concern to the occupants of the external structure.
Ti may also contribute to
unsightly staining on exposed external surfaces,
where salts and rust are washed out from the crack.
DURABILITY: Excessively wide cracks may lead to
corrosion of the reinforcement which in turn may lead to spalling of concrete due to the expansive nature of the corrosion process.
WATER-TIGHTNESS: This is of importance in water
retaining structures.
In particular instances there may be other reasons for controlling cracking in addition to the three reasons cited above.
Crack width is, generally, to be taken to mean the
measurable width of a crack at the surface of
concrete. Crack width limitation is important from durability considerations. Most structural codes
prescribe maximum allowed crack widths.
Codes normally consider cracking caused by
external imposed conditions such as live loading
and provide formula for calculating the crack width
in the design phase. Mainly bending and tension or
bending and axial load are considered. The
direction of such cracks is perpendicular to the
direction of the main reinforcement. Plastic
shrinkage cracks follow the line of reinforcement.
According to IS: 456-2000 the surface of the width
of the cracks should not in general exceeds o.3 mm
in members where cracking is not harmful and does
not have any serious effect either on the
preservation of reinforceing steel or on the durability
of the structures.
In members, where cracking of the tensile zone is
harmful either because they are moisture or in
contact with soil or groundwater, an upper limlt of
0.2 mm is suggested.
For aggressive conditions the surface width of
cracks should not generally exceed 0.1 mm. The
crack width conditions the surface width of cracks
should not be generally exceed 0.1 mm. The crack
width is measured at the surface for the above
purposes. However some other codes specify the
width at points near the reinforcement.
.
๐ฉShare Share Share
concrete After one or many years depending in
chemical attack from outside (sulphate ) Or
chemical reaction from within (ASR)
.
โถCRITICAL CRACK WIDTH: The most common reasons for controlling crack
width are following:
APPERANCE : Unsightly cracking should be avoid
since it may cause concern to the occupants of the external structure.
Ti may also contribute to
unsightly staining on exposed external surfaces,
where salts and rust are washed out from the crack.
DURABILITY: Excessively wide cracks may lead to
corrosion of the reinforcement which in turn may lead to spalling of concrete due to the expansive nature of the corrosion process.
WATER-TIGHTNESS: This is of importance in water
retaining structures.
In particular instances there may be other reasons for controlling cracking in addition to the three reasons cited above.
Crack width is, generally, to be taken to mean the
measurable width of a crack at the surface of
concrete. Crack width limitation is important from durability considerations. Most structural codes
prescribe maximum allowed crack widths.
Codes normally consider cracking caused by
external imposed conditions such as live loading
and provide formula for calculating the crack width
in the design phase. Mainly bending and tension or
bending and axial load are considered. The
direction of such cracks is perpendicular to the
direction of the main reinforcement. Plastic
shrinkage cracks follow the line of reinforcement.
According to IS: 456-2000 the surface of the width
of the cracks should not in general exceeds o.3 mm
in members where cracking is not harmful and does
not have any serious effect either on the
preservation of reinforceing steel or on the durability
of the structures.
In members, where cracking of the tensile zone is
harmful either because they are moisture or in
contact with soil or groundwater, an upper limlt of
0.2 mm is suggested.
For aggressive conditions the surface width of
cracks should not generally exceed 0.1 mm. The
crack width conditions the surface width of cracks
should not be generally exceed 0.1 mm. The crack
width is measured at the surface for the above
purposes. However some other codes specify the
width at points near the reinforcement.
.
๐ฉShare Share Share
๐TYPES OF STAIRS: @COTMp
.
โถDepending upon the various arrangement of steps, stairs can be classified under following categories:
1. STRAIGHT STAIR:
In this stair, all the steps are arranged continuously
along in one direction. One flight may be split into
one or more than one flight by interposing a
landing. This stair can be used where narrow and
long space is available for a staircase such as
entrance, porch etc.
2. DOGGED-LEGGED STAIR:
This stair consists of two straight flights of steps
with direct turns between them. This stair is very
useful where the total width of the stair is just twice
the width of the steps.
3. OPEN NEWEL STAIR:
This type of stair consists of two or more flights
arranging a well or opening between the backward
and forward flights. When all the steps are difficult
to arrange in two flights, a short third flight of 3 to
6 steps may be provided along the direction
perpendicular to the hall. Open newel stair is mostly
adopted in the lift.
4. GEOMETRICAL STAIR:
This is another type of open newel stair where the
open well between the forward and the backward
flight is curved. This stair may contain different
geometrical shape. Here the change in direction is
achieved by using winders.
5. CIRCULAR STAIR:
In this type of stair, all the steps radiate from a
newel or well hole, in the form of winders. The
circular stair is adopted at the back side of a
building to access its various floors.
6. SPIRAL STAIR:
Spiral stair is very similar to a circular stair. It
consists of individual steps or treads, connecting to
a centre column. The overall diameter of the stair
may range from 1 to 2.5 m.
7. QUARTER-TURN STAIR:
The quarter-turn stair can be defined as the stairs
that are turned at 90 degrees with the help of level
landing.
8. BIFURCATED STAIR:
This type of stair is provided in modern public
buildings as well as residential buildings. In this
stair, the flight is so arranged that there is a wide
flight at the start which is sub-divided into narrow
flights at the mid-landing. The narrow flights start
from either side of the mid landing.
.
๐ฉGo for Conversation
๐๐๐๐๐
@COTMA
.
โถDepending upon the various arrangement of steps, stairs can be classified under following categories:
1. STRAIGHT STAIR:
In this stair, all the steps are arranged continuously
along in one direction. One flight may be split into
one or more than one flight by interposing a
landing. This stair can be used where narrow and
long space is available for a staircase such as
entrance, porch etc.
2. DOGGED-LEGGED STAIR:
This stair consists of two straight flights of steps
with direct turns between them. This stair is very
useful where the total width of the stair is just twice
the width of the steps.
3. OPEN NEWEL STAIR:
This type of stair consists of two or more flights
arranging a well or opening between the backward
and forward flights. When all the steps are difficult
to arrange in two flights, a short third flight of 3 to
6 steps may be provided along the direction
perpendicular to the hall. Open newel stair is mostly
adopted in the lift.
4. GEOMETRICAL STAIR:
This is another type of open newel stair where the
open well between the forward and the backward
flight is curved. This stair may contain different
geometrical shape. Here the change in direction is
achieved by using winders.
5. CIRCULAR STAIR:
In this type of stair, all the steps radiate from a
newel or well hole, in the form of winders. The
circular stair is adopted at the back side of a
building to access its various floors.
6. SPIRAL STAIR:
Spiral stair is very similar to a circular stair. It
consists of individual steps or treads, connecting to
a centre column. The overall diameter of the stair
may range from 1 to 2.5 m.
7. QUARTER-TURN STAIR:
The quarter-turn stair can be defined as the stairs
that are turned at 90 degrees with the help of level
landing.
8. BIFURCATED STAIR:
This type of stair is provided in modern public
buildings as well as residential buildings. In this
stair, the flight is so arranged that there is a wide
flight at the start which is sub-divided into narrow
flights at the mid-landing. The narrow flights start
from either side of the mid landing.
.
๐ฉGo for Conversation
๐๐๐๐๐
@COTMA
๐TOP 8 TYPES OF ESTIMATE IN CONSTRUCTION WORKS @COTMp
.
โถVarious types of estimates as prepared
are of following types:-
1. Approximate or Preliminary Estimate
The estimate is prepared to know the approximate cost of the work and to take the administrative approval by the competent authority of the department for which the work is to be executed this
estimate is also called as *ROUGH COST ESTIMATE. The cost of building, cost of land, cost of roads etc. are shown separately in this estimate.
The necessity and urgency of the estimate and rates
arrived at for knowing the cost are fully explained in this estimate.
The specifications to be adopted are also fully explained. The rates provided in the estimate and for unit basis i.e., per sq.m for buildings, per km length of road or canal and per running meter of span for culverts and bridges.
2. Plinth Area Estimate
The estimate prepared on the plinth area basis of the building by using suitable
plinth area rates is called the plinth area estimate. The area of the building at the plinth level, by taking the external dimensions is worked out and is multiplied by suitable rate per sq m. The cost thus arrived at is the cost of
building based on plinth area. The plinth area rates for different types of buildings are different i.e., the rates for residential
buildings are less than the rates for the hospital buildings etc. Plinth area
estimate is also a rough cost estimate.
3. Cubical Content Estimate This estimate is also an approximate and
is prepared on the basis of cubical contents of the building. The cost of the
building is calculated by multiplying the plinth area by the height of building and cubical content rate i.e., plinth area multiplied by; height multiplied by;
cubical content rate. The plinth area is calculated as staved above and the
height is taken from the top of flat roof (or halfway of the sloped roof) to the top of concrete in foundation. The cubical
content rate is deduced from the cost of similar building in the locality. The
parapet is not taken in the calculations.
*This estimate is more accurate than the
plinth area estimate.
4. Detailed Estimate
After obtaining the administrative
approval of the concerned department against the rough cost estimate.
As this estimate is based on the plans and sections of the building so
it is the most accurate estimate. The quantities of items under various sub
heads of work are calculated from the drawings and cost of each item is worked out separately according to the prevalent market rates and is totaled. After doing the total of all items
a percentage of 3 to 5 is added for unforeseen items, change of design and provision of petty-establishment. Grand
total so obtained gives the estimated cost of building. This estimate is then
submitted to the competent authority for
according technical sanction.
The detailed estimate is accompanied by report,
design and scope, detailed drawings, detailed specifications, justification of the rates provided and the limit for execution
of the work. The work us executed according to the detailed estimate.
5. Revised Estimate
When the cost of the estimate exceeds
or likely to increase by 10% or more, a revised estimate is required to be
prepared.
It is accompanied by the
comparative statement showing the variations of each item of work and
giving the reasons of excess.
6. Supplementary Estimate
When some addition to the original work is made a fresh detailed estimate for the additional work is prepared to supplement the original estimate
7. Annual Repair of Annual Maintenance Estimate This estimate is prepared to carry out annual repairs or maintenance.
8. Extension and Improvement Estimate
When some changes and extensions are required to be made in the old work, the cost of which cannot be met by the annual repair/maintenance estimate, a detailed estimate is prepared for such work which is called as Extension and Improvement estimate.
.
๐ฉแผแญ แ แแตแจแ แแแณแ แ แซแแฉแข แฅแแแฐแแแแแข
.
โถVarious types of estimates as prepared
are of following types:-
1. Approximate or Preliminary Estimate
The estimate is prepared to know the approximate cost of the work and to take the administrative approval by the competent authority of the department for which the work is to be executed this
estimate is also called as *ROUGH COST ESTIMATE. The cost of building, cost of land, cost of roads etc. are shown separately in this estimate.
The necessity and urgency of the estimate and rates
arrived at for knowing the cost are fully explained in this estimate.
The specifications to be adopted are also fully explained. The rates provided in the estimate and for unit basis i.e., per sq.m for buildings, per km length of road or canal and per running meter of span for culverts and bridges.
2. Plinth Area Estimate
The estimate prepared on the plinth area basis of the building by using suitable
plinth area rates is called the plinth area estimate. The area of the building at the plinth level, by taking the external dimensions is worked out and is multiplied by suitable rate per sq m. The cost thus arrived at is the cost of
building based on plinth area. The plinth area rates for different types of buildings are different i.e., the rates for residential
buildings are less than the rates for the hospital buildings etc. Plinth area
estimate is also a rough cost estimate.
3. Cubical Content Estimate This estimate is also an approximate and
is prepared on the basis of cubical contents of the building. The cost of the
building is calculated by multiplying the plinth area by the height of building and cubical content rate i.e., plinth area multiplied by; height multiplied by;
cubical content rate. The plinth area is calculated as staved above and the
height is taken from the top of flat roof (or halfway of the sloped roof) to the top of concrete in foundation. The cubical
content rate is deduced from the cost of similar building in the locality. The
parapet is not taken in the calculations.
*This estimate is more accurate than the
plinth area estimate.
4. Detailed Estimate
After obtaining the administrative
approval of the concerned department against the rough cost estimate.
As this estimate is based on the plans and sections of the building so
it is the most accurate estimate. The quantities of items under various sub
heads of work are calculated from the drawings and cost of each item is worked out separately according to the prevalent market rates and is totaled. After doing the total of all items
a percentage of 3 to 5 is added for unforeseen items, change of design and provision of petty-establishment. Grand
total so obtained gives the estimated cost of building. This estimate is then
submitted to the competent authority for
according technical sanction.
The detailed estimate is accompanied by report,
design and scope, detailed drawings, detailed specifications, justification of the rates provided and the limit for execution
of the work. The work us executed according to the detailed estimate.
5. Revised Estimate
When the cost of the estimate exceeds
or likely to increase by 10% or more, a revised estimate is required to be
prepared.
It is accompanied by the
comparative statement showing the variations of each item of work and
giving the reasons of excess.
6. Supplementary Estimate
When some addition to the original work is made a fresh detailed estimate for the additional work is prepared to supplement the original estimate
7. Annual Repair of Annual Maintenance Estimate This estimate is prepared to carry out annual repairs or maintenance.
8. Extension and Improvement Estimate
When some changes and extensions are required to be made in the old work, the cost of which cannot be met by the annual repair/maintenance estimate, a detailed estimate is prepared for such work which is called as Extension and Improvement estimate.
.
๐ฉแผแญ แ แแตแจแ แแแณแ แ แซแแฉแข แฅแแแฐแแแแแข
๐PROPERTIES OF HARDENED CONCRETE @COTMp
.
โถThe following are the properties of concrete
in its hardened state, used by the designer
during design process of reinforced concrete structure.
1. COMPRESSIVE STRENGTH
The characteristics strength is defined as
the strength of concrete below which not
more than 5% of the test results are expected to fall. As per IS: 456 concrete
mix always designed for the target strength
computed as,*Target strength: Characteristics strength + (1.65 x standard deviation) C-20 is the minimum grade of concrete for
use in RCC work.
2. TENSILE STRENGTH
Flexural strength is one measure of the
Tensile strength of concrete. In concrete
structure one set of visible cracks occur under flexure to compute load factor
against cracking .
According to IS: 456 the
tensile strength of concrete can be
computed from the compressive strength
using empirical relation given by:
Flexural strength: f =0.7โfck N/mm
3. MODULUS ELASTICITY
Modulus of elasticity of concrete which is
significantly influenced by the following
factors.
*Type of the aggregates used
*Type of cement and
*Mix proportions
***This property is required for the computations of deflections of strutural
concrete members which forms an
important limit state in the design of concrete members. In the absence of test data, the modulus of elasticity of concrete
is normally related to the compressive strength and is computed by the empirical relation recommended by IS: 456-2000 code and is expressed as,
E =5000โfck
Where E is the short term static modulus
of elasticity of concrete expressed in N/
mm
f is the characteristic compressive
strength of concrete expressed in N/mm .
4. SHRINKAGE OF CONCRETE
The ingredients of concrete and
environmental conditions like temperature
and humidity influence the total shrinkage
of concrete. Water content in concrete
significantly affects the shrinkage. The IS:
456-2000 recommends the total shrinkage
strain as 0.0003 in the absence of test
data. Drying shrinkage in plain concrete
may result in surface cracks. Shrinkage of
concrete also influences the deflections of
reinforced concrete members.
5. CREEP OF CONCRETE
The inelastic time dependent strain
developed in a concrete emeber under
sustained loading is refered to as creep of
concrete. Creep of concrete is influenced
by following factors.
Cement content,
W/C ratio,
Temperature and humidity,
Size of structural element,
Type of loading and period of loading.
In the absence of reliable experimental
data, the creep coefficient is expressed as
the ratio of ultimate creep strain/elastic
strain at various ages of loading as
recommended by IS: 456-2000 are given
below.
Age at Loading Creep Coefficient
7 days 2.2
28 days 1.6
1 year 1.1
Creep of concrete significantly affects the
deflections of reinforced concrete flexural
members. Higher creep coefficient results
in large deflections. The value of creep
coefficient is useful in the computation of
time dependent deflections in reinforced
concrete members.
6. COEFFICIENT OF THERMAL
EXPANSION
The coefficient of thermal expansion of
concrete, influenced mainly by the type of
aggregate used in concrete is required for
the design of structures like chimneys,
water tanks, silos etc.
.
๐ฉSHARE SHARE SHARE
.
โถThe following are the properties of concrete
in its hardened state, used by the designer
during design process of reinforced concrete structure.
1. COMPRESSIVE STRENGTH
The characteristics strength is defined as
the strength of concrete below which not
more than 5% of the test results are expected to fall. As per IS: 456 concrete
mix always designed for the target strength
computed as,*Target strength: Characteristics strength + (1.65 x standard deviation) C-20 is the minimum grade of concrete for
use in RCC work.
2. TENSILE STRENGTH
Flexural strength is one measure of the
Tensile strength of concrete. In concrete
structure one set of visible cracks occur under flexure to compute load factor
against cracking .
According to IS: 456 the
tensile strength of concrete can be
computed from the compressive strength
using empirical relation given by:
Flexural strength: f =0.7โfck N/mm
3. MODULUS ELASTICITY
Modulus of elasticity of concrete which is
significantly influenced by the following
factors.
*Type of the aggregates used
*Type of cement and
*Mix proportions
***This property is required for the computations of deflections of strutural
concrete members which forms an
important limit state in the design of concrete members. In the absence of test data, the modulus of elasticity of concrete
is normally related to the compressive strength and is computed by the empirical relation recommended by IS: 456-2000 code and is expressed as,
E =5000โfck
Where E is the short term static modulus
of elasticity of concrete expressed in N/
mm
f is the characteristic compressive
strength of concrete expressed in N/mm .
4. SHRINKAGE OF CONCRETE
The ingredients of concrete and
environmental conditions like temperature
and humidity influence the total shrinkage
of concrete. Water content in concrete
significantly affects the shrinkage. The IS:
456-2000 recommends the total shrinkage
strain as 0.0003 in the absence of test
data. Drying shrinkage in plain concrete
may result in surface cracks. Shrinkage of
concrete also influences the deflections of
reinforced concrete members.
5. CREEP OF CONCRETE
The inelastic time dependent strain
developed in a concrete emeber under
sustained loading is refered to as creep of
concrete. Creep of concrete is influenced
by following factors.
Cement content,
W/C ratio,
Temperature and humidity,
Size of structural element,
Type of loading and period of loading.
In the absence of reliable experimental
data, the creep coefficient is expressed as
the ratio of ultimate creep strain/elastic
strain at various ages of loading as
recommended by IS: 456-2000 are given
below.
Age at Loading Creep Coefficient
7 days 2.2
28 days 1.6
1 year 1.1
Creep of concrete significantly affects the
deflections of reinforced concrete flexural
members. Higher creep coefficient results
in large deflections. The value of creep
coefficient is useful in the computation of
time dependent deflections in reinforced
concrete members.
6. COEFFICIENT OF THERMAL
EXPANSION
The coefficient of thermal expansion of
concrete, influenced mainly by the type of
aggregate used in concrete is required for
the design of structures like chimneys,
water tanks, silos etc.
.
๐ฉSHARE SHARE SHARE
๐แแฌ แฐแ แตแ Load Combination แ แฃแฒแฑ แจ EBCS แฎแต แฃแฅแจแ แฅแแญ @COTMp
.
Combo 1= DL + LL
Combo 2= 1.35DL + 1.5LL
Combo 3= DL + 0.3LL + EQx
Combo 4= DL + 0.3LL - EQx
Combo 5= DL + 0.3LL + EQy
Combo 6= DL + 0.3LL - EQy
Combo 7= max( Combo 2 up to 6)
.
.
แแ แแ แขแ แแ แแแต แ แญแฐแแแกแก แแแณแ 0.3LL แจแแแ
แ แแแแ แจแแแ แแแ แDomestic/residential purpose
แจแแ แแแกแก Shop แจแแ 0.6LL storage แจแแ แฐแ 0.8LL
แญแแแแกแก แจแแ แ แ แฐแจแแช แแแ แแญแแ แแญ แจแฐแแซแฉ
แฎแแฒแฝแแฝ แตแแ แฅแแฑแ แแจแต แซแตแแแแแกแก แแแแธแแ EBCS
EN 1990: 2014 แจ Equation 6.9 แฅแตแจ 6.16 แแแกแก
แแญแแแแน แแตแฅ แจแแแกแตแ variable แแแแแต แฐแ
check the Annex part แฅแฉแตแข
.
combination แฐแฃแต แแ แแ แ แแ แตแแแฉแต แฐแ แฅแแแฝ
Earth Quakeแ แฅแซแ แ แแแตแ แ แถแตแต Combination แฒแฐแฉ
แตแแจแ แแแกแก แฅแแ แแดแณ 7 แแญ แแแแ แแแ แจแแ แตแแกแก
แแแณแ Serviceability แฅแป แฎแแฒแฐแญ แซแฐแจแแ แ แแต แฎแแฆ //
แแแตแ DL+LL// แแ แ แญแฝแแแกแก แ แแ แแแ แตแแแแแ
แแณแแแ แ แ แฃแซ แฅแแณแญแแฐแต แ แแตแผแแแแกแก
.
๐แแฐแจแแ แจ แฎแแตแตแซแญแฝแ แฅแแแถแฝ...
๐ฉ แฅแแ แญแซแ
๐๐๐๐๐
https://telegram.me/COTMp
.
Combo 1= DL + LL
Combo 2= 1.35DL + 1.5LL
Combo 3= DL + 0.3LL + EQx
Combo 4= DL + 0.3LL - EQx
Combo 5= DL + 0.3LL + EQy
Combo 6= DL + 0.3LL - EQy
Combo 7= max( Combo 2 up to 6)
.
.
แแ แแ แขแ แแ แแแต แ แญแฐแแแกแก แแแณแ 0.3LL แจแแแ
แ แแแแ แจแแแ แแแ แDomestic/residential purpose
แจแแ แแแกแก Shop แจแแ 0.6LL storage แจแแ แฐแ 0.8LL
แญแแแแกแก แจแแ แ แ แฐแจแแช แแแ แแญแแ แแญ แจแฐแแซแฉ
แฎแแฒแฝแแฝ แตแแ แฅแแฑแ แแจแต แซแตแแแแแกแก แแแแธแแ EBCS
EN 1990: 2014 แจ Equation 6.9 แฅแตแจ 6.16 แแแกแก
แแญแแแแน แแตแฅ แจแแแกแตแ variable แแแแแต แฐแ
check the Annex part แฅแฉแตแข
.
combination แฐแฃแต แแ แแ แ แแ แตแแแฉแต แฐแ แฅแแแฝ
Earth Quakeแ แฅแซแ แ แแแตแ แ แถแตแต Combination แฒแฐแฉ
แตแแจแ แแแกแก แฅแแ แแดแณ 7 แแญ แแแแ แแแ แจแแ แตแแกแก
แแแณแ Serviceability แฅแป แฎแแฒแฐแญ แซแฐแจแแ แ แแต แฎแแฆ //
แแแตแ DL+LL// แแ แ แญแฝแแแกแก แ แแ แแแ แตแแแแแ
แแณแแแ แ แ แฃแซ แฅแแณแญแแฐแต แ แแตแผแแแแกแก
.
๐แแฐแจแแ แจ แฎแแตแตแซแญแฝแ แฅแแแถแฝ...
๐ฉ แฅแแ แญแซแ
๐๐๐๐๐
https://telegram.me/COTMp
Telegram
ETCONp Discussion
โ๏ธแญแ
แจ @etconp แแแซแซ แแฉแแน แแแข
โThis is discussion group of @ETCONpWORK
.
๐แแณแฐแฅแซ ...
.
โก๏ธแแฉแ แแญ แแแแแ แจ แฎแแตแตแซแญแฝแ แแณแฎแฝ แแช แแแ แ แ แแแ แ แญแแแตแ!
.
๐ฉแแแแแแ แแณแฅ แฅแ แ แตแฐแซแจแต @ETCONpBOT แแแแแข แฅแแแฐแแแแ๐
โThis is discussion group of @ETCONpWORK
.
๐แแณแฐแฅแซ ...
.
โก๏ธแแฉแ แแญ แแแแแ แจ แฎแแตแตแซแญแฝแ แแณแฎแฝ แแช แแแ แ แ แแแ แ แญแแแตแ!
.
๐ฉแแแแแแ แแณแฅ แฅแ แ แตแฐแซแจแต @ETCONpBOT แแแแแข แฅแแแฐแแแแ๐
๐CONSTRUCTION ENGINEERING TIPS @COTMp
.
*ASTM Abbrevation : American Society for Testing Materials
*Grade of Concrete is denoted as Cement: Sand: Aggregate (Ex C-20 Grade : 1:2:3)
*C/C means Center to Center Distance
*DL means Development Length
*Lapping of bars not allowed if the dia of bar is more than 36mm.
*For circular column minimum of 6 longitudinal bars are used and 4 for Rectangular.
*The minimum thickness of slab is 0.125m
*Water pH value less than 6 should not be used for construction purpose.
*The concrete Should not be thrown from a height more than 1.5m.
*The Compressive strength of Bricks is 3.5 N /mm
*The initial setting time shall not be less than 30 minutes and the final setting time of cement is 10hours.
*Dead Load means Self weight of Structure
*Sand having moisture content more than 5% should not be used for Concrete mix.
*DPC means Damp Proof Course. The thickness of DPC should not be less than 2.5cm.
*Cube test is carried out for each 30m usage of concrete.
*RMC : Ready Mix concrete, The concrete is made at factory and transported to the site, This type of concrete is used where there is a lack of space for mixing the concrete and used where a huge amount of concrete is required for construction.
*The height of floor is usually 3m or 10ft (If a person asks you whats the height of 12 storied building?
Ans: 3m x 12floors = 36m)
*A head mason can work 25-30m in a day.
*In construction, the rate analysis for the work of workers is calculated in Man Hours. (Ex: 10 Birr for 1 Man hour)
*Cantilever Beam has One fixed support and the other end is free.
*Simple supported beam has a minimum of two supports.
*PCC (Plain Cement Concrete) this type of concrete is used on members only when the tensile forces are not acting on it.
*The weight of first class clay brick should be 3.85 Kg. and it has a crushing
strength of 10.5MN/m
*Adding more water in the concrete mix to increase setting time leads to form
the Cracks or honeycomb in hardened concrete.
*Vibration in freshly made concrete is done to remove the air bubbles in concrete mix.
*Impermeability of concrete: The concrete which resists the the entry of water or moisture into it.
*The concrete can be lifted to a maximum height of 50m using Concrete
Pumps.
*The curing Period of RCC is 28days .
*The minimum sill level height should be
44 inches.
*The transverse reinforcement provided in columns are called Ties .
*The transverse reinforcement provided in
Beams is called as Stirrups .
*Stirrups in Beams and Ties in Column are provided to handle the shear force and to keep longitudinal bars in position.
*The Prime reason for using steel as reinforcement is due to thermal expansion.
The thermal expansion
coefficient of concrete and steel is (approximately) same having value
*C-25 grade of concrete is generally used in the construction of slab.
*Weight of Bar is calculated using formula D /162 (D = Dia of bar in mm)
*The No. of HCB required for 1 metr square of masonary wall are 13 HCB blocks.
*Specific gravity of Cement is 3.16g/ cm ; Bricks is 2g/cm ; Sand is 2.65g/cm ,
*Standard Size of Brick is 19cm x 9cm x 4 cm or 19cm or 9cm x 9 cm
*Floor area occupied by 50kg of Cement bag is 0.3m and height of 0.18m.
*As per EBCS Maximum dia of bar used in the slab should not exceed 1/8th of the total thickness of the slab.
*The slope or Pitch of the stair should be in between 25 degrees to 40 degrees.
*The rise in stairs is in between 150mm to 200mm.
*Tread in staircase is in between 250mm to 300mm.
*Hook length should not be less than 9D (Dia of Bar)
*Unit weight of PCC is 24KN/m , RCC is 25 KN/m , Steel is 7850Kg/m
*The volume of 50kg cement bag is
1.3CFT.
*Theodolite least count is 20Secs whereas Compass Least count is 30mins .
*TMT bars : TMT means Thermo Mechanically treated bars
*Cement more than 3 months old cannot be used for construction
*The length of each bar from factory is 12m.
.
๐แแฐแจแแช แจ แฎแแตแตแซแญแฝแ แตแแ แญแถแฝ ๐ฉ แฅแแ แญแซแ
๐๐๐๐๐
https://telegram.me/COTMp
โถแผแญ แผแญ แผแญ
.
*ASTM Abbrevation : American Society for Testing Materials
*Grade of Concrete is denoted as Cement: Sand: Aggregate (Ex C-20 Grade : 1:2:3)
*C/C means Center to Center Distance
*DL means Development Length
*Lapping of bars not allowed if the dia of bar is more than 36mm.
*For circular column minimum of 6 longitudinal bars are used and 4 for Rectangular.
*The minimum thickness of slab is 0.125m
*Water pH value less than 6 should not be used for construction purpose.
*The concrete Should not be thrown from a height more than 1.5m.
*The Compressive strength of Bricks is 3.5 N /mm
*The initial setting time shall not be less than 30 minutes and the final setting time of cement is 10hours.
*Dead Load means Self weight of Structure
*Sand having moisture content more than 5% should not be used for Concrete mix.
*DPC means Damp Proof Course. The thickness of DPC should not be less than 2.5cm.
*Cube test is carried out for each 30m usage of concrete.
*RMC : Ready Mix concrete, The concrete is made at factory and transported to the site, This type of concrete is used where there is a lack of space for mixing the concrete and used where a huge amount of concrete is required for construction.
*The height of floor is usually 3m or 10ft (If a person asks you whats the height of 12 storied building?
Ans: 3m x 12floors = 36m)
*A head mason can work 25-30m in a day.
*In construction, the rate analysis for the work of workers is calculated in Man Hours. (Ex: 10 Birr for 1 Man hour)
*Cantilever Beam has One fixed support and the other end is free.
*Simple supported beam has a minimum of two supports.
*PCC (Plain Cement Concrete) this type of concrete is used on members only when the tensile forces are not acting on it.
*The weight of first class clay brick should be 3.85 Kg. and it has a crushing
strength of 10.5MN/m
*Adding more water in the concrete mix to increase setting time leads to form
the Cracks or honeycomb in hardened concrete.
*Vibration in freshly made concrete is done to remove the air bubbles in concrete mix.
*Impermeability of concrete: The concrete which resists the the entry of water or moisture into it.
*The concrete can be lifted to a maximum height of 50m using Concrete
Pumps.
*The curing Period of RCC is 28days .
*The minimum sill level height should be
44 inches.
*The transverse reinforcement provided in columns are called Ties .
*The transverse reinforcement provided in
Beams is called as Stirrups .
*Stirrups in Beams and Ties in Column are provided to handle the shear force and to keep longitudinal bars in position.
*The Prime reason for using steel as reinforcement is due to thermal expansion.
The thermal expansion
coefficient of concrete and steel is (approximately) same having value
*C-25 grade of concrete is generally used in the construction of slab.
*Weight of Bar is calculated using formula D /162 (D = Dia of bar in mm)
*The No. of HCB required for 1 metr square of masonary wall are 13 HCB blocks.
*Specific gravity of Cement is 3.16g/ cm ; Bricks is 2g/cm ; Sand is 2.65g/cm ,
*Standard Size of Brick is 19cm x 9cm x 4 cm or 19cm or 9cm x 9 cm
*Floor area occupied by 50kg of Cement bag is 0.3m and height of 0.18m.
*As per EBCS Maximum dia of bar used in the slab should not exceed 1/8th of the total thickness of the slab.
*The slope or Pitch of the stair should be in between 25 degrees to 40 degrees.
*The rise in stairs is in between 150mm to 200mm.
*Tread in staircase is in between 250mm to 300mm.
*Hook length should not be less than 9D (Dia of Bar)
*Unit weight of PCC is 24KN/m , RCC is 25 KN/m , Steel is 7850Kg/m
*The volume of 50kg cement bag is
1.3CFT.
*Theodolite least count is 20Secs whereas Compass Least count is 30mins .
*TMT bars : TMT means Thermo Mechanically treated bars
*Cement more than 3 months old cannot be used for construction
*The length of each bar from factory is 12m.
.
๐แแฐแจแแช แจ แฎแแตแตแซแญแฝแ แตแแ แญแถแฝ ๐ฉ แฅแแ แญแซแ
๐๐๐๐๐
https://telegram.me/COTMp
โถแผแญ แผแญ แผแญ
Telegram
ETCONp Discussion
โ๏ธแญแ
แจ @etconp แแแซแซ แแฉแแน แแแข
โThis is discussion group of @ETCONpWORK
.
๐แแณแฐแฅแซ ...
.
โก๏ธแแฉแ แแญ แแแแแ แจ แฎแแตแตแซแญแฝแ แแณแฎแฝ แแช แแแ แ แ แแแ แ แญแแแตแ!
.
๐ฉแแแแแแ แแณแฅ แฅแ แ แตแฐแซแจแต @ETCONpBOT แแแแแข แฅแแแฐแแแแ๐
โThis is discussion group of @ETCONpWORK
.
๐แแณแฐแฅแซ ...
.
โก๏ธแแฉแ แแญ แแแแแ แจ แฎแแตแตแซแญแฝแ แแณแฎแฝ แแช แแแ แ แ แแแ แ แญแแแตแ!
.
๐ฉแแแแแแ แแณแฅ แฅแ แ แตแฐแซแจแต @ETCONpBOT แแแแแข แฅแแแฐแแแแ๐
๐PROPERTIES OF AGGREGATES FOR CONCRETE @COTMp
.
โถApproximately 75% of the volume of concrete is occupied by aggregates,so
quality of aggregates plays an important role in determining properties of concrete.
*Aggregates come in various shapes, sizes, and materials ranging from fine particles of sand to large, coarse rocks. *Natural aggregates are formed by process of weathering and abrasion or by artificially crushing large parent mass.
Because cement is the most expensive ingredient in making concrete, it is
desirable to minimize the amount of cement used. 70 to 80% of the volume of
concrete is aggregate in order to keep the cost of the concrete low.
*Soft, porous aggregates can result in weak concrete with low wear resistance, while using hard aggregates can make strong concrete with a high resistance to abrasion.
*Aggregates are of two basic types: Coarse: crushed rock, gravel or screenings.
*Fine: fine and coarse sands and crusher fines Aggregates should be clean, hard, and strong.
*The aggregate is usually washed to remove any dust, silt, clay, organic matter, or other impurities that would interfere with
the bonding reaction with the cement paste.
*The choice of aggregate is determined by the proposed use of the concrete.
*Normally sand, gravel, and crushed stone are used as aggregates to make concrete.
*The aggregate should be well-graded to improve packing efficiency and minimize the amount of cement paste needed. Also, this makes the concrete more workable.
Some of the important properties of aggregates are discussed below.
โถPROPERTIES OF AGGREGATES
1. SOUNDNESS:Rocks that undergo volume changes due to wetting and drying are rare. However, aggregate is susceptible to volume change during freezing and thawing cycles.
*Freezing can cause internal stresses to build up as water inside the aggregate freezes and expands.
2. WEAR RESISTANCE
A good aggregate will be hard, dense, strong, and
free of porous material. The abrasion resistance of
aggregate can be tested by the Los Angeles abrasion test; however, this test does not match
well with concrete wear in the field.
3. ALKALI-AGGREGATE
REACTION: An expansive reaction between some reactive forms of silica with the aggregate and alkalis in the cement paste.
*The result is overall cracking in the
structure, manifesting itself in map or pattern cracking at the surface. *This reaction can be
controlled most easily by using low-alkali cements.
However, due to changes in manufacturing, low-
alkali cements may not be feasible.
*A better approach is to avoid aggregate with the potential or proven record of reactivity. A low w/c ratio is very impermeable and will slow down the reaction but not stop it. No adverse reactions will occur without external water.
4. OTHER ALKALI-SILICA
REACTIONS: Sand-gravels found in river systems of Kansas and Nebraska are highly reactive and cause map cracking. *Replacement of 30% of the aggregate with
crushed limestone is effective in reducing the damage. Basically, it results in the separation of flat clay minerals causing very slow expansion.
5. ALKALI-CARBONATE REACTIONS: An expansive reaction involving clayey
carbonate rock. Reaction can be controlled by using low-alkali cements or blending aggregate with other less reactive material.
*ASTM has set standards for deleterious substances in aggregates, which depend on application.
6. IMPURITIES: Solid materials โ particles passing a 200- mesh sieve.
*These fine particles may increase water requirements and interfere with surface bonding
between cement and coarse aggregates.
Soluble substances โorganic matter may interfere chemically with alkaline cement pastes affecting setting time. *Aggregates obtained from the sea should be thoroughly cleaned
to avoid problems from salt contamination.
7. UNSOUND PARTICLES
Soft particles such as clay lumps, wood, and coal
will cause pitting and scaling at the surface.
Organic compounds can be released which interfere
with setting and hardening. Weak material of low density which have low wear resistance should also be avoided.
https://telegram.me/COTMp
.
โถApproximately 75% of the volume of concrete is occupied by aggregates,so
quality of aggregates plays an important role in determining properties of concrete.
*Aggregates come in various shapes, sizes, and materials ranging from fine particles of sand to large, coarse rocks. *Natural aggregates are formed by process of weathering and abrasion or by artificially crushing large parent mass.
Because cement is the most expensive ingredient in making concrete, it is
desirable to minimize the amount of cement used. 70 to 80% of the volume of
concrete is aggregate in order to keep the cost of the concrete low.
*Soft, porous aggregates can result in weak concrete with low wear resistance, while using hard aggregates can make strong concrete with a high resistance to abrasion.
*Aggregates are of two basic types: Coarse: crushed rock, gravel or screenings.
*Fine: fine and coarse sands and crusher fines Aggregates should be clean, hard, and strong.
*The aggregate is usually washed to remove any dust, silt, clay, organic matter, or other impurities that would interfere with
the bonding reaction with the cement paste.
*The choice of aggregate is determined by the proposed use of the concrete.
*Normally sand, gravel, and crushed stone are used as aggregates to make concrete.
*The aggregate should be well-graded to improve packing efficiency and minimize the amount of cement paste needed. Also, this makes the concrete more workable.
Some of the important properties of aggregates are discussed below.
โถPROPERTIES OF AGGREGATES
1. SOUNDNESS:Rocks that undergo volume changes due to wetting and drying are rare. However, aggregate is susceptible to volume change during freezing and thawing cycles.
*Freezing can cause internal stresses to build up as water inside the aggregate freezes and expands.
2. WEAR RESISTANCE
A good aggregate will be hard, dense, strong, and
free of porous material. The abrasion resistance of
aggregate can be tested by the Los Angeles abrasion test; however, this test does not match
well with concrete wear in the field.
3. ALKALI-AGGREGATE
REACTION: An expansive reaction between some reactive forms of silica with the aggregate and alkalis in the cement paste.
*The result is overall cracking in the
structure, manifesting itself in map or pattern cracking at the surface. *This reaction can be
controlled most easily by using low-alkali cements.
However, due to changes in manufacturing, low-
alkali cements may not be feasible.
*A better approach is to avoid aggregate with the potential or proven record of reactivity. A low w/c ratio is very impermeable and will slow down the reaction but not stop it. No adverse reactions will occur without external water.
4. OTHER ALKALI-SILICA
REACTIONS: Sand-gravels found in river systems of Kansas and Nebraska are highly reactive and cause map cracking. *Replacement of 30% of the aggregate with
crushed limestone is effective in reducing the damage. Basically, it results in the separation of flat clay minerals causing very slow expansion.
5. ALKALI-CARBONATE REACTIONS: An expansive reaction involving clayey
carbonate rock. Reaction can be controlled by using low-alkali cements or blending aggregate with other less reactive material.
*ASTM has set standards for deleterious substances in aggregates, which depend on application.
6. IMPURITIES: Solid materials โ particles passing a 200- mesh sieve.
*These fine particles may increase water requirements and interfere with surface bonding
between cement and coarse aggregates.
Soluble substances โorganic matter may interfere chemically with alkaline cement pastes affecting setting time. *Aggregates obtained from the sea should be thoroughly cleaned
to avoid problems from salt contamination.
7. UNSOUND PARTICLES
Soft particles such as clay lumps, wood, and coal
will cause pitting and scaling at the surface.
Organic compounds can be released which interfere
with setting and hardening. Weak material of low density which have low wear resistance should also be avoided.
https://telegram.me/COTMp
Telegram
ETCONp Discussion
โ๏ธแญแ
แจ @etconp แแแซแซ แแฉแแน แแแข
โThis is discussion group of @ETCONpWORK
.
๐แแณแฐแฅแซ ...
.
โก๏ธแแฉแ แแญ แแแแแ แจ แฎแแตแตแซแญแฝแ แแณแฎแฝ แแช แแแ แ แ แแแ แ แญแแแตแ!
.
๐ฉแแแแแแ แแณแฅ แฅแ แ แตแฐแซแจแต @ETCONpBOT แแแแแข แฅแแแฐแแแแ๐
โThis is discussion group of @ETCONpWORK
.
๐แแณแฐแฅแซ ...
.
โก๏ธแแฉแ แแญ แแแแแ แจ แฎแแตแตแซแญแฝแ แแณแฎแฝ แแช แแแ แ แ แแแ แ แญแแแตแ!
.
๐ฉแแแแแแ แแณแฅ แฅแ แ แตแฐแซแจแต @ETCONpBOT แแแแแข แฅแแแฐแแแแ๐
๐Today Book Tip @COTMp
.
โถแ แ แจแแฝแแ แแฐแจแต แจแฐแแจแก แแญแฅ แแ แแแถแฝ แญแแโ
.
โกแ แแแ Join แ แแจแ แฅแ แแแฐแแ แฅแ แแแซแแต แแ แผแญ แซแตแญแแข๐๐๐
.
โถแ แ แจแแฝแแ แแฐแจแต แจแฐแแจแก แแญแฅ แแ แแแถแฝ แญแแโ
.
โกแ แแแ Join แ แแจแ แฅแ แแแฐแแ แฅแ แแแซแแต แแ แผแญ แซแตแญแแข๐๐๐
Willisโs Elements of Quantity Surveying.pdf
8.8 MB
๐ Book Tip @COTMp
Structural_Analysis_and_Design_of.pdf
79.7 MB
๐ Book Tip @COTMp
Structural_Analysis_by_R_C_Hibbeler.pdf
30.1 MB
๐ Book Tip @COTMp