Ethio Construction Engineering
32.4K subscribers
6.23K photos
359 videos
1.99K files
3.21K links
🔨 World Construction Engineering
Latest updates, tips, and tutorials on building, civil engineering, and construction in World.
Learn, build, and grow with us!

📨 @Philemona7 Or @ETCONpBOT

For Ad:- https://telega.io/c/etconp
Download Telegram
👉Do You Have Problem at Road Estimation?

🚧Project Details:

⏺Length of Road: 1,000 meters

⏺Width of Road: 7 meters

⏺Thickness of Asphalt Layer: 0.10 meters (10 cm)

🏷1. Road Area Calculation:
Area = Length × Width = 1000 m × 7 m = 7000 m²

🏷2. Volume of Asphalt:
Volume = Area × Thickness = 7000 m² × 0.10 m = 700 m³

🏷3. Conversion to Tons (Density of Asphalt ≈ 2.4 ton/m³): Total Asphalt = 700 m³ × 2.4 ton/m³ = 1680 tons

🏷4. Material Cost Estimation (example rates):

📍Asphalt per ton: $85

🎲Total Cost = 1680 tons × $85 = $142,800

🏷5. Additional Costs (Example):

⏺Transportation: $5,000

⏺Labor: $8,000

⏺Equipment Rental: $10,000

⏺Miscellaneous (5%): $7,140

🚧6. Total Estimated Cost:

⏺Material Cost = $142,800
⏺Transportation = $5,000
⏺Labor = $8,000
⏺Equipment Rental = $10,000
⏺Miscellaneous (5%) = $7,140
--------------------------------
❇️Grand Total 9= $172,940


@etconp
👍21❤13🥰1
👉 INTERCON Construction Chemicals 

● Concrete Admixtures
● Bonding Agents
● Waterproofings
● Wall Putty, Prime Coat
● Concrete Repair Mortar
● Floor hardener, Epoxy
● Grout, Self-level mortar
● Quartz paint, Contextra
● Tile Adhesive & Tile Joint Fillers 
● Geotextiles and other construction chemicals and materials

☎️ Tel: 0961955555

🔹 Address 1: Signal road, around
Dinberwa Hospital

🔹 Addres 2: Wellosefer, Infront of
Dani Plaza
❤5
Lateral supports in masonry walls are provided to prevent:
Anonymous Quiz
21%
A) Vertical cracks
54%
B) Sliding
21%
C) Buckling due to slenderness
4%
D) Creep
👍9
. Which type of paint is most resistant to moisture and humidity, often used in bathrooms?
Anonymous Quiz
11%
A) Matte paint
30%
B) Acrylic paint
53%
C) Epoxy paint
5%
D) Distemper
❤8
Which type of paint finish is most durable and easy to clean for interior walls?
Anonymous Quiz
13%
A) Matte finish
14%
B) Satin finish
38%
C) Glossy finish
36%
D) Flat finish
❤6
1)In route survey, the most suitable method of
contouring is-
Anonymous Quiz
19%
(a) by squares
38%
(b) by radial lines
16%
(c) by c/s
27%
(d) by tachometry
❤8
2)Minimum diameter of the lateral ties should
not be less than
Anonymous Quiz
27%
(a) 10 mm
51%
(b) 6 mm
13%
(c) 5 mm
9%
(d) 4 mm
👍3🎉3❤1
🙏3❤2👍2👏1
Workability of concrete depends on:
Anonymous Quiz
42%
Water to cement ratio
8%
Amount of water
48%
Both
2%
None of the abobe
👍6🔥2
Which characteristic does not necessarily describe a deformation in the elastic region?
Anonymous Quiz
13%
reversible
35%
molecular bonds have no slip
19%
temporary
33%
Stress/ Strain slope is constant
❤5👏3
👉What Do You Think The Cause Of The Failure

@etconp
❤1👏1
Ethio Construction Engineering
👉What Do You Think The Cause Of The Failure @etconp
👉The failure of the concrete staircase is primarily caused by 
improper or insufficient steel reinforcement and poor structural design and execution at the connection point with the upper floor slab. 

🚧Details of the Failure

💫Lack of Proper Anchorag:

⏺The image and associated information indicate a critical mistake where the main reinforcement bars of the staircase were not properly anchored into the landing beam or slab above with adequate development length or proper bends (hooks). Instead, they appear to have been cut short or installed incorrectly.

💫Missing or Incorrect Negative Reinforcement:

⏺The diagrams in the image highlight the need for "top" or negative reinforcement bars extending from the top of the stair into the upper slab to handle the tension forces that occur at this connection point when the stair is loaded.
This was likely omitted or installed incorrectly in the failed structure.

💫Structural Weakness:

⏺A staircase is a major structural element that carries significant loads.
⏺Without correct and continuous reinforcement into the supporting structure, the connection point becomes a weak link, leading to a bond failure and collapse as seen in the image.

💫Substandard Workmanship:

⏺This type of failure often results from trying to cut costs, using unqualified labor, or failing to follow approved engineering drawings and building codes. 

@etconp
❤8👍3👏1
👉 INTERCON Construction Chemicals 

● Concrete Admixtures
● Bonding Agents
● Waterproofings
● Wall Putty, Prime Coat
● Concrete Repair Mortar
● Floor hardener, Epoxy
● Grout, Self-level mortar
● Quartz paint, Contextra
● Tile Adhesive & Tile Joint Fillers 
● Geotextiles and other construction chemicals and materials

☎️ Tel: 0961955555

🔹 Address 1: Signal road, around
Dinberwa Hospital

🔹 Addres 2: Wellosefer, Infront of
Dani Plaza
❤1