The accumulation of water on the outer surface of concrete is called:
Anonymous Quiz
28%
Curing
60%
Bleeding
9%
Absorption
3%
Hardening
πŸ‘3
In the slope deflection equations, the
deformations are considered to be caused by
Anonymous Quiz
15%
a) Shear force
36%
(b) Bending moment
18%
(c) Axial force
32%
(d) Bending moment and shear force both
πŸ‘4❀2
A fixed beam settles at one end by Ξ΄, if EI is the
flexural rigidity of the beam, the fixed end
moments at the ends be
Anonymous Quiz
25%
(a) EI Ξ΄/L2
31%
(b) 2EI Ξ΄/L2
28%
(c) 4EI Ξ΄/L2
16%
(d) 6EI Ξ΄/L2
πŸ™4❀2
πŸ™11❀1
Conjugate beam of an indeterminate structure
will be
Anonymous Quiz
25%
(a) Unstable
43%
(b) Indeterminate
26%
(c) Stable
5%
(d) Can't say
πŸ‘Œ6❀5πŸ•Š1
β€œThe deflection of a point in the real beam is
numerically equal to the bending moment at
the corresponding point in the conjugate beam”. This theorem is used for analysis of beams in which of the following methods?
Anonymous Quiz
13%
(a) Castigliano's method
32%
(b) Moment area method
51%
(c) Conjugate beam method
4%
(d) None of the above
πŸ‘6❀2
The principle of virtual work is applied to elastic
system by considering virtual work done by
Anonymous Quiz
19%
(a) Internal forces only
19%
(b) External forces only
58%
(c) Internal as well as external forces
4%
(d) None of the above
πŸ‘1
In reinforced concrete construction, the
structures in which marked changes in plane
dimension take place abruptly shall be provided with :
Anonymous Quiz
15%
(a) contraction joints
16%
(b) vertical cut
35%
(c) construction joints
34%
(d) expansion joints
❀6
In reinforced cement concrete construction; lap
splices are not recommended to be used for
rebars when the bar diameter is more than :
Anonymous Quiz
43%
(a) 32 mm
13%
(b) 30 mm
29%
(c) 36 mm
15%
(d) 25 m
❀6πŸ‘2
Effective moment of inertia for short term
deflection of a reinforced concrete section does
not depend on–
Anonymous Quiz
20%
(a) the maximum moment under the service load
21%
(c) breadth of the compression face
35%
(d) ultimate shrinkage strain of concrete.
24%
(b) depth of the neutral axis
πŸ™5❀1
At the time of bending of a beam, a layer is
neither elongated nor contracted is.
Anonymous Quiz
16%
(a) Axis of symmetry
62%
(b) Neutral axis
13%
(c) Axis of moment
9%
(d) Axis of load
πŸ™4❀2
The additional cover thickness to be provided
in reinforced concrete member that are total
immersed in sea water is :
Anonymous Quiz
28%
(a) 25 mm
12%
(b) 30 mm
10%
(c) 35 mm
50%
(d) 40 mm
❀3πŸŽ‰3
πŸ‘‰ INTERCON Construction Chemicals 

● Concrete Admixtures
● Bonding Agents
● Waterproofings
● Wall Putty, Prime Coat
● Concrete Repair Mortar
● Floor hardener, Epoxy
● Grout, Self-level mortar
● Quartz paint, Contextra
● Tile Adhesive & Tile Joint Fillers 
● Geotextiles and other construction chemicals and materials

☎️ Tel: 0961955555

πŸ”Ή Address 1: Signal road, around
      Dinberwa Hospital

πŸ”Ή Addres 2: Wellosefer, Infront of
     Dani Plaza
ADVERTISMENT

α‰³αˆαˆ«α‰΅ α•αˆŒα‰΅ αŠ₯αŠ“ αŒ„ α‰¦αˆα‰΅ αŠ α‰…αˆ«α‰’

βœ…α‹¨αˆαŠ•αˆ°αŒ£α‰Έα‹ αŠ αŒˆαˆαŒαˆŽα‰Άα‰½

πŸ”… α•αˆŒα‰΅ any Size & thickness
πŸ”… αŒ„ α‰¦αˆα‰΅ (αŒ₯ርሡ αˆ›α‹‰αŒ£α‰΅αŠ“ αˆ›αŒ α)

πŸ”… α‹¨α‰°αˆˆα‹«α‹©  [modefic] αˆ΅αˆ«α‹Žα‰½αŠ• αŠ₯αŠ•αˆ°αˆ«αˆˆαŠ•α’

♦️ αˆ›αŠ•αŠ›α‹‰αŠ•αˆ α‰₯αˆ¨α‰³ α‰₯αˆ¨α‰΅ αŠ₯αŠ•αŒˆα‹›αˆˆαŠ•α’

☎️ሡልክ 0904040477 α‹ˆα‹­αˆ 0911016833 α‹°α‹αˆˆα‹ α‹«αŒαŠ™αŠ•
πŸ“±α‰΄αˆŒαŒαˆ«αˆ αˆ‹α‹­ ፦https://t.me/heavenic1

αŠ α‹΅αˆ«αˆ»α¦  ቁ 1.αˆ˜αˆ­αŠ«α‰Ά
                ቁ.2 αŠ α‹¨αˆ­ αŒ€αŠ“  αŠͺα‹³αŠ αˆαˆ…αˆ¨α‰΅

αŒ₯αˆ«α‰΅αŠ“ α‰³αˆ›αŠαŠα‰΅ αˆ˜αˆˆα‹«α‰½αŠ• αŠα‹α’
α‰³αˆαˆ«α‰΅ α•αˆŒα‰΅ αŠ₯αŠ“ αŒ„ α‰¦αˆα‰΅ αŠ α‰…αˆ«α‰’
❀1πŸ‘Œ1
πŸ‘‰HOLLOW CONCRETE BLOCK (HCB) – CLASS B LABORATORY TESTS

πŸ’«Class B Hollow Concrete Blocks are used for non-load bearing walls or medium-strength construction.

🚧To certify quality, the following laboratory tests are performed.

βœ… 1. Compressive Strength Test

⏺Standard: ASTM C140
Purpose: To measure block strength.

❇️Typical Requirement for Class B HCB:

Minimum compressive strength: 3.5 MPa to 5.0 MPa (varies with project spec)

Test 3 blocks (average value)

βœ… 2. Dimension & Shape Tolerance

Standard: ASTM C140 / ES Standard
Purpose: Check if the block meets size and shape requirements.

Requirements (typical):

Length, width, height within Β±3 mm tolerance

Faces should be flat and perpendicular

No large cracks or visible defects

βœ… 3. Density Test (Dry Density)

Purpose: Confirm block classification (lightweight, medium, or normal).

Typical values:

1400 – 1700 kg/mΒ³ for Class B HCB

βœ… 4. Water Absorption

Standard: ASTM C140
Requirement:

Water absorption ≀ 12–15%

High absorption indicates weak block quality.

βœ… 5. Block Weight Measurement

Purpose: Ensure consistency and structural performance.

Values depend on block size (e.g., 150 mm, 200 mm thickness).

βœ…Optional Tests (if required)

Ultrasound pulse velocity test – for uniformity

Efflorescence test – check salt content

Moisture content

πŸ“Œ Summary Table for Easy Use

Test Purpose Typical Requirement (Class B)

Compressive Strength Strength β‰₯ 3.5 – 5.0 MPa
Dimensions Size accuracy Β± 3 mm tolerance
Density Quality classification 1400–1700 kg/mΒ³
Water Absorption Durability ≀ 12–15%
Weight Consistency As per design block type

@etconp
❀15
πŸ‘‰THE CHEMISTRY OF A CONCRETE MIX

πŸ’«When you combine Cement + Water + Aggregates + (Admixtures) a set of chemical reactions begin automatically.

🚧The most important chemical process is hydration β€” the reaction between cement and water.

🏷1. Chemistry of Cement

Cement is mainly made of four compounds:

*Tricalcium Silicate , C₃S for Early strength + heat
*Dicalcium Silicate, Cβ‚‚S for Later strength
*Tricalcium Aluminate, C₃A to Controls setting (fast reaction)
*Tetracalcium Aluminoferrite,  Cβ‚„AF for Minor strength

Gypsum (CaSOβ‚„Β·2Hβ‚‚O) is added to control setting time.

🏷2. When water is added β†’ Hydration begins

Water reacts with cement compounds to form new materials that make the concrete hard and strong.

🧬 A. Main Reaction: Formation of C–S–H Gel

C₃S + Water β†’ C–S–H (Calcium Silicate Hydrate) + Ca(OH)β‚‚

C–S–H gel is the glue that binds everything

Gives strength + durability

Forms 50–60% of the final hardened concrete

Cβ‚‚S reacts slower:

Cβ‚‚S + Water β†’ C–S–H + Less Ca(OH)β‚‚

This provides long-term strength.

🧬 B. Formation of Ettringite (Setting Control)

C₃A reacts extremely fast, so gypsum controls the reaction:

C₃A + Gypsum + Water β†’ Ettringite

Ettringite crystals cause initial setting (stiffening).

If gypsum is finished, ettringite converts to monosulfate:

Ettringite β†’ Monosulfate

🧬 C. Reaction of Cβ‚„AF

Produces ferrite hydrates that help setting but add little strength.

🏷3. Chemistry of Aggregates

Aggregates do not react much chemically.
Their main role is:

*Fill space
*Provide bulk
*Reduce cement content
*Improve strength by interlocking

But their surface bonds chemically with the C–S–H gel.

🏷4. Water–Cement Ratio (w/c) Chemistry

Lower water = denser hydration products.

Low w/c β†’ more C–S–H, higher strength

High w/c β†’ more pores, weaker concrete


🏷5. Chemistry of Admixtures
Admixtures modify hydration:

*Plasticizers / Superplasticizers

Disperse cement particles

Reduce water demand

Delay or accelerate hydration based on type

*Retarders
Slow down C₃A + C₃S reaction

*Accelerators
Speed up early hydration

🏷6. Chemistry Timeline of Concrete Hydration

*0–2 Hours: Initial setting

-C₃A + Gypsum β†’ Ettringite
-Early C₃S reaction begins

*2–10 Hours: Final setting

-Needle-like crystals lock particles
-Concrete becomes solid

*1–7 Days: Early Strength

-Rapid C–S–H growth from C₃S

*7–28 Days: Major Strength Gain

-Slow hydration of Cβ‚‚S
-Pore structure becomes tighter

*Months–Years: Long-term Hydration

-Continuous formation of C–S–H gel
-Increase in durability

πŸ“Œ In simple words:

⏺Concrete gets hard because cement reacts with water and forms glue (C–S–H gel) and crystals that bind sand and stone together.

@etconp
❀8πŸ‘2
πŸ‘‰Claim on Additional floor Construction/Addition Works/:

πŸ’«A contractor can generally claim for an additional floor construction requested by the client, but it depends on the contract agreement and the change management procedures in place.

🏷How it usually works?

🚧1. Check the Original Contract

If the signed contract was for G+8, and now the client wants to extend to G+10, this is outside the original scope.

The contractor is not obligated to do it without a variation order (VO) or new contract agreement.

🚧2. Variation / Change Order

Most contracts (FIDIC, PPA Ethiopia 2011, etc.) have clauses for variations.

The client (or Engineer/Consultant) issues a variation instruction in writing.

The contractor then submits a claim for:

Additional costs (materials, labor, equipment, subcontractors).

Time extension (because adding two floors increases duration).

🚧3. Contractor’s Right to Claim

The contractor can claim if:

The client formally instructs the change.

The change affects cost and time.

Contractor must submit the claim within the time frame stated in the contract (often 28 days in FIDIC).

🚧4. Evaluation and Approval

The Engineer/Consultant or Client evaluates the claim.

Once approved, the contract price and completion date are adjusted.

🚧5. Risks if No Formal Agreement

If the contractor builds extra floors without written approval, payment disputes may arise.

The client may later refuse to pay, claiming it was not properly instructed.

πŸ“œIn summary:

⏺The contractor has the right to claim for additional floor construction requested by the client, but it must go through the formal variation/change order process, with clear documentation of cost and time impact.

@etconp