3007. Biochemical Oxygen Demand (B.O.D.) of safe drinking water must be
Anonymous Quiz
44%
(a) Nil
33%
(b) 5
18%
(c) 10
5%
(d) 15
❤3👏2🎉2
3006. In slow sland filters, the turbidity of raw water can be removed only up to
Anonymous Quiz
29%
(a) 60 mg/litre
39%
(b) 75 mg/litre
23%
(c) 100 gm/litre
9%
(d) 150 mg/litre
❤4🔥1👏1
ታምራት  ፕሌት እና ጄቦልት አቅራቢ

📌ፕሌትና ጄቦልት በፈለጉት አይነት የተዘጋጀ አለን

♧ ሁሉን በአንድ ቦታ ለሁሉም ቅርብ

♧ ምስክራችን ስራችን

📍ኢትዮጵያ ዉስጥ የትም እንልክሎታለን

♧ ይደውሉልን ያማክሩን

0904040477
0911016833
❤2
👉Types of Soil

📌Soil is a natural material formed by the weathering of rocks and minerals.

⏺It is an important subject in civil engineering, agriculture, and geology. Based on particle size, composition, and engineering behavior, soil can be classified into different types.

1. Gravel Soil

Gravel soil consists of large-sized particles. It has good drainage capacity and high bearing strength. It is suitable for foundations and road construction.

2. Sand Soil

Sand soil contains medium-sized particles. It has good drainage but low water retention. It is commonly used in construction and concrete works.

3. Silt Soil

Silt soil has fine particles and feels smooth. It can retain water better than sand but has low strength when wet.

4. Clay Soil

Clay soil consists of very fine particles. It has high water retention capacity but poor drainage. It shows shrinkage and swelling behavior.

5. Loam Soil

Loam soil is a mixture of sand, silt, and clay. It has good fertility and moderate strength. It is ideal for agriculture.

6. Peat Soil

Peat soil contains a high amount of organic matter. It has low bearing capacity and is not suitable for heavy construction.

7. Chalk Soil

Chalk soil is alkaline in nature and contains calcium carbonate. It is free-draining but may lack nutrients.

8. Laterite Soil

Laterite soil is rich in iron and aluminum. It is commonly found in tropical regions and used in road works.

📌Understanding the types of soil is essential for safe and economical design in civil engineering projects.

@etconp
❤12👍8
👉Effective Length of a Column

💫Effective length (Le) of a column is the length between points of zero bending moment (contraflexure). It depends on the end support conditions, not only on the actual height.

Formula:
Le = K × L

Where:
L = actual unsupported length of column
K = effective length factor (depends on end conditions)

⭐️Effective Length Factors (K)

1. Both ends hinged (pinned–pinned)
K = 1.0
Le = L

2. One end fixed, other end free (cantilever)
K = 2.0
Le = 2L

3. One end fixed, other end hinged
K = 0.7
Le = 0.7L

4. Both ends fixed
K = 0.5
Le = 0.5L

🚧Importance of Effective Length

• Used to calculate slenderness ratio
• Helps predict buckling failure
• Important in RCC and steel column design

🏷Example

Actual column height = 3 m

Both ends hinged:
Le = 1.0 × 3 = 3 m

Both ends fixed:
Le = 0.5 × 3 = 1.5 m

@etconp
❤18🥰1
👉 INTERCON Construction Chemicals 

● Concrete Admixtures
● Bonding Agents
● Waterproofings
● Wall Putty, Prime Coat
● Concrete Repair Mortar
● Floor hardener, Epoxy
● Grout, Self-level mortar
● Quartz paint, Contextra
● Tile Adhesive & Tile Joint Fillers 
● Geotextiles and other construction chemicals and materials

☎️ Tel: 0961955555

🔹 Address 1: Signal road, around
      Dinberwa Hospital

🔹 Addres 2: Wellosefer, Infront of
     Dani Plaza
❤1
👉What Is a Cantilever Slab?

💫A cantilever slab is a reinforced concrete slab that is fixed (supported) at one end and extends freely at the other end without any support below.

📜In simple words:

⏺One side is held firmly by a beam, wall, or column, and the other side hangs out in the air.

🚧Key Characteristics

⏺Fixed support at one end only
⏺No column or wall support at the free end
⏺Carries load by bending action
⏺Top reinforcement is critical (tension occurs at the top)

🏷Where Cantilever Slabs Are Used

⏺Balconies
⏺Canopies and sunshades
Chajjas
⏺Projections in buildings
Stair landings

🔰Structural Behavior (Very Important)

⏺Top fibers:-Tension zone
⏺Bottom fibers:-Compression zone
❇️Steel bars are placed near the top surface
⏺Load is transferred back to the fixed support

🎲Advantages

⏺Provides architectural projection
⏺No need for columns below
Saves space
⏺Aesthetic appearance

📍Disadvantages

⏺Higher bending moment at support
⏺Requires careful design and detailing
⏺Deflection and cracking risk if poorly designed

⚡️Simple Example

⏺A balcony slab extending out from a building wall without any column beneath it is a cantilever slab.

@etconp
❤10👍7
👉What is a Septic Tank in a Building?

🚧A septic tank is an underground wastewater treatment system used in buildings that are not connected to a municipal sewer line.

⏺It safely collects, treats, and disposes of toilet waste, bathroom water, and kitchen wastewater.

🏷How a Septic Tank Works

⏺Wastewater enters the tank from the building through pipes.

⏺Solid waste settles at the bottom (called sludge).
⏺Oil and grease float on top (called scum).
⏺Liquid in the middle flows out to a soak pit or leach field, where it is absorbed into the soil.
⏺Bacteria inside the tank break down organic waste.

🏷Main Parts of a Septic Tank System

▶️Inlet pipe – carries wastewater from the building
▶️Septic tank chamber – separates solids and liquids
▶️Baffle or partition wall – controls flow and prevents blockage
▶️Outlet pipe – sends treated water to soak pit / leach field
▶️Soak pit (absorption pit) – allows water to safely seep into soil

⭐️Purpose of a Septic Tank

⏺Proper sanitation for buildings without sewer access
⏺Prevents environmental pollution
⏺Protects public health
Manages household wastewater safely

📍Where Septic Tanks Are Commonly Used

⏺Residential houses in rural or peri-urban areas
⏺Small apartments
⏺Schools, clinics, and offices outside sewer networks

⚡️Important Maintenance Notes

⏺Desludging is required every 2–5 years (depends on usage)
⏺Do not throw plastics, chemicals, or grease into toilets
⏺Proper design and construction are essential to avoid leakage

@etconp
👍7
Forwarded from Kelemat Ads
📚 አጠቃላይ የፋይናንስ እና የግብር Online ስልጠና!

🖥 ለመመዝገብ:

1️⃣ ወደ ድህረ-ገፃችን ይግቡ
👉 https://www.apextaxschool.com

2️⃣ “Join Now” የሚለውን ቁልፍ ይጫኑ

3️⃣ ሙሉ ስምዎን ኢሜልዎን እና Password ፈጥረው ያስገቡ

4️⃣ የሚፈልጉትን የስልጠና ክፍል ይምረጡ

5️⃣ “Enroll Now” በመጫን ከዝያም “Buy Now” በማለት ክፍያዎን ፈፅመው ምዝገባዎትን ያጠናቁ

በ0995958351 በመደወል መመዝገብም ይችላሉ።

📍 አድራሻ: ሃያ ሁለት፣ በየነ ጠበሉ ህንፃ፣ 1ኛ ፎቅ
📞 0995 958 351

#ApexFinancialSolution
#Onlinetraining
❤6
👉Dis Advantage Of Admixture

💫In concrete construction, admixtures are added to improve certain properties—but they also have disadvantages if not selected or used correctly.

🚧Main Disadvantages of Admixtures

🏷Increased Cost

⏺Admixtures raise the overall cost of concrete, especially for large projects.

🏷Wrong Dosage Problems

⏺Over-dosage or under-dosage can cause:
Excessive setting delay or rapid setting
Loss of strength
Segregation or bleeding

🏷Compatibility Issues
Some admixtures are not compatible with certain cement types, aggregates, or other admixtures, leading to unpredictable results.

🏷Reduction in Long-Term Strength (in some cases)
Certain admixtures (e.g., excessive retarders or air-entraining agents) can slightly reduce compressive strength if misused.

🏷Effect on Setting Time
Retarders may delay setting too much in cold weather
Accelerators may cause very fast setting in hot weather

🏷Durability Risks
Poor-quality or chloride-based admixtures can:
Increase risk of steel corrosion
Reduce durability of reinforced concrete

🏷Need for Skilled Control
Proper testing, mixing, and supervision are required. Without skilled control, results may be inconsistent.

🏷Workability Loss Over Time
Some plasticizers/superplasticizers lose effectiveness quickly (slump loss), especially in hot climates.

💫In Short

⏺Admixtures are beneficial but risky if misused.

⏺Correct selection, accurate dosage, and proper testing are essential to avoid negative effects.

@etconp
❤13👍3
ታምራት  ፕሌት እና ጄቦልት አቅራቢ

📌ፕሌትና ጄቦልት በፈለጉት አይነት የተዘጋጀ አለን

♧ ሁሉን በአንድ ቦታ ለሁሉም ቅርብ

♧ ምስክራችን ስራችን

📍ኢትዮጵያ ዉስጥ የትም እንልክሎታለን

♧ ይደውሉልን ያማክሩን

0904040477
0911016833
👉What Is Scaffolding in Building Construction?

💫Scaffolding is a temporary structure made of steel, aluminum, or timber that is erected around or inside a building to provide safe access and working platforms for workers during construction, repair, or maintenance activities at height.

🚧Purpose of Scaffolding in Building Construction

⏺1. Safe Working Platform
Provides a stable platform for workers to stand, sit, or place tools and materials.
Reduces the risk of falls and accidents when working at height.

⏺2. Access to High Areas
Enables workers to reach elevated parts of a building such as walls, columns, beams, and ceilings.
Essential for multi-storey buildings.

⏺3. Support for Construction Activities
Scaffolding is used during:
Brick and block masonry
Plastering and rendering
Painting and finishing works
Installation of windows, cladding, and services
Repair and maintenance work

⏺4. Material Handling
Allows safe storage of light materials (bricks, tools, paint buckets) near the work area.
Improves work efficiency and reduces movement time.

⏺5. Worker Safety
Fitted with guardrails, toe boards, and platforms to prevent falling.
❇️Helps comply with construction safety standards.

🏷Common Types of Scaffolding

⏺Single scaffolding – mainly for brickwork
⏺Double scaffolding – used in stone masonry
⏺Cantilever scaffolding – when ground support is not possible
⏺Suspended scaffolding – for painting and façade work
⏺Mobile scaffolding – movable type for light works

⭐️Simple Definition

Scaffolding is a temporary structure used in building construction to support workers and materials and to provide safe access to work at height.


@etconp
❤5👍2👏1🙏1
👉What is Formwork in Building Construction?

💫Formwork is a temporary or permanent mold used in construction to shape and support fresh concrete until it hardens and gains enough strength to support itself.

🔰In simple words, formwork is the container into which concrete is poured to get the required shape, size, and position of structural elements.

🚧Purpose of Formwork in Building Construction

⏺Formwork plays a very important role in concrete construction.

⭐️Its main purposes are:

🚧1. To Give Shape and Size

⏺Formwork ensures concrete members like slabs, beams, columns, walls, and foundations are formed according to the design drawings.

🚧2. To Support Fresh Concrete

⏺Fresh concrete is heavy and fluid. Formwork holds the concrete in place until it hardens and becomes strong enough.

🚧3. To Maintain Alignment and Level

⏺It keeps structural elements straight, level, and properly aligned, avoiding deformation.

🚧4. To Achieve Good Surface Finish

⏺Proper formwork provides a smooth and neat surface, reducing plastering and finishing work.

🚧5. To Ensure Safety During Construction

⏺Strong and well-fixed formwork prevents collapse, protecting workers and materials.

🏷Common Materials Used for Formwork

⏺Timber/Wood – most common and easy to use
Plywood – smooth finish, reusable

⏺Steel – strong, durable, reusable many times

⏺Aluminum – lightweight, fast construction

⏺Plastic – reusable and water-resistant

📍Where Formwork Is Used

⏺Columns
⏺Beams
⏺Slabs
⏺Foundations
⏺Staircases
⏺Shear walls

@etconp
❤6👍3
👉FIRST SAFETY

⚡️The first safety requirements on high-rise building construction are critical because work is done at great heights, with heavy materials, machinery, and many workers.

🚧These safety measures must be in place before and during construction to prevent serious accidents.

💫1. Site Safety Planning (Before Work Starts)
Prepare a Site Safety Plan (SSP)

⏺Conduct risk assessment for height work, lifting, fire, and electrical hazards
⏺Provide safety induction training for all workers
⏺Display safety signs, emergency contacts, and rules clearly on site

💫2. Personal Protective Equipment (PPE) – Mandatory

🏷Every worker must wear:

⏺Safety helmet (hard hat)
⏺High-visibility vest
⏺Safety boots (steel toe)
⏺Gloves
⏺Safety goggles
⏺Full body safety harness for work at height

💫3. Fall Protection Systems (Most Important)

⏺Guardrails at slab edges and openings
⏺Safety nets below work areas
⏺Lifelines and anchor points
Covered floor openings
⏺Strict rule: No work at height without fall protection

💫4. Scaffolding & Formwork Safety

⏺Scaffolding must be designed, erected, and inspected by competent persons
⏺Strong base and proper bracing
⏺Safe access ladders and platforms
⏺Formwork must be stable and checked before concreting

💫5. Lifting & Crane Safety

⏺Only certified crane operators
⏺Regular inspection of cranes, hoists, slings
⏺No lifting over workers
⏺Clear communication using signals or radios

💫6. Electrical Safety

⏺Proper grounding (earthing)
⏺Use insulated cables and tools
⏺Temporary power systems well protected
⏺No damaged wires or exposed connections

💫7. Fire Safety & Emergency Preparedness

⏺Fire extinguishers on every floor
⏺Safe storage of flammable materials
⏺Emergency evacuation routes
⏺First-aid kits and trained first-aiders
⏺Emergency drills

💫8. Housekeeping & Access Control

⏺Clean walkways and working areas
⏺Proper waste disposal
⏺Secure site fencing
⏺Restricted access for unauthorized persons

💫9. Safety Supervision & Monitoring

🎲Appoint a Safety Officer

⏺Daily safety inspections
⏺Toolbox meetings
⏺Immediate correction of unsafe acts

🔑 Key Rule:

Fall protection + PPE + supervision = life-saving combination in high-rise construction


@etconp
❤12👍9👏4🎉1
👉 INTERCON Construction Chemicals 

● Concrete Admixtures
● Bonding Agents
● Waterproofings
● Wall Putty, Prime Coat
● Concrete Repair Mortar
● Floor hardener, Epoxy
● Grout, Self-level mortar
● Quartz paint, Contextra
● Tile Adhesive & Tile Joint Fillers 
● Geotextiles and other construction chemicals and materials

☎️ Tel: 0961955555

🔹 Address 1: Signal road, around
      Dinberwa Hospital

🔹 Addres 2: Wellosefer, Infront of
     Dani Plaza
❤4👏2
Ethio Construction Engineering
👉Effective Length of a Column 💫Effective length (Le) of a column is the length between points of zero bending moment (contraflexure). It depends on the end support conditions, not only on the actual height. Formula: Le = K × L Where: L = actual unsupported…
👉Sections of Beam (Based on Reinforcement)

💫Reinforced concrete beams are classified into Balanced, Under-Reinforced, and Over-Reinforced sections based on the amount of steel provided.

🚧1) Balanced Section

▶️A balanced section is one in which both concrete and steel reach their permissible stresses at the same time.

• Concrete reaches its maximum compressive strain
• Steel just reaches its yield stress
• Neutral axis depth = critical depth

▶️Failure nature:

• Sudden and brittle

📜Remarks:

• Ideal theoretical condition
• Rarely used in practice due to lack of warning before failure

🚧2) Under-Reinforced Section

▶️An under-reinforced section has less steel than required for a balanced section.

• Steel yields first before concrete crushes
• Neutral axis depth < critical depth

📜Failure nature:

• Ductile failure
• Large deflection and visible cracks before failure

🎲Advantages:

• Gives sufficient warning before collapse
• Safe and preferred in design

🔰Used in practice:

• YES (most commonly used in RCC design)

🚧3) Over-Reinforced Section

▶️An over-reinforced section has more steel than required for a balanced section.

• Concrete crushes before steel yields
• Neutral axis depth > critical depth

📜Failure nature:

• Brittle failure
• Sudden collapse without warning

🎲Disadvantages:

• Unsafe
• Not recommended in RCC design

🔰Used in practice:

• NO (avoided by design codes)

📍Comparison Summary

❇️Balanced section:

• Steel and concrete fail together
• Brittle failure

❇️Under-reinforced section:

• Steel fails first
• Ductile and safe

❇️Over-reinforced section:

• Concrete fails first
• Brittle and unsafe

@etconp
❤7
👉Design Requirements for Solid Slab Design (Building Construction)

🚧A solid slab is a reinforced concrete slab that transfers loads directly to beams, walls, or columns.

💫To ensure safety, serviceability, and economy, the following requirements must be satisfied.

🏷1. Applicable Design Codes

⏺Design must comply with recognized standards, for example:
EBCS
ACI 318 (USA)
Eurocode 2 (EN 1992)
BS 8110
IS 456
Local building codes (as applicable)

🏷2. Span & Support Conditions

📍Identify whether the slab is one-way or two-way:

▶️One-way slab: Longer span / shorter span ≥ 2
▶️Two-way slab: Longer span / shorter span < 2

⏺Define support type: simply supported, continuous, or cantilever.

🏷3. Loads to Be Considered

⏺All relevant loads must be included:
❇️Dead load: Self-weight of slab + floor finishes
❇️Live load: Occupancy load (residential, office, storage, etc.)
❇️Partition wall load (if any)
Environmental loads: seismic and wind (indirect effect on slabs)
❇️Apply load combinations as per the code.

🏷4. Slab Thickness (Depth)

⏺Minimum thickness to control deflection:

⏺Simply supported slab:
h ≥ L / 20
🎲Continuous slab:
h ≥ L / 26
⏺Cantilever slab:
h ≥ L / 10
(L = effective span)
⏺Also check deflection limits according to code.

🏷5. Material Requirements

⏺Concrete grade: Usually ≥ C25/30
⚡️Reinforcement steel:
⏺Yield strength (fy) = 415 MPa or 500 MPa
⏺Materials must meet durability and exposure conditions.

🏷6. Reinforcement Design
Main reinforcement: Along the direction of bending

❇️Distribution reinforcement: Perpendicular to main bars
❇️Minimum reinforcement:
Typically ≥ 0.12% of gross concrete area (for HYSD bars)
❇️Bar spacing:
⏺Main bars ≤ 3d or 300 mm
⏺Distribution bars ≤ 5d or 450 mm (d = effective depth)

🏷7. Bending Moment Check
Calculate design bending moments.

🚧Ensure: Mu ≤ φMn (or equivalent safety format per code)

🏷8. Shear Check

⏺Slab should resist one-way shear without shear reinforcement in most cases.

🚧Ensure:
Vu ≤ Vc
If Vu > Vc → increase slab thickness.

🏷9. Deflection Control

⏺Satisfy span-to-depth ratios.
Long-term deflection (creep + shrinkage) must be within limits.

🏷10. Crack Control

⏺Limit bar spacing and stress in steel.
⏺Proper curing is essential to minimize cracking.

🏷11. Cover to Reinforcement
Minimum clear cover (typical values):

⏺Interior slab: 20–25 mm
⏺Exposed or aggressive environment: 30–40 mm

🏷12. Construction & Detailing Requirements

⏺Proper formwork alignment
Correct bar placement and spacing Adequate compaction (vibration)
⏺Minimum curing period (7–14 days)

🏷13. Serviceability & Durability

⏺Control cracking and deflection Ensure fire resistance and long-term durability
⏺Consider waterproofing for roofs and wet areas

@etconp
❤10🙏9
ታምራት ፕሌት እና ጄ ቦልት አቅራቢ

✅የምንሰጣቸው አገልግሎቶች

🔅 ፕሌት any Size & thickness
🔅 ጄ ቦልት (ጥርስ ማዉጣትና ማጠፍ)

🔅 የተለያዩ  [modefic] ስራዎችን እንሰራለን።

♦️ ማንኛዉንም ብረታ ብረት እንገዛለን።

☎️ስልክ 0904040477 ወይም 0911016833 ደውለው ያግኙን
📱ቴሌግራም ላይ ፦https://t.me/heavenic1

አድራሻ፦  ቁ 1.መርካቶ
                ቁ.2 አየር ጤና  ኪዳነ ምህረት
                 ቁ.3 ቄራ

ጥራትና ታማኝነት መለያችን ነው።
ታምራት ፕሌት እና ጄ ቦልት አቅራቢ
❤4👍2
👉Design Requirements of Shear Walls according to EBCS (Ethiopian Building Code Standards)

🚧1. Purpose of Shear Wall

💫Shear walls are structural elements provided to:
⏺Resist lateral loads (earthquake & wind)
⏺Control story drift
Increase stiffness and strength of buildings
⏺Improve seismic performance, especially for mid- and high-rise buildings

🚧2. Location & Layout Requirements

💫According to EBCS-8: Shear walls shall be:
⏺Continuous from foundation to roof
⏺Uniformly distributed in plan to avoid torsion
⏺Preferably placed:
At building cores (stairs, elevators)
⏺Symmetrically in both X and Y directions
⏺Avoid: Sudden termination of walls and Large offsets or irregular wall alignment

🚧3. Thickness Requirements
As per EBCS-2:

💫Minimum wall thickness:
⏺150 mm for low-rise buildings
⏺200 mm or more for multi-storey buildings

⚡️Thickness must satisfy:Slenderness limits,Fire resistance,Durability requirements

🚧4. Material Requirements
Concrete

⏺Minimum concrete grade:
C25 (fck ≥ 25 MPa) for seismic areas
⏺Good compaction and curing are mandatory

⚡️Reinforcement Steel
⏺Deformed bars with:
fy = 300–500 Mpa

🚧5. Reinforcement Requirements (Very Important)

🏷5.1 Vertical Reinforcement
Minimum vertical steel ratio:
ρv ≥ 0.0025 (0.25%)
Bars: Uniformly distributed
⏺Minimum bar diameter: Ø10 mm
⏺Spacing: ≤ 300 mm

🏷5.2 Horizontal Reinforcement
⏺Minimum horizontal steel ratio: ρh ≥ 0.0025
⏺Spacing: ≤ 300 mm

📍Purpose:
⏺Control cracking
⏺Improve ductility

🚧6. Boundary Elements (Seismic Requirement)

⏺According to EBCS-8: Boundary elements are mandatory when:

🔰Wall is heavily stressed High axial force exists
🎲Requirements:

⏺Confined reinforcement (ties/stirrups)
⏺Tie spacing: ≤ 100 mm near ends
⏺Boundary zone width: ≥ max( wall thickness, 300 mm )

🚧7. Openings in Shear Walls

💫Openings (doors/windows) must:
⏺Be limited in size
⏺Be properly reinforced around edges
⏺Lintels and coupling beams:
Must be designed for shear + bending
⏺Require diagonal reinforcement in seismic zones

🚧8. Seismic Design Provisions (EBCS-8)

💫Shear walls must be designed for:
⏺Design base shear
⏺Overstrength factor
⏺Ductile detailing is compulsory:
⏺Proper anchorage
⏺Lap splices away from critical zones
⏺Drift limits must be checked:
Inter-story drift ≤ allowable limit

🚧9. Foundation Connection

💫Shear walls must be:

⏺Rigidly connected to foundation
⏺Proper dowel bars and development length provided
⚡️Foundation must resist:
⏺Overturning
⏺Sliding

🚧10. Construction & Quality Control

💫Accurate bar placement
Proper cover:

⏺≥ 25–40 mm depending on exposure
⏺Continuous supervision is required

📜Conclusion

💫According to EBCS, a shear wall must be:

⏺Properly located
⏺Adequately thick
⏺Correctly reinforced
⏺Detailed for ductility and seismic resistance
⏺Fully integrated with foundation and slabs

@etconp