👉በነገራችን ላይ ለዛሬ ብቻ የሚቆይ Full ኳንቲቲ ሰርቨይንግ Online Course ለምትወስዱ የ ETABS ኮርስ በነፃ ይመረቅላቹዋል❤️
🚀 ዛሬውኑ ይመዝገቡ እና የ Quantity Surveying ክህሎትዎን ወደ ሌላ ደረጃ ያሳድጉ!
⭐️ኮርሱ ለመጀመር👇
https://ye-buna.com/etconp?ref=product_detail&product=6a5e233a9c5e0_etconp
🚀 ዛሬውኑ ይመዝገቡ እና የ Quantity Surveying ክህሎትዎን ወደ ሌላ ደረጃ ያሳድጉ!
⭐️ኮርሱ ለመጀመር👇
https://ye-buna.com/etconp?ref=product_detail&product=6a5e233a9c5e0_etconp
👌2
👉ኮንስትራክሽን ሳይት ላይ የሚጠቅሙ Template Format ዶክመንቶች ከታች ባለው ሊንክ ያውርዱ👇
🌟ከ ፎርማቶቹ Site Diary,Site Book እና ሌሎች ተካቶባቹዋል
https://ye-buna.com/etconp?ref=product_detail&product=6a740ccd63237_etconp
🌟ከ ፎርማቶቹ Site Diary,Site Book እና ሌሎች ተካቶባቹዋል
https://ye-buna.com/etconp?ref=product_detail&product=6a740ccd63237_etconp
❤6👌1
👉ስለ ጠጠር (Aggregate) ይህን ያውቃሉ?
🌟በማንኛውም ግንባታ ውስጥ ከ 60% እስከ 75% የሚሆነውን የኮንክሪት አካል የሚሸፍነው (ጠጠር እና አሸዋ) መሆኑን ያውቃሉ? ጠጣሩ ለህንጻዎ ጥንካሬ እና ዘላቂነት ዋናው መሠረት ነው!
⬇️ዋና ዋና የጠጠር ዓይነቶች፡
1. ደቅቅ ጠጠር (Fine Aggregate)፡ መጠናቸው ከ 4.75 ሚ.ሜ በታች የሆኑ (እንደ አሸዋ ያሉ) ሲሆኑ፤ በትልልቅ ጠጠሮች መካከል ያለውን ክፍተት ይሞላሉ።
2. ግዙፍ ጠጠር (Coarse Aggregate)፡ መጠናቸው ከ 4.75 ሚ.ሜ በላይ የሆኑ ጠጠሮች ሲሆኑ፤ ለኮንክሪት ዋናውን የመሸከም አቅም ይሰጣሉ።
🗂ጥራት ያለው አግሪጌት መጠቀም ያለው ጥቅም፡-
.የኮንክሪት የመሸከም አቅምን ይጨምራል።
. ሲሚንቶ ሲደርቅ የሚፈጠርን መሰነጣጠቅ ይከላከላል።
. አላስፈላጊ የሲሚንቶ ብክነትን በመቀነስ ወጪን ይቆጥባል።
🚥ተመሳሳይ ሙያዊ የሳይት ኢንጂነሪንግ መረጃዎችን ለማግኘት የ YouTube ገጻችንን Subscribe ያድርጉ👇
https://youtube.com/@ethiopianconstruction7?si=ils307xXQQpIdCwG
@etconp
🌟በማንኛውም ግንባታ ውስጥ ከ 60% እስከ 75% የሚሆነውን የኮንክሪት አካል የሚሸፍነው (ጠጠር እና አሸዋ) መሆኑን ያውቃሉ? ጠጣሩ ለህንጻዎ ጥንካሬ እና ዘላቂነት ዋናው መሠረት ነው!
⬇️ዋና ዋና የጠጠር ዓይነቶች፡
1. ደቅቅ ጠጠር (Fine Aggregate)፡ መጠናቸው ከ 4.75 ሚ.ሜ በታች የሆኑ (እንደ አሸዋ ያሉ) ሲሆኑ፤ በትልልቅ ጠጠሮች መካከል ያለውን ክፍተት ይሞላሉ።
2. ግዙፍ ጠጠር (Coarse Aggregate)፡ መጠናቸው ከ 4.75 ሚ.ሜ በላይ የሆኑ ጠጠሮች ሲሆኑ፤ ለኮንክሪት ዋናውን የመሸከም አቅም ይሰጣሉ።
🗂ጥራት ያለው አግሪጌት መጠቀም ያለው ጥቅም፡-
.የኮንክሪት የመሸከም አቅምን ይጨምራል።
. ሲሚንቶ ሲደርቅ የሚፈጠርን መሰነጣጠቅ ይከላከላል።
. አላስፈላጊ የሲሚንቶ ብክነትን በመቀነስ ወጪን ይቆጥባል።
🚥ተመሳሳይ ሙያዊ የሳይት ኢንጂነሪንግ መረጃዎችን ለማግኘት የ YouTube ገጻችንን Subscribe ያድርጉ👇
https://youtube.com/@ethiopianconstruction7?si=ils307xXQQpIdCwG
@etconp
❤14🥰1
👉በሳይት ላይ የStone Masonry Material (የድንጋይ ጥራት) ቁጥጥር! 🧐🏗️
🌟በምስሉ ላይ እንደምናየው ለፋውንዴሽን ወይም ለሪቴይኒንግ ቮል (Retaining Wall/Masonry Work) የሚያገለግል የድንጋይ አቅርቦት በቲፐር መኪና ወደ ሳይት እየወረደ ይገኛል።
🗂የድንጋይ አቅርቦት በሚቀበሉበት ጊዜ ሊዘነጉ የማይገባቸው ዋና ዋና የጥራት ቁጥጥር ነጥቦች፦
1. Soundness & Hardness: ድንጋዩ ጠንካራ (Hard)፣ ከተጣበቀ አፈርና ቆሻሻ ነፃ የሆነ እና በመዶሻ ሲመታ የሚጣራ ድምፅ የሚያወጣ (Sound Rock) መሆኑን ማረጋገጥ።
2. Weathering & Fractures: ስንጥቅ ያለበት፣ የበሰበሰ ወይም አየሩ ሲቀያየር በቀላሉ የሚሸረረፍ ድንጋይ (Weathered Rock) አለመሆኑን መቆጣጠር።
3. Size & Shape: ለስራው ምቹ የሆነ መጠንና ቅርፅ (Angular Shape) ያለው ድንጋይ መሆኑን ማየት፤ ከመጠን በላይ ድቡልቡል የሆኑ ድንጋዮች በሞርታር ለመያያዝ አስቸጋሪ ናቸው።
በእርስዎ ሳይት ላይ የሜሶነሪ ድንጋይ አቅርቦት ሲረከቡ የጭነቱን መጠን (Volume) በኩብ (m^3) እንዴት ይረከባሉ? ሃሳብዎን በኮሜንት ያካፍሉን!👇
💡 ተመሳሳይ የሳይት ኢንጂነሪንግ መረጃዎችን ለማግኘት የፌስቡክ ገፃችን Follow ያድርጉ👇
https://www.facebook.com/profile.php?id=61592085774934
@etconp
🌟በምስሉ ላይ እንደምናየው ለፋውንዴሽን ወይም ለሪቴይኒንግ ቮል (Retaining Wall/Masonry Work) የሚያገለግል የድንጋይ አቅርቦት በቲፐር መኪና ወደ ሳይት እየወረደ ይገኛል።
🗂የድንጋይ አቅርቦት በሚቀበሉበት ጊዜ ሊዘነጉ የማይገባቸው ዋና ዋና የጥራት ቁጥጥር ነጥቦች፦
1. Soundness & Hardness: ድንጋዩ ጠንካራ (Hard)፣ ከተጣበቀ አፈርና ቆሻሻ ነፃ የሆነ እና በመዶሻ ሲመታ የሚጣራ ድምፅ የሚያወጣ (Sound Rock) መሆኑን ማረጋገጥ።
2. Weathering & Fractures: ስንጥቅ ያለበት፣ የበሰበሰ ወይም አየሩ ሲቀያየር በቀላሉ የሚሸረረፍ ድንጋይ (Weathered Rock) አለመሆኑን መቆጣጠር።
3. Size & Shape: ለስራው ምቹ የሆነ መጠንና ቅርፅ (Angular Shape) ያለው ድንጋይ መሆኑን ማየት፤ ከመጠን በላይ ድቡልቡል የሆኑ ድንጋዮች በሞርታር ለመያያዝ አስቸጋሪ ናቸው።
በእርስዎ ሳይት ላይ የሜሶነሪ ድንጋይ አቅርቦት ሲረከቡ የጭነቱን መጠን (Volume) በኩብ (m^3) እንዴት ይረከባሉ? ሃሳብዎን በኮሜንት ያካፍሉን!👇
💡 ተመሳሳይ የሳይት ኢንጂነሪንግ መረጃዎችን ለማግኘት የፌስቡክ ገፃችን Follow ያድርጉ👇
https://www.facebook.com/profile.php?id=61592085774934
@etconp
❤7👍4
👉አዲስ በተሰራ የሰላብ ኮንክሪት ላይ የሚታዩ ስንጥቆች (Plastic Shrinkage Cracks) መንስኤ እና መፍትሄዎች! 🧐🏗️
🌟በምስሉ ላይ እንደምናየው ኮንክሪቱ ገና ሳይደርቅና ጠንካራ ሳይሆን በፊት በላዩ ላይ የሸረሪት ድር የሚመስሉ ስንጥቆች (Craze/Shrinkage Cracks) ተፈጥረዋል።
🗂ዋና ዋና መንስኤዎች፦
1. High Evaporation Rate: በሞቃት አየር፣ ከፍተኛ ንፋስ ወይም አነስተኛ እርጥበት ምክንያት በኮንክሪት ውስጥ ያለው ውሃ ፈጥኖ ሲተነን።
2. Delayed Curing: ኮንክሪት ከተፈሰሰና ከተስተካከለ በኋላ ወዲያውኑ ውሀ አለመርጨት (Curing) ወይም አለመሸፈን።
3. Excessive Water-Cement Ratio: በስራ ወቅት ከመጠን በላይ ውሃ መጠቀም (High W/C Ratio)።
⬆️በእርስዎ ሳይት ላይ በሞቃት አየር ውስጥ ሰላብ ሲያፈሱ Plastic Shrinkage ለመከላከል ምን ዓይነት ዘዴ (Curing Compound, Wet Burlap, ወይስ Fogging) ይጠቀማሉ? ሃሳብዎን በኮሜንት ያካፍሉን!
👌በነገራችን ላይ ሌላኛው ቻናላችን ተቀላቅለዋል?
⚡️ሰሙኑ የወጡ ጨረታዎች ጨምሮ
🌟አዳዲስ የስራ ቅጥሮች እና የኮንስትራክሽን ጨረታዎች ሲወጡ በቀላሉና በ ትኩሱ ለመመልከት ከታች ባለው ሊንካችን ይቀላቀሉን።
📌እንዲሁም ለወዳጆቻቹ SHARE በማረግ አዳርሱ👇
https://t.me/ETCONpWORK
https://t.me/ETCONpWORK
https://t.me/ETCONpWORK
🌟በምስሉ ላይ እንደምናየው ኮንክሪቱ ገና ሳይደርቅና ጠንካራ ሳይሆን በፊት በላዩ ላይ የሸረሪት ድር የሚመስሉ ስንጥቆች (Craze/Shrinkage Cracks) ተፈጥረዋል።
🗂ዋና ዋና መንስኤዎች፦
1. High Evaporation Rate: በሞቃት አየር፣ ከፍተኛ ንፋስ ወይም አነስተኛ እርጥበት ምክንያት በኮንክሪት ውስጥ ያለው ውሃ ፈጥኖ ሲተነን።
2. Delayed Curing: ኮንክሪት ከተፈሰሰና ከተስተካከለ በኋላ ወዲያውኑ ውሀ አለመርጨት (Curing) ወይም አለመሸፈን።
3. Excessive Water-Cement Ratio: በስራ ወቅት ከመጠን በላይ ውሃ መጠቀም (High W/C Ratio)።
⬆️በእርስዎ ሳይት ላይ በሞቃት አየር ውስጥ ሰላብ ሲያፈሱ Plastic Shrinkage ለመከላከል ምን ዓይነት ዘዴ (Curing Compound, Wet Burlap, ወይስ Fogging) ይጠቀማሉ? ሃሳብዎን በኮሜንት ያካፍሉን!
👌በነገራችን ላይ ሌላኛው ቻናላችን ተቀላቅለዋል?
⚡️ሰሙኑ የወጡ ጨረታዎች ጨምሮ
🌟አዳዲስ የስራ ቅጥሮች እና የኮንስትራክሽን ጨረታዎች ሲወጡ በቀላሉና በ ትኩሱ ለመመልከት ከታች ባለው ሊንካችን ይቀላቀሉን።
📌እንዲሁም ለወዳጆቻቹ SHARE በማረግ አዳርሱ👇
https://t.me/ETCONpWORK
https://t.me/ETCONpWORK
https://t.me/ETCONpWORK
❤12👍3🙏3
👉የመስኖ ቦይ ዲዛይን ደረጃዎች (OGL, CBL, TBL እና ሌሎችን) በጥልቀት እንመለከታለን
☄በመስኖ ቦይ (Irrigation Canal) ዲዛይን ውስጥ የሚገኙ የከፍታ (Elevation) ወይም Levels መለኪያዎች የቦዩን አቀማመጥ (Vertical Alignment) ለመወሰን መሠረታዊ ሚና ይጫወታሉ።
🚥እነዚህ ደረጃዎች ውሃው በስበት ኃይል (Gravity) እንዲፈስ፣ የቦዩ መዋቅር ደህንነት እንዲጠበቅ፣ እንዲሁም የቁፋሮ (Cut) እና የሙሌት (Fill) ስራዎች ኢኮኖሚያዊ እንዲሆኑ ያግዛሉ።
1. OGL (Original Ground Level) – የመጀመሪያው የመሬት ወለል ደረጃ
OGL ማለት ማንኛውም የቁፋሮ፣ የሙሌት ወይም የግንባታ ሥራ ከመጀመሩ በፊት በተፈጥሮ የነበረው የመሬት ከፍታ (Natural Ground Elevation) ነው።
ይህ ከTopographic Survey የሚገኝ መረጃ ነው።
▢ ለሁሉም የቦይ ዲዛይን መነሻ መረጃ ነው።
▢ የCut እና Fill መጠንን ይወስናል።
▢ የEarthwork መጠንን ለማስላት ይጠቅማል።
▢ የቦዩን አቀማመጥ ለመወሰን ይረዳል።
▢ የAqueduct፣ Culvert፣ Siphon እና ሌሎች መዋቅሮች ዲዛይን መሠረት ነው።
2. CBL (Canal Bed Level) – የቦዩ ግርጌ ደረጃ
CBL ማለት ውሃው የሚፈስበት የቦዩ ታችኛው ክፍል (Bottom Surface) የተዘጋጀ የዲዛይን ከፍታ ነው።
አንዳንድ ጊዜ
Canal Invert Level
Canal Bottom Level
ተብሎም ይጠራል።
CBL የሚቆጣጠረው፦
የውሃ ፍሰት
የቦዩ ቁልቁለት (Slope)
የውሃ ፍጥነት
የደለል (Sediment) እንቅስቃሴ
የቦዩ የሃይድሮሊክ ብቃት
CBL በትክክል ካልተዘጋጀ ወይም ካልተገነባ የቦዩ መሸርሸር (Erosion) ወይም የደለል ክምችት (Sedimentation) ሊፈጠር ይችላል።
3. FSL (Full Supply Level) – የሙሉ አቅርቦት የውሃ ወለል ደረጃ
FSL ማለት ቦዩ በተዘጋጀው የዲዛይን ፍሰት (Design Discharge) ሲሰራ የውሃው ወለል የሚደርስበት ከፍታ ነው።
FSL = CBL + የውሃ ጥልቀት (Water Depth)
የመስኖ አገልግሎት የሚያገኘውን አካባቢ (Command Area) ይወስናል።
የመስኖ ውሃ መውጫዎች (Outlets) ከፍታ ይወስናል።
የሃይድሮሊክ ዲዛይን መሠረት ነው።
4. FSD (Full Supply Depth) – የሙሉ አቅርቦት የውሃ ጥልቀት
FSD ማለት በCBL እና FSL መካከል ያለው ቀጥ ርቀት ነው።
FSD = FSL − CBL
5. TBL (Top Bank Level) – የቦዩ ከፍተኛ የግድብ ደረጃ
TBL ማለት የቦዩ ዳርቻ (Bank) ከፍተኛ የተጠናቀቀ ከፍታ ነው።
ዓላማው
ውሃ ከቦዩ እንዳይፈስስ (Overtopping) ይከላከላል።
የቦዩን መዋቅራዊ ጥንካሬ ይጠብቃል።
የጥገና መንገድ ለመገንባት ያስችላል።
ቀመር
TBL = FSL + Freeboard
6. Freeboard – የደህንነት ከፍታ
Freeboard ማለት በFSL እና TBL መካከል ያለው የደህንነት ክፍተት ነው።
ዓላማው፦
የሞገድ ተፅዕኖን መቀነስ
የውሃ መጠን ለውጥን መቋቋም
የአፈር መቀመጥ (Settlement) ለማካካስ
ውሃ ከቦዩ እንዳይፈስስ መከላከል
7. WSL (Water Surface Level) – የውሃ ወለል ደረጃ
WSL ማለት በማንኛውም የሥራ ሁኔታ የውሃው እውነተኛ ወለል ከፍታ ነው።
በDesign Flow → WSL = FSL
በዝቅተኛ ፍሰት → WSL < FSL
8. Formation Level (FL) – የተዘጋጀ የመሠረት ደረጃ
Formation Level ማለት ከEarthwork በኋላ ለግንባታ የተዘጋጀው የመሬት ደረጃ ነው።
በUnlined Canal ብዙ ጊዜ FL = CBL
በLined Canal ደግሞ FL ከLining በታች ያለውን የመሠረት ደረጃ ያመለክታል።
9. Lining Level (LL) – የማልበሻ ደረጃ
Lining Level ማለት የኮንክሪት፣ የድንጋይ፣ የጡብ ወይም የHDPE መሸፈኛ የመጨረሻ ወለል ደረጃ ነው።
10. Excavation Level (EL) – የቁፋሮ ደረጃ
EL ማለት የዲዛይን ቦይ ለማግኘት መሬቱ የሚቆፈርበት እስከሚደርስበት ደረጃ ነው።
11. Embankment Level (EBL) – የግድብ ሙሌት ደረጃ
ቦዩ ከተፈጥሮ መሬት በላይ በሚገነባበት ጊዜ የሚሞላው አፈር የሚደርስበት የተጠናቀቀ ከፍታ ነው።
12. Bank Toe Level – የግድብ ግርጌ ደረጃ
የግድቡ ዳር ቁልቁለት ከተፈጥሮ መሬት ጋር የሚገናኝበት ነጥብ ነው።
ይህ ለ
የተዳፋት መረጋጋት
የአፈር ጥበቃ
የEarthwork ስሌት
በጣም አስፈላጊ ነው።
13. Bank Crest Level (BCL) – የግድብ አናት ደረጃ
BCL ማለት የግድቡ ከፍተኛ የተጠናቀቀ ከፍታ ነው።
በአብዛኛው
BCL = TBL
14. High Flood Level (HFL) – ከፍተኛ የጎርፍ ውሃ ደረጃ
HFL ማለት በወንዝ ወይም በጎርፍ መስመር ላይ ሊደርስ የሚችለው ከፍተኛው የውሃ ከፍታ ነው።
ይህ በAqueduct፣ Culvert፣ Siphon እና ሌሎች የመስቀል መዋቅሮች (Cross-Drainage Structures) ዲዛይን ላይ ወሳኝ ነው።
15. Lowest Bed Level (LBL) – ዝቅተኛው የቦይ ግርጌ ደረጃ
LBL ማለት በቦዩ መጨረሻ ክፍል የሚገኘው ዝቅተኛው የCBL ከፍታ ነው።
ይህ ለ
የግራቪቲ ፍሰት ማረጋገጫ
የማስወገጃ ሁኔታ
የመጨረሻ የውሃ መውጫ ዲዛይን
ጠቃሚ ነው።
የካናል ወይም ቦይ ዲዛይን ከፍታዎች ግንኙነት
TBL (የቦዩ ከፍተኛ የግድብ ደረጃ)
─────────────────────
Freeboard (የደህንነት ክፍተት)
~ FSL (የሙሉ የውሃ ወለል) ~
የውሃ ጥልቀት (Water Depth)
─────────────────────
CBL (የቦዩ ግርጌ ደረጃ)
─────────────────────
Formation Level / Lining Level
─────────────────────
OGL (የመጀመሪያው የመሬት ወለል)
የዲዛይን ምሳሌ
መለኪያ
ከፍታ (m)
OGL
1523.80
CBL
1522.50
የውሃ ጥልቀት
1.20
FSL
1523.70
Freeboard
0.60
TBL
1524.30
በመስኖ ኢንጂነሪንግ ውስጥ የእነዚህ ደረጃዎች አስፈላጊነት
ውሃ በስበት ኃይል (Gravity) በተረጋጋ ሁኔታ እንዲፈስ ያስችላሉ።
የውሃ ፍጥነትን በመቆጣጠር መሸርሸር (Erosion) እና የደለል ክምችት (Sedimentation) እንዳይፈጠር ይረዳሉ።
የቁፋሮ (Cut) እና የሙሌት (Fill) መጠንን በማመጣጠን የግንባታ ወጪን ይቀንሳሉ።
በቂ Freeboard በመስጠት ውሃ ከቦዩ እንዳይፈስስ ይከላከላሉ።
እንደ መቆጣጠሪያ በሮች (Head Regulators)፣ Cross Regulators፣ Escapes፣ Culverts፣ Aqueducts፣ Siphons እና የመስኖ ውሃ መውጫዎች (Outlets) ያሉ መዋቅሮችን ለመንደፍ መሠረት ይሆናሉ።
የመስኖ መሬት (Command Area) ከፍታ ጋር ተስማሚ የውሃ ስርጭት እንዲኖር ያግዛሉ።
በሥራ መለኪያ (Setting Out)፣ በግንባታ ቁጥጥር እና በጥገና ሂደቶች ውስጥ ትክክለኛ መመሪያ ይሰጣሉ።
Via Infra
@etconp
☄በመስኖ ቦይ (Irrigation Canal) ዲዛይን ውስጥ የሚገኙ የከፍታ (Elevation) ወይም Levels መለኪያዎች የቦዩን አቀማመጥ (Vertical Alignment) ለመወሰን መሠረታዊ ሚና ይጫወታሉ።
🚥እነዚህ ደረጃዎች ውሃው በስበት ኃይል (Gravity) እንዲፈስ፣ የቦዩ መዋቅር ደህንነት እንዲጠበቅ፣ እንዲሁም የቁፋሮ (Cut) እና የሙሌት (Fill) ስራዎች ኢኮኖሚያዊ እንዲሆኑ ያግዛሉ።
1. OGL (Original Ground Level) – የመጀመሪያው የመሬት ወለል ደረጃ
OGL ማለት ማንኛውም የቁፋሮ፣ የሙሌት ወይም የግንባታ ሥራ ከመጀመሩ በፊት በተፈጥሮ የነበረው የመሬት ከፍታ (Natural Ground Elevation) ነው።
ይህ ከTopographic Survey የሚገኝ መረጃ ነው።
▢ ለሁሉም የቦይ ዲዛይን መነሻ መረጃ ነው።
▢ የCut እና Fill መጠንን ይወስናል።
▢ የEarthwork መጠንን ለማስላት ይጠቅማል።
▢ የቦዩን አቀማመጥ ለመወሰን ይረዳል።
▢ የAqueduct፣ Culvert፣ Siphon እና ሌሎች መዋቅሮች ዲዛይን መሠረት ነው።
2. CBL (Canal Bed Level) – የቦዩ ግርጌ ደረጃ
CBL ማለት ውሃው የሚፈስበት የቦዩ ታችኛው ክፍል (Bottom Surface) የተዘጋጀ የዲዛይን ከፍታ ነው።
አንዳንድ ጊዜ
Canal Invert Level
Canal Bottom Level
ተብሎም ይጠራል።
CBL የሚቆጣጠረው፦
የውሃ ፍሰት
የቦዩ ቁልቁለት (Slope)
የውሃ ፍጥነት
የደለል (Sediment) እንቅስቃሴ
የቦዩ የሃይድሮሊክ ብቃት
CBL በትክክል ካልተዘጋጀ ወይም ካልተገነባ የቦዩ መሸርሸር (Erosion) ወይም የደለል ክምችት (Sedimentation) ሊፈጠር ይችላል።
3. FSL (Full Supply Level) – የሙሉ አቅርቦት የውሃ ወለል ደረጃ
FSL ማለት ቦዩ በተዘጋጀው የዲዛይን ፍሰት (Design Discharge) ሲሰራ የውሃው ወለል የሚደርስበት ከፍታ ነው።
FSL = CBL + የውሃ ጥልቀት (Water Depth)
የመስኖ አገልግሎት የሚያገኘውን አካባቢ (Command Area) ይወስናል።
የመስኖ ውሃ መውጫዎች (Outlets) ከፍታ ይወስናል።
የሃይድሮሊክ ዲዛይን መሠረት ነው።
4. FSD (Full Supply Depth) – የሙሉ አቅርቦት የውሃ ጥልቀት
FSD ማለት በCBL እና FSL መካከል ያለው ቀጥ ርቀት ነው።
FSD = FSL − CBL
5. TBL (Top Bank Level) – የቦዩ ከፍተኛ የግድብ ደረጃ
TBL ማለት የቦዩ ዳርቻ (Bank) ከፍተኛ የተጠናቀቀ ከፍታ ነው።
ዓላማው
ውሃ ከቦዩ እንዳይፈስስ (Overtopping) ይከላከላል።
የቦዩን መዋቅራዊ ጥንካሬ ይጠብቃል።
የጥገና መንገድ ለመገንባት ያስችላል።
ቀመር
TBL = FSL + Freeboard
6. Freeboard – የደህንነት ከፍታ
Freeboard ማለት በFSL እና TBL መካከል ያለው የደህንነት ክፍተት ነው።
ዓላማው፦
የሞገድ ተፅዕኖን መቀነስ
የውሃ መጠን ለውጥን መቋቋም
የአፈር መቀመጥ (Settlement) ለማካካስ
ውሃ ከቦዩ እንዳይፈስስ መከላከል
7. WSL (Water Surface Level) – የውሃ ወለል ደረጃ
WSL ማለት በማንኛውም የሥራ ሁኔታ የውሃው እውነተኛ ወለል ከፍታ ነው።
በDesign Flow → WSL = FSL
በዝቅተኛ ፍሰት → WSL < FSL
8. Formation Level (FL) – የተዘጋጀ የመሠረት ደረጃ
Formation Level ማለት ከEarthwork በኋላ ለግንባታ የተዘጋጀው የመሬት ደረጃ ነው።
በUnlined Canal ብዙ ጊዜ FL = CBL
በLined Canal ደግሞ FL ከLining በታች ያለውን የመሠረት ደረጃ ያመለክታል።
9. Lining Level (LL) – የማልበሻ ደረጃ
Lining Level ማለት የኮንክሪት፣ የድንጋይ፣ የጡብ ወይም የHDPE መሸፈኛ የመጨረሻ ወለል ደረጃ ነው።
10. Excavation Level (EL) – የቁፋሮ ደረጃ
EL ማለት የዲዛይን ቦይ ለማግኘት መሬቱ የሚቆፈርበት እስከሚደርስበት ደረጃ ነው።
11. Embankment Level (EBL) – የግድብ ሙሌት ደረጃ
ቦዩ ከተፈጥሮ መሬት በላይ በሚገነባበት ጊዜ የሚሞላው አፈር የሚደርስበት የተጠናቀቀ ከፍታ ነው።
12. Bank Toe Level – የግድብ ግርጌ ደረጃ
የግድቡ ዳር ቁልቁለት ከተፈጥሮ መሬት ጋር የሚገናኝበት ነጥብ ነው።
ይህ ለ
የተዳፋት መረጋጋት
የአፈር ጥበቃ
የEarthwork ስሌት
በጣም አስፈላጊ ነው።
13. Bank Crest Level (BCL) – የግድብ አናት ደረጃ
BCL ማለት የግድቡ ከፍተኛ የተጠናቀቀ ከፍታ ነው።
በአብዛኛው
BCL = TBL
14. High Flood Level (HFL) – ከፍተኛ የጎርፍ ውሃ ደረጃ
HFL ማለት በወንዝ ወይም በጎርፍ መስመር ላይ ሊደርስ የሚችለው ከፍተኛው የውሃ ከፍታ ነው።
ይህ በAqueduct፣ Culvert፣ Siphon እና ሌሎች የመስቀል መዋቅሮች (Cross-Drainage Structures) ዲዛይን ላይ ወሳኝ ነው።
15. Lowest Bed Level (LBL) – ዝቅተኛው የቦይ ግርጌ ደረጃ
LBL ማለት በቦዩ መጨረሻ ክፍል የሚገኘው ዝቅተኛው የCBL ከፍታ ነው።
ይህ ለ
የግራቪቲ ፍሰት ማረጋገጫ
የማስወገጃ ሁኔታ
የመጨረሻ የውሃ መውጫ ዲዛይን
ጠቃሚ ነው።
የካናል ወይም ቦይ ዲዛይን ከፍታዎች ግንኙነት
TBL (የቦዩ ከፍተኛ የግድብ ደረጃ)
─────────────────────
Freeboard (የደህንነት ክፍተት)
~ FSL (የሙሉ የውሃ ወለል) ~
─────────────────────
CBL (የቦዩ ግርጌ ደረጃ)
─────────────────────
Formation Level / Lining Level
─────────────────────
OGL (የመጀመሪያው የመሬት ወለል)
የዲዛይን ምሳሌ
መለኪያ
ከፍታ (m)
OGL
1523.80
CBL
1522.50
የውሃ ጥልቀት
1.20
FSL
1523.70
Freeboard
0.60
TBL
1524.30
በመስኖ ኢንጂነሪንግ ውስጥ የእነዚህ ደረጃዎች አስፈላጊነት
ውሃ በስበት ኃይል (Gravity) በተረጋጋ ሁኔታ እንዲፈስ ያስችላሉ።
የውሃ ፍጥነትን በመቆጣጠር መሸርሸር (Erosion) እና የደለል ክምችት (Sedimentation) እንዳይፈጠር ይረዳሉ።
የቁፋሮ (Cut) እና የሙሌት (Fill) መጠንን በማመጣጠን የግንባታ ወጪን ይቀንሳሉ።
በቂ Freeboard በመስጠት ውሃ ከቦዩ እንዳይፈስስ ይከላከላሉ።
እንደ መቆጣጠሪያ በሮች (Head Regulators)፣ Cross Regulators፣ Escapes፣ Culverts፣ Aqueducts፣ Siphons እና የመስኖ ውሃ መውጫዎች (Outlets) ያሉ መዋቅሮችን ለመንደፍ መሠረት ይሆናሉ።
የመስኖ መሬት (Command Area) ከፍታ ጋር ተስማሚ የውሃ ስርጭት እንዲኖር ያግዛሉ።
በሥራ መለኪያ (Setting Out)፣ በግንባታ ቁጥጥር እና በጥገና ሂደቶች ውስጥ ትክክለኛ መመሪያ ይሰጣሉ።
Via Infra
@etconp
❤20🙏3
👉የ C-25 Concrete Cost Breakdown & Detailed Calculation ከነ Excel እና PDF Note ከፈለጉ ከታች ባለው ሊንክ ያውርዱት👇
https://ye-buna.com/etconp?ref=product_detail&product=6a86960fc21e9_etconp
https://ye-buna.com/etconp?ref=product_detail&product=6a86960fc21e9_etconp
❤3👏1
👉በግንባታ ስራ ላይ የብረት (Rebar) ዋና ጥቅም ምንድን ነው?🏗️
☄ብዙ ጊዜ "ኮንክሪት ጠንካራ ከሆነ ብረት ለምን ያስፈልገዋል?" የሚል ጥያቄ ይነሳል። መልሱ የኮንክሪት እና የብረት ተፈጥሮአዊ ባህሪ ይለያያል!
🏛ብረት በመዋቅር ውስጥ የሚሰጣቸው 3 ወሳኝ ጥቅሞች፦
1. የመወጠር ኃይልን መሸከም (High Tensile Strength)፦
ኮንክሪት የመጫን ኃይልን (Compressive Force) የመቋቋም ከፍተኛ አቅም ቢኖረውም፣ የመወጠር ኃይልን (Tensile Force) ግን መቋቋም አይችልም። ብረት በኮንክሪት ውስጥ ሲገባ ይህንን የመወጠር ኃይል በመሸከም ቢም እና ሰላብ እንዳይሰነጠቁ ያደርጋል።
2. የመተጣጠፍ እና የመለጠጥ ባህሪ (Ductility)፦
የመሬት መንቀጥቀጥ ወይም ከፍተኛ የጎንዮሽ ኃይል በሚመጣበት ጊዜ መዋቅሩ ሳይፈርስ ወይም ሳይቆረጥ በቂ የመታጠፍ ዕድል (Deformation) እንዲኖረው በማድረግ ድንገተኛ የመፍረስ አደጋን ይከላከላል።
3. የስንጥቅ ቁጥጥር እና የሙቀት መጣጣን (Crack Control & Thermal Expansion)፦
በኮንክሪት ድርቀት (Shrinkage) የሚፈጠሩ ስንጥቆችን ይይዛል። በተጨማሪም የብረት እና የኮንክሪት የሙቀት መስፋፋት መጠን (12 * 10^-6 /°C}) እጅግ ተቀራራቢ በመሆኑ፣ በሙቀትና በብርድ ወቅት ሁለቱም አካላት አብረው በመስፋፋትና በመኮማተር ሳይላቀቁ በጥሩ ትስስር (Bond) ይሰጣሉ።
🚥ተመሳሳይ ሙያዊ የሳይት ኢንጂነሪንግ መረጃዎችን ለማግኘት የ YouTube ገጻችንን Subscribe ያድርጉ👇
https://youtube.com/@ethiopianconstruction7?si=ils307xXQQpIdCwG
@etconp
☄ብዙ ጊዜ "ኮንክሪት ጠንካራ ከሆነ ብረት ለምን ያስፈልገዋል?" የሚል ጥያቄ ይነሳል። መልሱ የኮንክሪት እና የብረት ተፈጥሮአዊ ባህሪ ይለያያል!
🏛ብረት በመዋቅር ውስጥ የሚሰጣቸው 3 ወሳኝ ጥቅሞች፦
1. የመወጠር ኃይልን መሸከም (High Tensile Strength)፦
ኮንክሪት የመጫን ኃይልን (Compressive Force) የመቋቋም ከፍተኛ አቅም ቢኖረውም፣ የመወጠር ኃይልን (Tensile Force) ግን መቋቋም አይችልም። ብረት በኮንክሪት ውስጥ ሲገባ ይህንን የመወጠር ኃይል በመሸከም ቢም እና ሰላብ እንዳይሰነጠቁ ያደርጋል።
2. የመተጣጠፍ እና የመለጠጥ ባህሪ (Ductility)፦
የመሬት መንቀጥቀጥ ወይም ከፍተኛ የጎንዮሽ ኃይል በሚመጣበት ጊዜ መዋቅሩ ሳይፈርስ ወይም ሳይቆረጥ በቂ የመታጠፍ ዕድል (Deformation) እንዲኖረው በማድረግ ድንገተኛ የመፍረስ አደጋን ይከላከላል።
3. የስንጥቅ ቁጥጥር እና የሙቀት መጣጣን (Crack Control & Thermal Expansion)፦
በኮንክሪት ድርቀት (Shrinkage) የሚፈጠሩ ስንጥቆችን ይይዛል። በተጨማሪም የብረት እና የኮንክሪት የሙቀት መስፋፋት መጠን (12 * 10^-6 /°C}) እጅግ ተቀራራቢ በመሆኑ፣ በሙቀትና በብርድ ወቅት ሁለቱም አካላት አብረው በመስፋፋትና በመኮማተር ሳይላቀቁ በጥሩ ትስስር (Bond) ይሰጣሉ።
🚥ተመሳሳይ ሙያዊ የሳይት ኢንጂነሪንግ መረጃዎችን ለማግኘት የ YouTube ገጻችንን Subscribe ያድርጉ👇
https://youtube.com/@ethiopianconstruction7?si=ils307xXQQpIdCwG
@etconp
❤8👍1
👉Possible Reasons for Removing Column Formwork at 8 Hours
1. Rapid-Hardening (High Early Strength) Concrete Was Used
If the contractor used rapid-hardening cement (RHC) or an accelerator admixture, the concrete can gain enough strength in 6–8 hours to allow formwork removal.
Example:
Quick setting concrete
Concrete with calcium nitrate/calcium chloride accelerators
Special high-early-strength mix
2. Very High Temperature Curing Conditions
In hot climates, concrete gains strength faster.
If the temperature is 30–35°C+, the surface concrete may harden quicker, sometimes allowing earlier removal.
3. Contractor Working Under Time Pressure or Poor Planning
Sometimes the contractor removes formwork early to:
*reuse formwork
*push schedule
*continue work above
***This is not a valid technical reason and is risky.
4. Very Light Formwork (Only Side Panels)
For columns, removing only the side panels earlier is possible because the column carries no load from above at this stage.
But 8 hours is still too early unless concrete strength is verified.
❌ Why It Is Usually NOT Allowed
Removing formwork at 8 hours may cause:
*surface damage / honeycombing
*corners chipping
*loss of shape
*structural weakness if strength is too low
Concrete normally needs:
5–7 MPa minimum strength before column formwork removal
Usually achieved at 24 hours, not 8.
✅ Correct Professional Answer
Formwork removal at 8 hours is only acceptable if the concrete is high-early-strength or contains an accelerator and if strength has been verified. Otherwise, it is not recommended and can damage the column.
@etconp
1. Rapid-Hardening (High Early Strength) Concrete Was Used
If the contractor used rapid-hardening cement (RHC) or an accelerator admixture, the concrete can gain enough strength in 6–8 hours to allow formwork removal.
Example:
Quick setting concrete
Concrete with calcium nitrate/calcium chloride accelerators
Special high-early-strength mix
2. Very High Temperature Curing Conditions
In hot climates, concrete gains strength faster.
If the temperature is 30–35°C+, the surface concrete may harden quicker, sometimes allowing earlier removal.
3. Contractor Working Under Time Pressure or Poor Planning
Sometimes the contractor removes formwork early to:
*reuse formwork
*push schedule
*continue work above
***This is not a valid technical reason and is risky.
4. Very Light Formwork (Only Side Panels)
For columns, removing only the side panels earlier is possible because the column carries no load from above at this stage.
But 8 hours is still too early unless concrete strength is verified.
❌ Why It Is Usually NOT Allowed
Removing formwork at 8 hours may cause:
*surface damage / honeycombing
*corners chipping
*loss of shape
*structural weakness if strength is too low
Concrete normally needs:
5–7 MPa minimum strength before column formwork removal
Usually achieved at 24 hours, not 8.
✅ Correct Professional Answer
Formwork removal at 8 hours is only acceptable if the concrete is high-early-strength or contains an accelerator and if strength has been verified. Otherwise, it is not recommended and can damage the column.
@etconp
❤10🙏4👍2
👉በአዲስ አበባ ከ90 ሺሕ በላይ ይዞታዎች የአስተዳደር ችግር መፈታቱ ተነገረ እንዲሁም ከ5.7 ሚሊዮን ብር በላይ ገቢ መሰብሰቡ ተገልጿል
በ2018 በጀት ዓመት በአዲስ አበባ ከተማ ከ90 ሺሕ በላይ ይዞታዎች የመልካም አስተዳደር ችግር ተፈቶ ወደ ልማት እንዲገቡ መደረጉን፣ የአስተዳደሩ ፕላንና ልማት ቢሮ ገለጸ፡፡
የአዲስ አበባ ከተማ አስተዳደር ፕላንና ልማት ቢሮ በ2018 በጀት ዓመት አፈጻጸሙ የልማት ተነሺዎችን በተመለከተ 5,160፣ የመዋቅራዊ ፕላን ጥናት ማሻሻያ 2,171፣ ከአካባቢ ልማት ጥናትና ከኮሪደር ልማት ጋር ለተገናኙ 256፣ ከውስጥ ለውስጥ መንገድ ጋር ለተነሱ 9,090፣ የጨረታ ቦታዎች 896፣ በምደባ የተላለፉ 96 እና 29 የአክሲዮን ማኅበር ቦታዎችን ጨምሮ በአጠቃላይ 93,641 ይዞታዎች ናቸው ተብለዋል።
Via የአዲስ አበባ ከተማ አስተዳደር ፕላንና ልማት ቢሮ
@etconp
በ2018 በጀት ዓመት በአዲስ አበባ ከተማ ከ90 ሺሕ በላይ ይዞታዎች የመልካም አስተዳደር ችግር ተፈቶ ወደ ልማት እንዲገቡ መደረጉን፣ የአስተዳደሩ ፕላንና ልማት ቢሮ ገለጸ፡፡
የአዲስ አበባ ከተማ አስተዳደር ፕላንና ልማት ቢሮ በ2018 በጀት ዓመት አፈጻጸሙ የልማት ተነሺዎችን በተመለከተ 5,160፣ የመዋቅራዊ ፕላን ጥናት ማሻሻያ 2,171፣ ከአካባቢ ልማት ጥናትና ከኮሪደር ልማት ጋር ለተገናኙ 256፣ ከውስጥ ለውስጥ መንገድ ጋር ለተነሱ 9,090፣ የጨረታ ቦታዎች 896፣ በምደባ የተላለፉ 96 እና 29 የአክሲዮን ማኅበር ቦታዎችን ጨምሮ በአጠቃላይ 93,641 ይዞታዎች ናቸው ተብለዋል።
Via የአዲስ አበባ ከተማ አስተዳደር ፕላንና ልማት ቢሮ
@etconp
👍5❤3
👉መሰረታዊ የ ፋውንዴሽን ኢንጅነሪንግ የምትስረዳ ምርጥ መፅሐፍ ከ ጉ ከታች ባለው ሊንክ ያውርዱ👇
🌟Foundation Engineering Fundamentals – Complete Introductory Ebook
https://ye-buna.com/etconp?ref=product_detail&product=6a8743a519501_etconp
🌟Foundation Engineering Fundamentals – Complete Introductory Ebook
https://ye-buna.com/etconp?ref=product_detail&product=6a8743a519501_etconp
Ye-Buna
Foundation Engineering — Complete Introduction & Practical Design Guide
Foundation Engineering — Complete Introduction & Practical… 199 ETB · 4 sold. Instant download from Ethio Construction Engineering on Ye-Buna. Pay with…
🥰3❤2
👉HOLLOW CONCRETE BLOCK (HCB) – CLASS B LABORATORY TESTS
🌟Class B Hollow Concrete Blocks are used for non-load bearing walls or medium-strength construction. To certify quality, the following laboratory tests are performed.
✅ 1. Compressive Strength Test
Standard: ASTM C140
Purpose: To measure block strength.
Typical Requirement for Class B HCB:
Minimum compressive strength: 3.5 MPa to 5.0 MPa (varies with project spec)
Test 3 blocks (average value)
✅ 2. Dimension & Shape Tolerance
Standard: ASTM C140 / ES Standard
Purpose: Check if the block meets size and shape requirements.
Requirements (typical):
Length, width, height within ±3 mm tolerance
Faces should be flat and perpendicular
No large cracks or visible defects
✅ 3. Density Test (Dry Density)
Purpose: Confirm block classification (lightweight, medium, or normal).
Typical values:
1400 – 1700 kg/m³ for Class B HCB
✅ 4. Water Absorption
Standard: ASTM C140
Requirement:
Water absorption ≤ 12–15%
High absorption indicates weak block quality.
✅ 5. Block Weight Measurement
Purpose: Ensure consistency and structural performance.
Values depend on block size (e.g., 150 mm, 200 mm thickness).
✅Optional Tests (if required)
Ultrasound pulse velocity test – for uniformity
Efflorescence test – check salt content
Moisture content
📌 Summary Table for Easy Use
Test Purpose Typical Requirement (Class B)
Compressive Strength Strength ≥ 3.5 – 5.0 MPa
Dimensions Size accuracy ± 3 mm tolerance
Density Quality classification 1400–1700 kg/m³
Water Absorption Durability ≤ 12–15%
Weight Consistency As per design block type
@etconp
🌟Class B Hollow Concrete Blocks are used for non-load bearing walls or medium-strength construction. To certify quality, the following laboratory tests are performed.
✅ 1. Compressive Strength Test
Standard: ASTM C140
Purpose: To measure block strength.
Typical Requirement for Class B HCB:
Minimum compressive strength: 3.5 MPa to 5.0 MPa (varies with project spec)
Test 3 blocks (average value)
✅ 2. Dimension & Shape Tolerance
Standard: ASTM C140 / ES Standard
Purpose: Check if the block meets size and shape requirements.
Requirements (typical):
Length, width, height within ±3 mm tolerance
Faces should be flat and perpendicular
No large cracks or visible defects
✅ 3. Density Test (Dry Density)
Purpose: Confirm block classification (lightweight, medium, or normal).
Typical values:
1400 – 1700 kg/m³ for Class B HCB
✅ 4. Water Absorption
Standard: ASTM C140
Requirement:
Water absorption ≤ 12–15%
High absorption indicates weak block quality.
✅ 5. Block Weight Measurement
Purpose: Ensure consistency and structural performance.
Values depend on block size (e.g., 150 mm, 200 mm thickness).
✅Optional Tests (if required)
Ultrasound pulse velocity test – for uniformity
Efflorescence test – check salt content
Moisture content
📌 Summary Table for Easy Use
Test Purpose Typical Requirement (Class B)
Compressive Strength Strength ≥ 3.5 – 5.0 MPa
Dimensions Size accuracy ± 3 mm tolerance
Density Quality classification 1400–1700 kg/m³
Water Absorption Durability ≤ 12–15%
Weight Consistency As per design block type
@etconp
❤12
👉በሳይት ላይ የBathroom Plumbing System Inspection🚽
በምስሉ ላይ የመታጠቢያ ቤት የፍሳሽ መስመሮች አገጣጠም በቪዥዋል ደረጃ ፅዱ ይመስላል፤ ነገር ግን በፕላምቢንግ ስታንዳርድ (Plumbing Code) መሰረት ከባድ የዲዛይን ስህተቶች አሉበት!
በዚህ ዲዛይን ላይ የሚታዩ 3 ዋና ዋና የፕላምቢንግ ስህተቶች፦
1. Mixing Blackwater & Greywater: የሽንት ቤት ፍሳሽ (Blackwater) እና የመታጠቢያ/የሲንክ ፍሳሽ (Greywater) ያለ ምንም ልዩነት በቀጥታ በአንድ መስመር ተቀላቅለዋል። ይህ አሰራር የሽንት ቤት ቆሻሻ ወደ ሻወር ማፍሰሻው (Backflow) እንዲመለስ ያደርጋል!
2. Absence of P-Trap (Siphon): በሻወር (Floor Drain) እና በሲንክ ስር P-Trap (P-ትራፕ) አልተገጠመም። P-trap ከሌለ ከፍሳሽ ቱቦው የሚወጣው መጥፎ ሽታና ጋዝ (Sewer Gas) በቀጥታ ወደ መታጠቢያ ቤቱ ይገባል።
3. Direct 90degree Floor Drain Connection: የሻወር ፍሳሹ ከሽንት ቤት መስመር በኋላ በቅርብ ርቀት መቀላቀሉ የሽንት ቤት ፍለሽ በሚደረግበት ጊዜ የፍሳሽ ውሃ ወደ ሻወር ወለል እንዲፍለቀለቅ ያደርጋል።
በእርስዎ ሳይት ወይም ቤት ላይ የሽንት ቤት እና የሻወር ፍሳሽ መስመሮችን ለይታችሁ (Dual Pipe System) ነው ወይስ አቀላቅላችሁ ነው የምትሰሩት? ሃሳብዎን በኮሜንት ያካፍሉን!👇
@etconp
በምስሉ ላይ የመታጠቢያ ቤት የፍሳሽ መስመሮች አገጣጠም በቪዥዋል ደረጃ ፅዱ ይመስላል፤ ነገር ግን በፕላምቢንግ ስታንዳርድ (Plumbing Code) መሰረት ከባድ የዲዛይን ስህተቶች አሉበት!
በዚህ ዲዛይን ላይ የሚታዩ 3 ዋና ዋና የፕላምቢንግ ስህተቶች፦
1. Mixing Blackwater & Greywater: የሽንት ቤት ፍሳሽ (Blackwater) እና የመታጠቢያ/የሲንክ ፍሳሽ (Greywater) ያለ ምንም ልዩነት በቀጥታ በአንድ መስመር ተቀላቅለዋል። ይህ አሰራር የሽንት ቤት ቆሻሻ ወደ ሻወር ማፍሰሻው (Backflow) እንዲመለስ ያደርጋል!
2. Absence of P-Trap (Siphon): በሻወር (Floor Drain) እና በሲንክ ስር P-Trap (P-ትራፕ) አልተገጠመም። P-trap ከሌለ ከፍሳሽ ቱቦው የሚወጣው መጥፎ ሽታና ጋዝ (Sewer Gas) በቀጥታ ወደ መታጠቢያ ቤቱ ይገባል።
3. Direct 90degree Floor Drain Connection: የሻወር ፍሳሹ ከሽንት ቤት መስመር በኋላ በቅርብ ርቀት መቀላቀሉ የሽንት ቤት ፍለሽ በሚደረግበት ጊዜ የፍሳሽ ውሃ ወደ ሻወር ወለል እንዲፍለቀለቅ ያደርጋል።
በእርስዎ ሳይት ወይም ቤት ላይ የሽንት ቤት እና የሻወር ፍሳሽ መስመሮችን ለይታችሁ (Dual Pipe System) ነው ወይስ አቀላቅላችሁ ነው የምትሰሩት? ሃሳብዎን በኮሜንት ያካፍሉን!👇
@etconp
❤15👍5🙏1
👉መሰረታዊ የ ፋውንዴሽን ኢንጅነሪንግ የምትስረዳ ምርጥ መፅሐፍ ከታች ባለው ሊንክ ያውርዱ👇
🌟Foundation Engineering Fundamentals – Complete Introductory Ebook
https://ye-buna.com/etconp?ref=product_detail&product=6a8743a519501_etconp
🌟Foundation Engineering Fundamentals – Complete Introductory Ebook
https://ye-buna.com/etconp?ref=product_detail&product=6a8743a519501_etconp
Ye-Buna
Foundation Engineering — Complete Introduction & Practical Design Guide
Foundation Engineering — Complete Introduction & Practical… 199 ETB · 4 sold. Instant download from Ethio Construction Engineering on Ye-Buna. Pay with…
❤3
👉የግንባታ ፕሮጀክቶች ስኬት ለዘላቂ ተወዳዳሪነት 🏗️
የግንባታ ፕሮጀክቶች በታለመላቸው ጊዜ፣ በጀት እና ጥራት እንዲጠናቀቁ እና ለሀገር እድገት ያላቸው አስተዋጽኦ አስተማማኝ እንዲሆን የሚከተሉትን ቁልፍ ጉዳዮች መተግበር ያስፈልጋል፡ አስተዳደር እና አመራር፡ ግልጽ እቅድ፣ ቅንጅታዊ አሰራር፣ ውጤታማ ክትትል እና ፈጣን ውሳኔ ሰጪነት
የጥራት ቁጥጥር፡ የግብዓት፣ የሰው ሃይል እና የአፈጻጸም መመሪያዎችን በትክክል መከተል።
ብቃት ያለው የሰው ሃይል፡ ባለሙያዎችን መመደብ፣ ክህሎትን በስልጠና ማሳደግ እና ደህንነትን መጠበቅ።
ግዥና አቅርቦት፡ ማቴሪያሎችን፣ ማሽኖችን እና ፋይናንስን በህጋዊና ጥራት ባለው መልኩ ማስተዳደር።
ዘመናዊ ቴክኖሎጂ፡ የቢውልዲንግ ኢንፎርሜሽን ሞዴሊንግ (BIM) እና ዲጂታል የፕሮጀክት ማናጅመንት መጠቀም።
ዲዛይንና ደህንነት፡ ቴክኒካዊ ምሉዕነት ያለው ዲዛይን እና የሰራተኞች ጤንነትና ደህንነት አጠባበቅ ስርዓት።
ቅንጅትና ተግባቦት፡ የስራ ስህተቶችን ለመቀነስ እና ውጤታማነትን ለማሳደግ እንደ ኦርኬስትራ ተናቦ መስራት።
ማጠቃለያ፡
እነዚህን እሴቶች በቁርጠኝነት እና በሙያ ስነምግባር ስንተገብር የኮንስትራክሽን ዘርፉ ብቃት ያለውና ተወዳዳሪ በመሆን ለሀገራዊ የምርት ዕድገት ያለው ሚና የጎላ ይሆናል! 🇪🇹
@etconp
የግንባታ ፕሮጀክቶች በታለመላቸው ጊዜ፣ በጀት እና ጥራት እንዲጠናቀቁ እና ለሀገር እድገት ያላቸው አስተዋጽኦ አስተማማኝ እንዲሆን የሚከተሉትን ቁልፍ ጉዳዮች መተግበር ያስፈልጋል፡ አስተዳደር እና አመራር፡ ግልጽ እቅድ፣ ቅንጅታዊ አሰራር፣ ውጤታማ ክትትል እና ፈጣን ውሳኔ ሰጪነት
የጥራት ቁጥጥር፡ የግብዓት፣ የሰው ሃይል እና የአፈጻጸም መመሪያዎችን በትክክል መከተል።
ብቃት ያለው የሰው ሃይል፡ ባለሙያዎችን መመደብ፣ ክህሎትን በስልጠና ማሳደግ እና ደህንነትን መጠበቅ።
ግዥና አቅርቦት፡ ማቴሪያሎችን፣ ማሽኖችን እና ፋይናንስን በህጋዊና ጥራት ባለው መልኩ ማስተዳደር።
ዘመናዊ ቴክኖሎጂ፡ የቢውልዲንግ ኢንፎርሜሽን ሞዴሊንግ (BIM) እና ዲጂታል የፕሮጀክት ማናጅመንት መጠቀም።
ዲዛይንና ደህንነት፡ ቴክኒካዊ ምሉዕነት ያለው ዲዛይን እና የሰራተኞች ጤንነትና ደህንነት አጠባበቅ ስርዓት።
ቅንጅትና ተግባቦት፡ የስራ ስህተቶችን ለመቀነስ እና ውጤታማነትን ለማሳደግ እንደ ኦርኬስትራ ተናቦ መስራት።
ማጠቃለያ፡
እነዚህን እሴቶች በቁርጠኝነት እና በሙያ ስነምግባር ስንተገብር የኮንስትራክሽን ዘርፉ ብቃት ያለውና ተወዳዳሪ በመሆን ለሀገራዊ የምርት ዕድገት ያለው ሚና የጎላ ይሆናል! 🇪🇹
@etconp
❤3🔥2
👉Construction Safety & Compliance Kit – ፕሮፌሽናል Safety Templates ጥቅል ይፈልጋሉ?🦺
📋 Safety Checklists
🗣️ Toolbox Talk Templates
📝 Incident Report Forms
⚠️ JSA Templates
🥾 PPE Inspection Sheets
✅ Editable Word Document👇
https://ye-buna.com/etconp?ref=product_detail&product=6a88471586c15_etconp
📋 Safety Checklists
🗣️ Toolbox Talk Templates
📝 Incident Report Forms
⚠️ JSA Templates
🥾 PPE Inspection Sheets
✅ Editable Word Document👇
https://ye-buna.com/etconp?ref=product_detail&product=6a88471586c15_etconp
❤6🙏2
Procurement-and-property-proclamation-2024-.pdf
1.9 MB
👉አዲሱ የፌዴራል የመንግስት ግዥና ንብረት አስተዳደር አዋጅ ቁጥር 1333/2024
🌟Updated Public Procurement and Property Administration Proclamation No 1333/2024
https://t.me/ETCONpWORK
@etconp
🌟Updated Public Procurement and Property Administration Proclamation No 1333/2024
https://t.me/ETCONpWORK
@etconp
🙏6❤4
👉To speed up the setting time of ready-mix concrete, you add a set accelerator.
🌟Common Chemicals Used as Accelerators
☄Here are the most widely used types:
1. Calcium Chloride (CaCl₂)
Very effective and inexpensive.
Fastest accelerator.
BUT not recommended for reinforced concrete because it increases the risk of steel corrosion.
2. Non-Chloride Accelerators (Safe for Reinforcement)
These are commonly used in structural works:
Calcium Nitrate
Calcium Formate
Calcium Nitrite
Sodium Nitrate
Triethanolamine (TEA) (usually in blended admixtures)
Commercial names include: MasterSet, Set-X, Mapeplast, Sika Rapid, etc.
🗂When to Use Accelerators?
⏺Cold weather concreting (low temperature slows setting)
⏺Early stripping of formwork
⏺Early strength gain needed
⏺Emergency repairs
🚥Important Notes
Dosage must follow the manufacturer’s recommendation (usually 0.5–2% by weight of cement).
✅Too much accelerator causes cracks, flash setting, and reduced strength.
@etconp
🌟Common Chemicals Used as Accelerators
☄Here are the most widely used types:
1. Calcium Chloride (CaCl₂)
Very effective and inexpensive.
Fastest accelerator.
BUT not recommended for reinforced concrete because it increases the risk of steel corrosion.
2. Non-Chloride Accelerators (Safe for Reinforcement)
These are commonly used in structural works:
Calcium Nitrate
Calcium Formate
Calcium Nitrite
Sodium Nitrate
Triethanolamine (TEA) (usually in blended admixtures)
Commercial names include: MasterSet, Set-X, Mapeplast, Sika Rapid, etc.
🗂When to Use Accelerators?
⏺Cold weather concreting (low temperature slows setting)
⏺Early stripping of formwork
⏺Early strength gain needed
⏺Emergency repairs
🚥Important Notes
Dosage must follow the manufacturer’s recommendation (usually 0.5–2% by weight of cement).
✅Too much accelerator causes cracks, flash setting, and reduced strength.
@etconp
❤10🔥1🥰1
👉Construction Safety & Compliance Kit – ፕሮፌሽናል Safety Templates ጥቅል ይፈልጋሉ?🦺
📋 Safety Checklists
🗣️ Toolbox Talk Templates
📝 Incident Report Forms
⚠️ JSA Templates
🥾 PPE Inspection Sheets
✅ Editable Word Document👇
https://ye-buna.com/etconp?ref=product_detail&product=6a88471586c15_etconp
📋 Safety Checklists
🗣️ Toolbox Talk Templates
📝 Incident Report Forms
⚠️ JSA Templates
🥾 PPE Inspection Sheets
✅ Editable Word Document👇
https://ye-buna.com/etconp?ref=product_detail&product=6a88471586c15_etconp
❤5