Ethio Construction Engineering
32.3K subscribers
6.28K photos
359 videos
1.99K files
3.34K links
🔨 World Construction Engineering
Latest updates, tips, and tutorials on building, civil engineering, and construction in World.
Learn, build, and grow with us!

📨 @Philemona7 Or @ETCONpBOT

For Ad:- https://telega.io/c/etconp
Download Telegram
The maximum value of slump for mechanical vibration is ?
1. <25mm
2. 100mm
3. 25mm to 50 mm
4. None
What’s the maximum free fall height of concrete
1. 0.5m
2. 1 meter
3. 1.5 m
4. 2 m
Polar moment of inertia equals to _?
1. Moi=0
2. Moi of x-x , Moi of y-y
3. Moi of x-x *Moi of y-y
4. Moi of x-x + Moi of y-y

Where Moi= moment of inertia
Forwarded from Ethio Construction Engineering (जॉर्डनो ג׳ורדנו ጆርዳኖ جوردانو จอร์แดโน่ JORDANO Ιορδάνοςஜார்டானோ)
This media is not supported in your browser
VIEW IN TELEGRAM
Safe demolition
This media is not supported in your browser
VIEW IN TELEGRAM
Forwarded from Ethio Construction Engineering (Henock)
The FIDIC Forms of Contract, 3rd Ed.pdf
7.1 MB
Forwarded from Ethio Construction Engineering (Bemnetkal)
etabs setup.zip
102 MB
The Dancing House or Fred and Ginger, is the nickname given to the Nationale-Nederlanden building on the Rašínovo nábřeží (Rašín Embankment) in Prague, Czech Republic. It was designed by the Croatian-Czech architect Vlado Milunić in cooperation with Canadian-American architect Frank Gehry on a vacant riverfront plot. The building was designed in 1992 and was completed four years later in 1996.

Prague Czech Republic 🇨🇿

ውብ ምሽት ተመኘን
كنا نتمنى أمسية جميلة
我們希望有一個美麗的夜晚
हमने एक खूबसूरत शाम की कामना की
We wished a beautiful evening
@ETCONp
Cities of the world
ሰናይ ቀን ተመኘን
To determine the l modulus of rupture, the size of test specimen used is
1) 150 x 150 x 500 mm
2) 100 x 100 x 700 mm
3) 150 x 150 x 700 mm
4) 100 x 100 x 500 mm
Forwarded from Ethio Construction Engineering (Henock)
CONSTRUCTION CONTRACTS LAW &amp_ MANAGEMENT.pdf
1.5 MB
Forwarded from Ethio Construction Engineering (Henock)
Civil Code (English).pdf
20.3 MB
👍1
Forwarded from Ethio Construction Engineering (Henock)
Consultant Manual WB 2006.pdf
3 MB
Forwarded from Ethio Construction Engineering (Henock)
FIDIC The Working of DAB.pdf
263.5 KB
Forwarded from Ethio Construction Engineering (Henock)
MDB FIDIC 2006.pdf
266.8 KB
Forwarded from Ethio Construction Engineering (Henock)
forensic engineering.pdf
13.3 MB
Forwarded from Ethio Construction Engineering (Henock)
Building Contract Dictionary.pdf
1.7 MB
Forwarded from Ethio Construction Engineering (Henock)
The FIDIC Forms of Contract, 3rd Ed.pdf
7.1 MB
Mistake or design creativity ?
12 causes of pile foundation failure pile foundation is one of the most popular choices for heavy loaded structures in case s where poor soil conditions are found at a shallow depth . But pile foundation may fail due to different reasons. One must take proper precautions before designing pile foundations so that the possibility of such failure reduces. Causes of failure of pile foundation are given below

1. When the pile load is greater than the design load

2. Poor and defective workmanship while casting the pile

3. Inaccurate determination of the bearing capacity of the pile

4. Corrosion of the timber pile because of assault by insects

5. Bearing pile laying on delicate strata.

6. Defective techniques used while driving the pile

7. Buckling of the pile because of insufficient lateral support

8. Faulty soil investigation

9. Selecting the wrong type of pile

10. Inappropriate characterization of soil

11. Inadequate reinforcement in the pile

12. A decay of piles ( like an attack of insects , corrosion etc. )


https://t.me/ETCONp
❤2