Ethio Construction Engineering
32.3K subscribers
6.28K photos
359 videos
1.99K files
3.34K links
🔨 World Construction Engineering
Latest updates, tips, and tutorials on building, civil engineering, and construction in World.
Learn, build, and grow with us!

📨 @Philemona7 Or @ETCONpBOT

For Ad:- https://telega.io/c/etconp
Download Telegram
👉Today Question @COTMp
.
⏩What is meant by air entrained concrete?
*Why is air content important in concrete?
*Any disadvantages?
▶ Answer ..on discussion
Or 👇👇👇👇👇
▶ @COTMp
👉 TYPES OF BUILDINGS: @COTMp
.
▶Depending upon the character of occupancy or the type of use, building can be classified into different categories as follows:👇
1. RESIDENTIAL BUILDINGS:
These buildings include one or two private dwellings, apartment
houses (flats), hotels, dormitories etc.
.
2. EDUCATIONAL BUILDINGS:
These buildings include any building used for school, college or day
care purposes involving assembly for instruction, education or recreation.
.
3. INSTITUTIONAL BUILDINGS:
These buildings include any building or part which is used for medical treatment etc. Such as Hospitals, nursing homes,
orphanages, sanatoria, jails, prisons, mental hospitals etc.
.
4. ASSEMBLY BUILDINGS:
These buildings may include any building or part of a building where a group of people gathers for recreation, amusement, social, religious or such types of purposes such as theaters, assembly
halls, exhibition halls, restaurants, museum, club rooms, auditoria etc.
.
5. BUSINESS BUILDINGS:
These shall include any building or part of a building which is used for business transactions, keeping records of accounts, town halls,
city halls, court houses etc.
.
6. MERCANTILE BUILDINGS:
These shall include those buildings which are used for soap, market, stores, wholesale or retail.
.
7. INDUSTRIAL BUILDINGS:
This types of building mainly used for manufacturing purposes.
Here products or materials of all kinds and properties are fabricated, assembled or processed, for example, gas plants, refineries, mills, dairies etc.
.
8. STORAGE BUILDINGS:
These buildings are generally used for the storage or sheltering of
goods, wares, or merchandise like warehouses, cold storages,
garages, stables, transit sheds etc.
.
9. HAZARDOUS BUILDINGS:
These buildings include any building which is used for storage, handling, manufacture or processing of highly combustible
explosive materials or products which are liable to burn with extreme rapidly which may produce poisonous fumes, building
which is used for storage, handling or manufacturing highly corrosive, toxic, acid or other liquids or chemicals producing flame, fumes explosive etc.
.
👇👇👇👇👇
Join for more updates via the link below;
t.me/COTMp
👆👆👆👆👆
⚡ አሁኑኑ Join በማረግ እና ለጓደኛዎ እና ለሚያቁት ሁሉ ሼር ያድርጉ።
👉ሸገር ኣዱ ገነት😍
.
🚩ውብ ምሽት ተመኝን @COTMp
⚡👆👆👆👆👆👆👆
👉AUTO CAD SHORT CUTS @COTMp
👉ውድ የ @COTMp ቤተሰቦች ለ ዛሬ ደሞ Beam design ኣዘጋጅተናል👇👇👇
.
✳️ Beam design( flexure) example according to ES EN 1992-1-1: 2015

➡️ Material Data

Concrete grade:- C30/37(fck=30 Mpa).

Steel grade:- S500 ( fyk=500 Mpa).

➡️ Beam geometry

Type:- Simply supported beam

Effective length of beam:- 6 m.

Beam width(b):- 250 mm.

➡️ Load

Dead load(Gk):- self weight of Beam plus 10 KN/m super imposed load.

Live Load(Qk):- 8 KN/m

Depth is not limited by any requirement( singly reinforced beam is possible).
@COTMp 👇
👉Beam section
.
🚩Dimensions in millimeters
👍2
Design Step 1: depth from deflection( deformation) control

👉Since C30/37 concrete is used the limiting span to depth ratio from table 7.4 N Is 14 ( the beam is assumed to be highly stressed with ρ=1.5 %).

👉The limiting depth to prevent excessive deformation is:

👉d=le/14 ....where le is effective length of beam.

👉d=6000 mm/14=428.57 mm

Design step 2:- cover to reinforcement

👉Exposure class is assumed to be XC 1 and the value of Cmin,dur becomes 15 mm.

👉 for separate bar, the value of Cmin,b is equals to the diameter of bar( φ). Assuming φ=20 mm, and Cmin,b=20 mm.

➡️Cₘᵢₙ= max {Cₘᵢₙ,b ; Cₘᵢₙ,dᵤᵣ; 10 mm }

➡️Cₘᵢₙ=max{20 mm,15 mm, 10 mm}

➡️Cₘᵢₙ=20 mm

And the nominal cover becomes

➡️Cnom=Cmin+10=20+10=30 mm cover.

Design step 3:- overall depth

For stirrup assume 8 mm bars.

👉D=d+cover +φₛ+φₗ/2

👉D=428.57mm+30mm+8+20/2=476.57 mm

For ease of construction take D=500 mm ( nearest 50 ).

Design step 4:- Load calculation

Dead load
👉 self weight of beam
Unit weight of concrete(γ)= 25 KN/m³
Weight per meter:-
➡️γ*b*D
➡️25*0.25 *0.5=3.125 KN/m
👉 total dead load

Superimposed+self weight=10KN/m+3.125 KN/m=13.125 KN/M.

Design Load

Pd=1.35Gk+1.5Qk
Pd=1.35*13.125+1.5*8=29.72 KN/m.
.
@COTMp 👇
👍2
👉Beam model with
.
design load @COTMp 👇
Design step 5:-design strength of material

Concrete(fcd)

👉fcd=αcc*fck/γc

👉for C30/37 concrete fck is 30 Mpa.

👉αcc=0.85

👉γc=1.5

👉fcd=(0.85*30/1.5)=17 Mpa

Steel (fyd)

👉fyd=fyk/γs

👉γs=1.15

👉fyd=500/1.15=434.78 Mpa

Design step 6:- design moment calculation

👉 for simply supported beam the maximum moment occurs at mid span and it's vale is

➡️Mmax=Msd=Pd*L²/8

➡️Mmax=Msd=(29.72)*(6²)/8=133.73 KN-m

Design step 6:- check depth for flexure

👉effective depth of beam in order to be singly reinforced is calculated from

✓d=sqrt(Msd/(μsd*fcd*b))

✓Sqrt...[square root of ]
For zero percent redistribution of moment the limiting μsd is 0.295.

d=sqrt({133.73*10⁶}/{0.295*17*250})=326.59 mm

And the provided effective depth:

d= 500 - 30 - 8 - 20/2 = 452 mm

Since the provided depth is greater than calculated from flexure, depth is ok!

Design step 7:- Reinforcement calculation

Using design chart method

✓μsd={Msd*10⁶}/{fcd*b*d²)

✓μsd={133.73*10⁶}/{17*250*452²}=0.154 <0.295 ok!

from design chart the value of kz is

✓kz=0.92

and z( moment arm , the distance between Cc and Ts)

✓Z=kz*d=0.92*452=415.84 mm

Now the amount of reinforcement

✓As={Msd}/{Z*fyd}

✓As={133.73*10⁶}/{415.84*434.77}=739.65 mm²
.
@COTMp 👇
👍1
Design step 8:- check for minimum and maximum longitudinal reinforcement

Minimum reinforcement

✅As,min=0.26{fctm/fyk}bt*d. ( ES EN 1992-1-1:2015 equation 9.1 N)

✅From table 3.1 of ES EN 1992-1-1:2015 the value of fctm for C30/37 concrete is 2.9 Mpa.

👉As,min=0.26*{2.6/500}*250*452=152.776 mm²

👉As> As,min....provide As

Maximum reinforcement

ES EN 1992-1-1:2015 Article 9.2.1.1[3] " the cross sectional area of tension or compression reinforcement should not exceed 0.04Ac" and the national annex recommends the same value.

As,max=0.04*250*500=5000 mm²

As< As,max.....ok!

Design step 9:- calculate the number of bars

👉# of bars=As/as

Where
👉As calculated area of reinforcement

👉as is the area of one bar

👉as=(πφ²/4)=(π*20²/4)≈314 mm²

of bar=(739.65/314)=2.355≈3

🚩provide 3φ20 bars
.
@COTMp ... Finally 👇
👉 beam section detail

➡ All dimensions are in centimetres

➡ The two bars at the top are nominal reinforcement to hang the stirrups( the blue lines).
.
👏THANK YOU @COTMp