It is called a plate load test/ plate bearing test.
Plate load test is used for determining the ultimate bearing capacity of the ground and the likely settlement under a given load.
After backfilling and compacting the built up ground surface with a structural fill material upto the formation level, Plate load test is performed to check the amount of settlement under proposed design load.
A plate diameter of 457mm,loading jack and dial guages are used. A heavy loader machinery is used as a reaction load. An incremental loading and unloading is applyed by a means of a loading jack. A technician will be holding a timer and each loading/unloading will change every 15 mins. The corresponding settlement Is read from a dial gauge. 3 dial gauges at different angles are placed and the average reading from this dial guage is used as a governing reading.
A graph is drawn showing the load vs settlement. The corresponding settlement at the allowable bearing pressure is taken.
The settlement obtained is checked whether it is below the allowable settlement . For instance the allowable settlement for a raft foundation is 75mm.
Note regarding PLT
-performing PLT below a shallow foundation prior to construction is important.
-if the result of test is not satisfactory, all the structural fill material is removed and replaced with another material and compacted again.
- PLT is approximate analysis. It gives bearing capacity of soil upto limited depth only.
The part of report is from our project is shown below and clearly shows settlement vs the load.👷♂️✌
@etconp
Plate load test is used for determining the ultimate bearing capacity of the ground and the likely settlement under a given load.
After backfilling and compacting the built up ground surface with a structural fill material upto the formation level, Plate load test is performed to check the amount of settlement under proposed design load.
A plate diameter of 457mm,loading jack and dial guages are used. A heavy loader machinery is used as a reaction load. An incremental loading and unloading is applyed by a means of a loading jack. A technician will be holding a timer and each loading/unloading will change every 15 mins. The corresponding settlement Is read from a dial gauge. 3 dial gauges at different angles are placed and the average reading from this dial guage is used as a governing reading.
A graph is drawn showing the load vs settlement. The corresponding settlement at the allowable bearing pressure is taken.
The settlement obtained is checked whether it is below the allowable settlement . For instance the allowable settlement for a raft foundation is 75mm.
Note regarding PLT
-performing PLT below a shallow foundation prior to construction is important.
-if the result of test is not satisfactory, all the structural fill material is removed and replaced with another material and compacted again.
- PLT is approximate analysis. It gives bearing capacity of soil upto limited depth only.
The part of report is from our project is shown below and clearly shows settlement vs the load.👷♂️✌
@etconp
👍1
Forwarded from Ethio Construction Engineering
📖✔IMPORTANT POINTS FROM THERNAL STRESSES (STRENGTH_OF_MATERIALS)
✔ Stresses produced due to change in temperatures(Rise/Fall) are called as thermal stresses
✔ Actual meaning of coefficient of thermal expansion is strain produced per unit change in temperature
✔Unit of Coefficient of thermal expansion = per degree celcius
✔ Coefficient of thermal expansion for different materials
✴ Aluminium = 24 x 10^(-6)
✴ Copper = 17.5 x 10^(-6)
✴ Steel = 12 x 10^(-6)
✔Higher the value of coefficient of thermal expansion, more will be the material sensitive for temperature change
✔For the bar free to expand, with change in temperature (rise/fall), no stress is developed
✔Prismatic bar with rigidly supported at both ends
✔ As temperature increases, compressive stresses are developes on bar
✔ As temperature decreases, tensile stresses are developes on bar
✔ Copper bar is in series with steel bar
✔ As temperature increases, compressive stresses are developed on both copper and steel bar
✔ As temperature decreases, tensile stresses are developed on both copper and steel bar
✔ Copper plate is in parallel with steel plate and form a composite
✔ As temperature increases, compressive stress developed on copper and tensile stress developed on steel
✔ As temperature decreases, tensile stress developed on copper and compressive stress developed on steel
✔ Copper rod is enclosed in steel tube and both are rigidly fixed at ends
✔As temperature increases, Compressive stresses are developes on both copper and steel
✔ As temperature decreases, tensile stresses are developes on both copper and steel.
✔ Stresses produced due to change in temperatures(Rise/Fall) are called as thermal stresses
✔ Actual meaning of coefficient of thermal expansion is strain produced per unit change in temperature
✔Unit of Coefficient of thermal expansion = per degree celcius
✔ Coefficient of thermal expansion for different materials
✴ Aluminium = 24 x 10^(-6)
✴ Copper = 17.5 x 10^(-6)
✴ Steel = 12 x 10^(-6)
✔Higher the value of coefficient of thermal expansion, more will be the material sensitive for temperature change
✔For the bar free to expand, with change in temperature (rise/fall), no stress is developed
✔Prismatic bar with rigidly supported at both ends
✔ As temperature increases, compressive stresses are developes on bar
✔ As temperature decreases, tensile stresses are developes on bar
✔ Copper bar is in series with steel bar
✔ As temperature increases, compressive stresses are developed on both copper and steel bar
✔ As temperature decreases, tensile stresses are developed on both copper and steel bar
✔ Copper plate is in parallel with steel plate and form a composite
✔ As temperature increases, compressive stress developed on copper and tensile stress developed on steel
✔ As temperature decreases, tensile stress developed on copper and compressive stress developed on steel
✔ Copper rod is enclosed in steel tube and both are rigidly fixed at ends
✔As temperature increases, Compressive stresses are developes on both copper and steel
✔ As temperature decreases, tensile stresses are developes on both copper and steel.
👍1
Forwarded from 杨柳青
This media is not supported in your browser
VIEW IN TELEGRAM
This media is not supported in your browser
VIEW IN TELEGRAM
This media is not supported in your browser
VIEW IN TELEGRAM
This media is not supported in your browser
VIEW IN TELEGRAM
This media is not supported in your browser
VIEW IN TELEGRAM
This media is not supported in your browser
VIEW IN TELEGRAM
This media is not supported in your browser
VIEW IN TELEGRAM
This media is not supported in your browser
VIEW IN TELEGRAM
This media is not supported in your browser
VIEW IN TELEGRAM
This media is not supported in your browser
VIEW IN TELEGRAM
What is the name of these test performed on a ground surface?
Anonymous Quiz
25%
Cone penetration test
14%
Standard penetration test
52%
Field density test
9%
Plate load tesr
It is called field density test(FDT) using sand replacement method.
There are different methods used to determine the density of a compacted soil. Sand replacement method is one of them.
FDT test is probably the most frequently applied field test in a construction site. Before placing any RC structures( foundation,grade beam, grade slab..) into the ground surface, FDT should be performed and should pass the test.
FDT Is performed to determine the degree of compaction of a ground surface. Degree of compaction is given in a percentile value. As per AASHTO standard, insitu degree of compaction should be more than 95%. This means the on-site soil density must be atleast 95% of the maximum achievable compaction.
This is done first by determining the maximum dry density(MDD) and optimum moisture content(OMC) of the compacted fill material in the laboratory.
Next task is to compare the MDD value with that of the insitu dry density value.
The basic principle of sand replacement method is to measure the insitu volume of hole from which the material was excavated from the weight of sand with known density filling the hole. The insitu density of material is given by the weight of excavated material divided by insitu volume.
The sand replacement method can be a little bit tricky. It will better to check the procedure on a YouTube tutorial.
Note regarding FDT
-Considering a compaction thickness of 25cm,one FDT in every 200m3 should be taken.
- if the FDT failed,then the entire fill material is removed, replaced by another material and again compacted well.
-performing FDT prior to construction Is important in checking the stability of ground surface.
Part of report below from our project shows FDT test result and the obtained degree of compaction.👷♂️✌
@etconp
There are different methods used to determine the density of a compacted soil. Sand replacement method is one of them.
FDT test is probably the most frequently applied field test in a construction site. Before placing any RC structures( foundation,grade beam, grade slab..) into the ground surface, FDT should be performed and should pass the test.
FDT Is performed to determine the degree of compaction of a ground surface. Degree of compaction is given in a percentile value. As per AASHTO standard, insitu degree of compaction should be more than 95%. This means the on-site soil density must be atleast 95% of the maximum achievable compaction.
This is done first by determining the maximum dry density(MDD) and optimum moisture content(OMC) of the compacted fill material in the laboratory.
Next task is to compare the MDD value with that of the insitu dry density value.
The basic principle of sand replacement method is to measure the insitu volume of hole from which the material was excavated from the weight of sand with known density filling the hole. The insitu density of material is given by the weight of excavated material divided by insitu volume.
The sand replacement method can be a little bit tricky. It will better to check the procedure on a YouTube tutorial.
Note regarding FDT
-Considering a compaction thickness of 25cm,one FDT in every 200m3 should be taken.
- if the FDT failed,then the entire fill material is removed, replaced by another material and again compacted well.
-performing FDT prior to construction Is important in checking the stability of ground surface.
Part of report below from our project shows FDT test result and the obtained degree of compaction.👷♂️✌
@etconp