What is the name of these cement concrete placed below any RC structures done on ground surface?
Anonymous Quiz
13%
Cement binding mortar
11%
Reinforced cement concrete
50%
Blinding Plain cement concrete
25%
Floor cement screed
It is called blinding PCC(plain cement concrete)
It is a layer of thin unreinforced concrete placed on the ground to isolate the RC structure above it from the soil below. It also serves to provide a stable, flat surface to launch construction of structures. The blinding PCC helps to fix the formwork for the RC structure.It also serves as some level of damp proof membrane.
Blinding PCC is also used to protect the RC body of foundation from salt attack.
Blinding PCC is one of the first cement concrete poured in construction project for a shallow foundation. It has a thickness from 5-10cm. It won't be above 10cm thickness to avoid shrinkage reinforcement.
Blinding plain Cement concrete are mostly SRC C25/20 concrete.SRC stands for sulphate resisting concrete, to protect against sulphate attacks since it is directly in contact with the soil. C25 is the 28 day compressive strength of the concrete of 25mpa with 1:1:2 ratio. /20 represent the maximum seive size of the crushed aggregate which is 20mm crushed aggregate. The plant trial mix below is from our project and shows the mix design for SRC c25/20 blinding cement concrete.✌👷♂️
@etconp
It is a layer of thin unreinforced concrete placed on the ground to isolate the RC structure above it from the soil below. It also serves to provide a stable, flat surface to launch construction of structures. The blinding PCC helps to fix the formwork for the RC structure.It also serves as some level of damp proof membrane.
Blinding PCC is also used to protect the RC body of foundation from salt attack.
Blinding PCC is one of the first cement concrete poured in construction project for a shallow foundation. It has a thickness from 5-10cm. It won't be above 10cm thickness to avoid shrinkage reinforcement.
Blinding plain Cement concrete are mostly SRC C25/20 concrete.SRC stands for sulphate resisting concrete, to protect against sulphate attacks since it is directly in contact with the soil. C25 is the 28 day compressive strength of the concrete of 25mpa with 1:1:2 ratio. /20 represent the maximum seive size of the crushed aggregate which is 20mm crushed aggregate. The plant trial mix below is from our project and shows the mix design for SRC c25/20 blinding cement concrete.✌👷♂️
@etconp
Forwarded from Ethio Construction Engineering
👉TOP 8 TYPES OF ESTIMATE IN CONSTRUCTION WORKS @COTMp
.
▶Various types of estimates as prepared
are of following types:-
1. Approximate or Preliminary Estimate
The estimate is prepared to know the approximate cost of the work and to take the administrative approval by the competent authority of the department for which the work is to be executed this
estimate is also called as *ROUGH COST ESTIMATE. The cost of building, cost of land, cost of roads etc. are shown separately in this estimate.
The necessity and urgency of the estimate and rates
arrived at for knowing the cost are fully explained in this estimate.
The specifications to be adopted are also fully explained. The rates provided in the estimate and for unit basis i.e., per sq.m for buildings, per km length of road or canal and per running meter of span for culverts and bridges.
2. Plinth Area Estimate
The estimate prepared on the plinth area basis of the building by using suitable
plinth area rates is called the plinth area estimate. The area of the building at the plinth level, by taking the external dimensions is worked out and is multiplied by suitable rate per sq m. The cost thus arrived at is the cost of
building based on plinth area. The plinth area rates for different types of buildings are different i.e., the rates for residential
buildings are less than the rates for the hospital buildings etc. Plinth area
estimate is also a rough cost estimate.
3. Cubical Content Estimate This estimate is also an approximate and
is prepared on the basis of cubical contents of the building. The cost of the
building is calculated by multiplying the plinth area by the height of building and cubical content rate i.e., plinth area multiplied by; height multiplied by;
cubical content rate. The plinth area is calculated as staved above and the
height is taken from the top of flat roof (or halfway of the sloped roof) to the top of concrete in foundation. The cubical
content rate is deduced from the cost of similar building in the locality. The
parapet is not taken in the calculations.
*This estimate is more accurate than the
plinth area estimate.
4. Detailed Estimate
After obtaining the administrative
approval of the concerned department against the rough cost estimate.
As this estimate is based on the plans and sections of the building so
it is the most accurate estimate. The quantities of items under various sub
heads of work are calculated from the drawings and cost of each item is worked out separately according to the prevalent market rates and is totaled. After doing the total of all items
a percentage of 3 to 5 is added for unforeseen items, change of design and provision of petty-establishment. Grand
total so obtained gives the estimated cost of building. This estimate is then
submitted to the competent authority for
according technical sanction.
The detailed estimate is accompanied by report,
design and scope, detailed drawings, detailed specifications, justification of the rates provided and the limit for execution
of the work. The work us executed according to the detailed estimate.
5. Revised Estimate
When the cost of the estimate exceeds
or likely to increase by 10% or more, a revised estimate is required to be
prepared.
It is accompanied by the
comparative statement showing the variations of each item of work and
giving the reasons of excess.
6. Supplementary Estimate
When some addition to the original work is made a fresh detailed estimate for the additional work is prepared to supplement the original estimate
7. Annual Repair of Annual Maintenance Estimate This estimate is prepared to carry out annual repairs or maintenance.
8. Extension and Improvement Estimate
When some changes and extensions are required to be made in the old work, the cost of which cannot be met by the annual repair/maintenance estimate, a detailed estimate is prepared for such work which is called as Extension and Improvement estimate.
.
🚩ሼር በማድረግ ለወዳጅዎ ያጋሩ። እናመሰግናለን።
.
▶Various types of estimates as prepared
are of following types:-
1. Approximate or Preliminary Estimate
The estimate is prepared to know the approximate cost of the work and to take the administrative approval by the competent authority of the department for which the work is to be executed this
estimate is also called as *ROUGH COST ESTIMATE. The cost of building, cost of land, cost of roads etc. are shown separately in this estimate.
The necessity and urgency of the estimate and rates
arrived at for knowing the cost are fully explained in this estimate.
The specifications to be adopted are also fully explained. The rates provided in the estimate and for unit basis i.e., per sq.m for buildings, per km length of road or canal and per running meter of span for culverts and bridges.
2. Plinth Area Estimate
The estimate prepared on the plinth area basis of the building by using suitable
plinth area rates is called the plinth area estimate. The area of the building at the plinth level, by taking the external dimensions is worked out and is multiplied by suitable rate per sq m. The cost thus arrived at is the cost of
building based on plinth area. The plinth area rates for different types of buildings are different i.e., the rates for residential
buildings are less than the rates for the hospital buildings etc. Plinth area
estimate is also a rough cost estimate.
3. Cubical Content Estimate This estimate is also an approximate and
is prepared on the basis of cubical contents of the building. The cost of the
building is calculated by multiplying the plinth area by the height of building and cubical content rate i.e., plinth area multiplied by; height multiplied by;
cubical content rate. The plinth area is calculated as staved above and the
height is taken from the top of flat roof (or halfway of the sloped roof) to the top of concrete in foundation. The cubical
content rate is deduced from the cost of similar building in the locality. The
parapet is not taken in the calculations.
*This estimate is more accurate than the
plinth area estimate.
4. Detailed Estimate
After obtaining the administrative
approval of the concerned department against the rough cost estimate.
As this estimate is based on the plans and sections of the building so
it is the most accurate estimate. The quantities of items under various sub
heads of work are calculated from the drawings and cost of each item is worked out separately according to the prevalent market rates and is totaled. After doing the total of all items
a percentage of 3 to 5 is added for unforeseen items, change of design and provision of petty-establishment. Grand
total so obtained gives the estimated cost of building. This estimate is then
submitted to the competent authority for
according technical sanction.
The detailed estimate is accompanied by report,
design and scope, detailed drawings, detailed specifications, justification of the rates provided and the limit for execution
of the work. The work us executed according to the detailed estimate.
5. Revised Estimate
When the cost of the estimate exceeds
or likely to increase by 10% or more, a revised estimate is required to be
prepared.
It is accompanied by the
comparative statement showing the variations of each item of work and
giving the reasons of excess.
6. Supplementary Estimate
When some addition to the original work is made a fresh detailed estimate for the additional work is prepared to supplement the original estimate
7. Annual Repair of Annual Maintenance Estimate This estimate is prepared to carry out annual repairs or maintenance.
8. Extension and Improvement Estimate
When some changes and extensions are required to be made in the old work, the cost of which cannot be met by the annual repair/maintenance estimate, a detailed estimate is prepared for such work which is called as Extension and Improvement estimate.
.
🚩ሼር በማድረግ ለወዳጅዎ ያጋሩ። እናመሰግናለን።
Forwarded from Ethio Construction Engineering
👉PROPERTIES OF HARDENED CONCRETE @COTMp
.
▶The following are the properties of concrete
in its hardened state, used by the designer
during design process of reinforced concrete structure.
1. COMPRESSIVE STRENGTH
The characteristics strength is defined as
the strength of concrete below which not
more than 5% of the test results are expected to fall. As per IS: 456 concrete
mix always designed for the target strength
computed as,*Target strength: Characteristics strength + (1.65 x standard deviation) C-20 is the minimum grade of concrete for
use in RCC work.
2. TENSILE STRENGTH
Flexural strength is one measure of the
Tensile strength of concrete. In concrete
structure one set of visible cracks occur under flexure to compute load factor
against cracking .
According to IS: 456 the
tensile strength of concrete can be
computed from the compressive strength
using empirical relation given by:
Flexural strength: f =0.7√fck N/mm
3. MODULUS ELASTICITY
Modulus of elasticity of concrete which is
significantly influenced by the following
factors.
*Type of the aggregates used
*Type of cement and
*Mix proportions
***This property is required for the computations of deflections of strutural
concrete members which forms an
important limit state in the design of concrete members. In the absence of test data, the modulus of elasticity of concrete
is normally related to the compressive strength and is computed by the empirical relation recommended by IS: 456-2000 code and is expressed as,
E =5000√fck
Where E is the short term static modulus
of elasticity of concrete expressed in N/
mm
f is the characteristic compressive
strength of concrete expressed in N/mm .
4. SHRINKAGE OF CONCRETE
The ingredients of concrete and
environmental conditions like temperature
and humidity influence the total shrinkage
of concrete. Water content in concrete
significantly affects the shrinkage. The IS:
456-2000 recommends the total shrinkage
strain as 0.0003 in the absence of test
data. Drying shrinkage in plain concrete
may result in surface cracks. Shrinkage of
concrete also influences the deflections of
reinforced concrete members.
5. CREEP OF CONCRETE
The inelastic time dependent strain
developed in a concrete emeber under
sustained loading is refered to as creep of
concrete. Creep of concrete is influenced
by following factors.
Cement content,
W/C ratio,
Temperature and humidity,
Size of structural element,
Type of loading and period of loading.
In the absence of reliable experimental
data, the creep coefficient is expressed as
the ratio of ultimate creep strain/elastic
strain at various ages of loading as
recommended by IS: 456-2000 are given
below.
Age at Loading Creep Coefficient
7 days 2.2
28 days 1.6
1 year 1.1
Creep of concrete significantly affects the
deflections of reinforced concrete flexural
members. Higher creep coefficient results
in large deflections. The value of creep
coefficient is useful in the computation of
time dependent deflections in reinforced
concrete members.
6. COEFFICIENT OF THERMAL
EXPANSION
The coefficient of thermal expansion of
concrete, influenced mainly by the type of
aggregate used in concrete is required for
the design of structures like chimneys,
water tanks, silos etc.
.
🚩SHARE SHARE SHARE
.
▶The following are the properties of concrete
in its hardened state, used by the designer
during design process of reinforced concrete structure.
1. COMPRESSIVE STRENGTH
The characteristics strength is defined as
the strength of concrete below which not
more than 5% of the test results are expected to fall. As per IS: 456 concrete
mix always designed for the target strength
computed as,*Target strength: Characteristics strength + (1.65 x standard deviation) C-20 is the minimum grade of concrete for
use in RCC work.
2. TENSILE STRENGTH
Flexural strength is one measure of the
Tensile strength of concrete. In concrete
structure one set of visible cracks occur under flexure to compute load factor
against cracking .
According to IS: 456 the
tensile strength of concrete can be
computed from the compressive strength
using empirical relation given by:
Flexural strength: f =0.7√fck N/mm
3. MODULUS ELASTICITY
Modulus of elasticity of concrete which is
significantly influenced by the following
factors.
*Type of the aggregates used
*Type of cement and
*Mix proportions
***This property is required for the computations of deflections of strutural
concrete members which forms an
important limit state in the design of concrete members. In the absence of test data, the modulus of elasticity of concrete
is normally related to the compressive strength and is computed by the empirical relation recommended by IS: 456-2000 code and is expressed as,
E =5000√fck
Where E is the short term static modulus
of elasticity of concrete expressed in N/
mm
f is the characteristic compressive
strength of concrete expressed in N/mm .
4. SHRINKAGE OF CONCRETE
The ingredients of concrete and
environmental conditions like temperature
and humidity influence the total shrinkage
of concrete. Water content in concrete
significantly affects the shrinkage. The IS:
456-2000 recommends the total shrinkage
strain as 0.0003 in the absence of test
data. Drying shrinkage in plain concrete
may result in surface cracks. Shrinkage of
concrete also influences the deflections of
reinforced concrete members.
5. CREEP OF CONCRETE
The inelastic time dependent strain
developed in a concrete emeber under
sustained loading is refered to as creep of
concrete. Creep of concrete is influenced
by following factors.
Cement content,
W/C ratio,
Temperature and humidity,
Size of structural element,
Type of loading and period of loading.
In the absence of reliable experimental
data, the creep coefficient is expressed as
the ratio of ultimate creep strain/elastic
strain at various ages of loading as
recommended by IS: 456-2000 are given
below.
Age at Loading Creep Coefficient
7 days 2.2
28 days 1.6
1 year 1.1
Creep of concrete significantly affects the
deflections of reinforced concrete flexural
members. Higher creep coefficient results
in large deflections. The value of creep
coefficient is useful in the computation of
time dependent deflections in reinforced
concrete members.
6. COEFFICIENT OF THERMAL
EXPANSION
The coefficient of thermal expansion of
concrete, influenced mainly by the type of
aggregate used in concrete is required for
the design of structures like chimneys,
water tanks, silos etc.
.
🚩SHARE SHARE SHARE
👍1
What is the name of this material??
Anonymous Quiz
12%
A) Cover block
55%
B) spacer block
30%
C) A and B
3%
D) hollow block
It is called cover block or spacer block. Both serves the same purpose.
Cover blocks which is also known as Spacer blocks are small concrete blocks that are used to support the reinforcement bars and to keep it from touching the internal surface of the shuttering.
The purpose of cover block is to ensure proper concrete cover is provided to the reinforcement bar so that it is not seen from outside and is protected from corrosion.
Cover blocks are placed on the bottom and sides of RC structures.
The thickness of the concrete cover is different for substructure RC structures and for superstructure RC structures. The thickness is also different for different RC structures. For instance the cover block thickness for beams is not the same as for slabs. The cover slab thickness for different structures depends on the project specifications.
A concrete grade for cover block is similar to that used on the reinforced concrete .mostly a C25 concrete grade is used. The compressive strength of the cover block has to be tested before placing it on the site.
Cover blocks can easily be done on site by using PVC pipes Or precast concrete blocks are also available on the market .
The file below is from our project and clearly shows the thickness of cover blocks for different RC structures.
For instance
-superstructure columns= 40mm
- neck column(substructure columns)=50mm ✌👷♂️
@etconp
Cover blocks which is also known as Spacer blocks are small concrete blocks that are used to support the reinforcement bars and to keep it from touching the internal surface of the shuttering.
The purpose of cover block is to ensure proper concrete cover is provided to the reinforcement bar so that it is not seen from outside and is protected from corrosion.
Cover blocks are placed on the bottom and sides of RC structures.
The thickness of the concrete cover is different for substructure RC structures and for superstructure RC structures. The thickness is also different for different RC structures. For instance the cover block thickness for beams is not the same as for slabs. The cover slab thickness for different structures depends on the project specifications.
A concrete grade for cover block is similar to that used on the reinforced concrete .mostly a C25 concrete grade is used. The compressive strength of the cover block has to be tested before placing it on the site.
Cover blocks can easily be done on site by using PVC pipes Or precast concrete blocks are also available on the market .
The file below is from our project and clearly shows the thickness of cover blocks for different RC structures.
For instance
-superstructure columns= 40mm
- neck column(substructure columns)=50mm ✌👷♂️
@etconp
👉PROPERTIES OF AGGREGATES FOR CONCRETE @COTMp
.
▶Approximately 75% of the volume of concrete is occupied by aggregates,so
quality of aggregates plays an important role in determining properties of concrete.
*Aggregates come in various shapes, sizes, and materials ranging from fine particles of sand to large, coarse rocks. *Natural aggregates are formed by process of weathering and abrasion or by artificially crushing large parent mass.
Because cement is the most expensive ingredient in making concrete, it is
desirable to minimize the amount of cement used. 70 to 80% of the volume of
concrete is aggregate in order to keep the cost of the concrete low.
*Soft, porous aggregates can result in weak concrete with low wear resistance, while using hard aggregates can make strong concrete with a high resistance to abrasion.
*Aggregates are of two basic types: Coarse: crushed rock, gravel or screenings.
*Fine: fine and coarse sands and crusher fines Aggregates should be clean, hard, and strong.
*The aggregate is usually washed to remove any dust, silt, clay, organic matter, or other impurities that would interfere with
the bonding reaction with the cement paste.
*The choice of aggregate is determined by the proposed use of the concrete.
*Normally sand, gravel, and crushed stone are used as aggregates to make concrete.
*The aggregate should be well-graded to improve packing efficiency and minimize the amount of cement paste needed. Also, this makes the concrete more workable.
Some of the important properties of aggregates are discussed below.
▶PROPERTIES OF AGGREGATES
1. SOUNDNESS:Rocks that undergo volume changes due to wetting and drying are rare. However, aggregate is susceptible to volume change during freezing and thawing cycles.
*Freezing can cause internal stresses to build up as water inside the aggregate freezes and expands.
2. WEAR RESISTANCE
A good aggregate will be hard, dense, strong, and
free of porous material. The abrasion resistance of
aggregate can be tested by the Los Angeles abrasion test; however, this test does not match
well with concrete wear in the field.
3. ALKALI-AGGREGATE
REACTION: An expansive reaction between some reactive forms of silica with the aggregate and alkalis in the cement paste.
*The result is overall cracking in the
structure, manifesting itself in map or pattern cracking at the surface. *This reaction can be
controlled most easily by using low-alkali cements.
However, due to changes in manufacturing, low-
alkali cements may not be feasible.
*A better approach is to avoid aggregate with the potential or proven record of reactivity. A low w/c ratio is very impermeable and will slow down the reaction but not stop it. No adverse reactions will occur without external water.
4. OTHER ALKALI-SILICA
REACTIONS: Sand-gravels found in river systems of Kansas and Nebraska are highly reactive and cause map cracking. *Replacement of 30% of the aggregate with
crushed limestone is effective in reducing the damage. Basically, it results in the separation of flat clay minerals causing very slow expansion.
5. ALKALI-CARBONATE REACTIONS: An expansive reaction involving clayey
carbonate rock. Reaction can be controlled by using low-alkali cements or blending aggregate with other less reactive material.
*ASTM has set standards for deleterious substances in aggregates, which depend on application.
6. IMPURITIES: Solid materials – particles passing a 200- mesh sieve.
*These fine particles may increase water requirements and interfere with surface bonding
between cement and coarse aggregates.
Soluble substances –organic matter may interfere chemically with alkaline cement pastes affecting setting time. *Aggregates obtained from the sea should be thoroughly cleaned
to avoid problems from salt contamination.
7. UNSOUND PARTICLES
Soft particles such as clay lumps, wood, and coal
will cause pitting and scaling at the surface.
Organic compounds can be released which interfere
with setting and hardening. Weak material of low density which have low wear resistance should also be avoided.
https://telegram.me/COTMp
.
▶Approximately 75% of the volume of concrete is occupied by aggregates,so
quality of aggregates plays an important role in determining properties of concrete.
*Aggregates come in various shapes, sizes, and materials ranging from fine particles of sand to large, coarse rocks. *Natural aggregates are formed by process of weathering and abrasion or by artificially crushing large parent mass.
Because cement is the most expensive ingredient in making concrete, it is
desirable to minimize the amount of cement used. 70 to 80% of the volume of
concrete is aggregate in order to keep the cost of the concrete low.
*Soft, porous aggregates can result in weak concrete with low wear resistance, while using hard aggregates can make strong concrete with a high resistance to abrasion.
*Aggregates are of two basic types: Coarse: crushed rock, gravel or screenings.
*Fine: fine and coarse sands and crusher fines Aggregates should be clean, hard, and strong.
*The aggregate is usually washed to remove any dust, silt, clay, organic matter, or other impurities that would interfere with
the bonding reaction with the cement paste.
*The choice of aggregate is determined by the proposed use of the concrete.
*Normally sand, gravel, and crushed stone are used as aggregates to make concrete.
*The aggregate should be well-graded to improve packing efficiency and minimize the amount of cement paste needed. Also, this makes the concrete more workable.
Some of the important properties of aggregates are discussed below.
▶PROPERTIES OF AGGREGATES
1. SOUNDNESS:Rocks that undergo volume changes due to wetting and drying are rare. However, aggregate is susceptible to volume change during freezing and thawing cycles.
*Freezing can cause internal stresses to build up as water inside the aggregate freezes and expands.
2. WEAR RESISTANCE
A good aggregate will be hard, dense, strong, and
free of porous material. The abrasion resistance of
aggregate can be tested by the Los Angeles abrasion test; however, this test does not match
well with concrete wear in the field.
3. ALKALI-AGGREGATE
REACTION: An expansive reaction between some reactive forms of silica with the aggregate and alkalis in the cement paste.
*The result is overall cracking in the
structure, manifesting itself in map or pattern cracking at the surface. *This reaction can be
controlled most easily by using low-alkali cements.
However, due to changes in manufacturing, low-
alkali cements may not be feasible.
*A better approach is to avoid aggregate with the potential or proven record of reactivity. A low w/c ratio is very impermeable and will slow down the reaction but not stop it. No adverse reactions will occur without external water.
4. OTHER ALKALI-SILICA
REACTIONS: Sand-gravels found in river systems of Kansas and Nebraska are highly reactive and cause map cracking. *Replacement of 30% of the aggregate with
crushed limestone is effective in reducing the damage. Basically, it results in the separation of flat clay minerals causing very slow expansion.
5. ALKALI-CARBONATE REACTIONS: An expansive reaction involving clayey
carbonate rock. Reaction can be controlled by using low-alkali cements or blending aggregate with other less reactive material.
*ASTM has set standards for deleterious substances in aggregates, which depend on application.
6. IMPURITIES: Solid materials – particles passing a 200- mesh sieve.
*These fine particles may increase water requirements and interfere with surface bonding
between cement and coarse aggregates.
Soluble substances –organic matter may interfere chemically with alkaline cement pastes affecting setting time. *Aggregates obtained from the sea should be thoroughly cleaned
to avoid problems from salt contamination.
7. UNSOUND PARTICLES
Soft particles such as clay lumps, wood, and coal
will cause pitting and scaling at the surface.
Organic compounds can be released which interfere
with setting and hardening. Weak material of low density which have low wear resistance should also be avoided.
https://telegram.me/COTMp
Telegram
ETCONp Discussion
✌️ይህ የ @etconp መወያያ ግሩፓቹ ነው።
✋This is discussion group of @ETCONpWORK
.
🔖ማሳሰብያ ...
.
⚡️ግሩፑ ላይ ማነኛውም ከ ኮንስትራክሽን ጉዳዮች ውጪ መለጠፍ በፍፁም አይፈቀድም!
.
📩ለማነኛውም ሀሳብ እና አስተያየት @ETCONpBOT ፃፉልን። እናመሰግናለን🙏
✋This is discussion group of @ETCONpWORK
.
🔖ማሳሰብያ ...
.
⚡️ግሩፑ ላይ ማነኛውም ከ ኮንስትራክሽን ጉዳዮች ውጪ መለጠፍ በፍፁም አይፈቀድም!
.
📩ለማነኛውም ሀሳብ እና አስተያየት @ETCONpBOT ፃፉልን። እናመሰግናለን🙏
👍2
What is the name of this test performed on a fresh concrete??
Anonymous Quiz
9%
Compressive strength of concrete
5%
Water absorption test of concrete
1%
Temperature test of concrete
84%
Slump test of concrete
It is called concrete slump test
Slump test is one of the most important concrete quality control test done on site. Slump test is the measure of consistency of a fresh concrete. It is performed to
check the workability of the concrete.
Slump test gives you an idea of how workable the concrete is and the easiness to cast the concrete on the site without affect the strength of the concrete .
Concrete check point will be prepared on site and every concrete mixer truck which arrives on site shall be checked for the Slump test value before casting.
Cone shaped metallic mould, bottom diameter 20cm and top diameter 10cm and height of 30cm is used. A tamping rod is used for tapping in the concrete into the mould.
Different concrete types at different concrete casting location have different pass Slump values.As per project specifications and trial mix design, different Slump value might be placed. As per our project concrete trial mix design:
MSRC,GGBS RC Substructures...200±40 mm
OPC RC Superstructures.. 200±40 mm
SRC Blinding PCC ..125±25 mm
OPC structural topping... 125±25 mm
✌👷♂️
Slump test is one of the most important concrete quality control test done on site. Slump test is the measure of consistency of a fresh concrete. It is performed to
check the workability of the concrete.
Slump test gives you an idea of how workable the concrete is and the easiness to cast the concrete on the site without affect the strength of the concrete .
Concrete check point will be prepared on site and every concrete mixer truck which arrives on site shall be checked for the Slump test value before casting.
Cone shaped metallic mould, bottom diameter 20cm and top diameter 10cm and height of 30cm is used. A tamping rod is used for tapping in the concrete into the mould.
Different concrete types at different concrete casting location have different pass Slump values.As per project specifications and trial mix design, different Slump value might be placed. As per our project concrete trial mix design:
MSRC,GGBS RC Substructures...200±40 mm
OPC RC Superstructures.. 200±40 mm
SRC Blinding PCC ..125±25 mm
OPC structural topping... 125±25 mm
✌👷♂️
❤1👍1
What is the name of this paint on a foundation structures??
Anonymous Quiz
9%
Anti mould paint
22%
Anti termite paint
65%
Bitumen waterproofing paint
4%
Anti fungal paint
Forwarded from Ethio Construction Engineering
👉Morning Lecture @COTMp
.
*Different Ingredients of Cement-Their Proportion,
Functions and Limitations
The Ordinary Portland cement contains different
ingredients with varied proportions. Each ingredients
imparts different property to the cement. To
produce good quality of cement, we must know the
proportions, functions and limitations of different
ingredients of cement.
Proportion of Ingredients of Cement
Different ingredients of cement and their proportions
are as follows:
1. Lime (CaO)
2. Silica (SiO )
3. Alumina(Al O )
4. Iron (Fe O )
5. Magnesia (MgO)
6. Calcium sulfate (CaSO )
7. Sulfur (SO )
8. Alkalis
Functions and Limitations of Cement Ingredients
1. Lime (CaO)
Lime or calcium oxide is the most important
ingredient of cement. The cement contains 60 to
67% of lime in it. It is obtained from limestone,
chalk, shale etc. Adequate quantity of lime in
cement is helpful to form the silicates and
aluminates of calcium.
If lime is added in excess quantity the cement
becomes unsound as well as expansion and
disintegration of cement will occur.
If lime content is lower than the minimum
requirement strength of cement will reduce and also
setting time of cement will decrease.
2. Silica
Silica or silicon dioxide is the second largest
quantity of cement ingredients which is about 17 to
25%. Silica can be obtained from sand, argillaceous
rock etc. Sufficient quantity of silica helps for the
formation of di-calcium and tri-calcium silicates
which imparts strength to the cement.
Excess silica in cement will increase the strength of
cement but at the same time setting time of
cement also increased.
3. Alumina (Al O )
Alumina in cement is present in the form of
aluminum oxide. The range of alumina in cement
should be 3 to 8%. It is obtained from bauxite,
alumina contain clay etc. Alumina imparts quick
setting property to the cement.
In general, high temperature is required to produce
required quality of cement. But alumina when added
with cement ingredients it behaves as a flux and
reduces the clinkering temperature which finally
weakens the cement. So, to maintain the high
temperature alumina should not be used in excess
quantity.
4. Iron oxide (Fe O )
Iron oxide quantity in cement is ranges from 0.5 to
6%.It can be obtained from fly ash, iron ore, scrap
iron etc. The main function of iron oxide is to
impart color to the cement.
At high temperatures, Iron oxide forms tricalcium
aluminoferrite by reacting with aluminum and
calcium. The resultant product imparts the strength
and hardness properties to the cement.
5. Magnesia (MgO)
Cement contains Magnesia or Magnesium oxide in
the range of 0.1 to 3%. Magnesia in cement in
small quantities imparts hardness and color to the
cement.
If it is more than 3%, the cement becomes unsound
and also strength of the cement reduces.
6. Calcium sulfate (CaSO )
Calcium sulfate is present in the form of gypsum in
the cement. It is found together with limestone. It
ranges between 1 to 3%.
The function of calcium sulfate in cement is to
increase the initial setting time of cement.
7. Sulfur (SO )
Sulfur or sulfur trioxide in the cement is about 1 to
3%. Its function is to make the cement sound. If it
is in excess quantity the cement becomes unsound.
8. Alkalis
Alkalis like soda and potash are present in the
cement which normally ranges from 0.1 to 1%.
During manufacturing process of cement most of
the alkalis are carried away by the flue gases at the time of heating. Hence cement contains very small quantities of alkalis in it.
If alkalis content is more than 1% then it will cause
several problems like alkali aggregate reaction,
efflorescence, staining etc.
.
👇👇👇👇👇
Join for more updates via the link below;
t.me/COTMp
👆👆👆👆👆
⚡ አሁኑኑ Join በማረግ እና ለጓደኛዎ እና ለሚያቁት ሁሉ ሼር ያድርጉ።
.
*Different Ingredients of Cement-Their Proportion,
Functions and Limitations
The Ordinary Portland cement contains different
ingredients with varied proportions. Each ingredients
imparts different property to the cement. To
produce good quality of cement, we must know the
proportions, functions and limitations of different
ingredients of cement.
Proportion of Ingredients of Cement
Different ingredients of cement and their proportions
are as follows:
1. Lime (CaO)
2. Silica (SiO )
3. Alumina(Al O )
4. Iron (Fe O )
5. Magnesia (MgO)
6. Calcium sulfate (CaSO )
7. Sulfur (SO )
8. Alkalis
Functions and Limitations of Cement Ingredients
1. Lime (CaO)
Lime or calcium oxide is the most important
ingredient of cement. The cement contains 60 to
67% of lime in it. It is obtained from limestone,
chalk, shale etc. Adequate quantity of lime in
cement is helpful to form the silicates and
aluminates of calcium.
If lime is added in excess quantity the cement
becomes unsound as well as expansion and
disintegration of cement will occur.
If lime content is lower than the minimum
requirement strength of cement will reduce and also
setting time of cement will decrease.
2. Silica
Silica or silicon dioxide is the second largest
quantity of cement ingredients which is about 17 to
25%. Silica can be obtained from sand, argillaceous
rock etc. Sufficient quantity of silica helps for the
formation of di-calcium and tri-calcium silicates
which imparts strength to the cement.
Excess silica in cement will increase the strength of
cement but at the same time setting time of
cement also increased.
3. Alumina (Al O )
Alumina in cement is present in the form of
aluminum oxide. The range of alumina in cement
should be 3 to 8%. It is obtained from bauxite,
alumina contain clay etc. Alumina imparts quick
setting property to the cement.
In general, high temperature is required to produce
required quality of cement. But alumina when added
with cement ingredients it behaves as a flux and
reduces the clinkering temperature which finally
weakens the cement. So, to maintain the high
temperature alumina should not be used in excess
quantity.
4. Iron oxide (Fe O )
Iron oxide quantity in cement is ranges from 0.5 to
6%.It can be obtained from fly ash, iron ore, scrap
iron etc. The main function of iron oxide is to
impart color to the cement.
At high temperatures, Iron oxide forms tricalcium
aluminoferrite by reacting with aluminum and
calcium. The resultant product imparts the strength
and hardness properties to the cement.
5. Magnesia (MgO)
Cement contains Magnesia or Magnesium oxide in
the range of 0.1 to 3%. Magnesia in cement in
small quantities imparts hardness and color to the
cement.
If it is more than 3%, the cement becomes unsound
and also strength of the cement reduces.
6. Calcium sulfate (CaSO )
Calcium sulfate is present in the form of gypsum in
the cement. It is found together with limestone. It
ranges between 1 to 3%.
The function of calcium sulfate in cement is to
increase the initial setting time of cement.
7. Sulfur (SO )
Sulfur or sulfur trioxide in the cement is about 1 to
3%. Its function is to make the cement sound. If it
is in excess quantity the cement becomes unsound.
8. Alkalis
Alkalis like soda and potash are present in the
cement which normally ranges from 0.1 to 1%.
During manufacturing process of cement most of
the alkalis are carried away by the flue gases at the time of heating. Hence cement contains very small quantities of alkalis in it.
If alkalis content is more than 1% then it will cause
several problems like alkali aggregate reaction,
efflorescence, staining etc.
.
👇👇👇👇👇
Join for more updates via the link below;
t.me/COTMp
👆👆👆👆👆
⚡ አሁኑኑ Join በማረግ እና ለጓደኛዎ እና ለሚያቁት ሁሉ ሼር ያድርጉ።
Telegram
ETCONp Discussion
📩ለማነኛውም ሀሳብ እና አስተያየት @Philemona7
✌️ይህ የ @etconp መወያያ ግሩፓቹ ነው።
✋This is discussion group of @ETCONpWORK
.
🔖ማሳሰብያ ...
.
⚡️ግሩፑ ላይ ማነኛውም ከ ኮንስትራክሽን ጉዳዮች ውጪ መለጠፍ በፍፁም አይፈቀድም!
@ETCONpBOT ፃፉልን እናመሰግናለን🙏
✌️ይህ የ @etconp መወያያ ግሩፓቹ ነው።
✋This is discussion group of @ETCONpWORK
.
🔖ማሳሰብያ ...
.
⚡️ግሩፑ ላይ ማነኛውም ከ ኮንስትራክሽን ጉዳዮች ውጪ መለጠፍ በፍፁም አይፈቀድም!
@ETCONpBOT ፃፉልን እናመሰግናለን🙏
👍1